An automatic determination of caffeine in soft drinks using flow injection system with amperometric detection

被引:0
|
作者
Lima, JLFC [1 ]
Delerue-Matos, C [1 ]
Nouws, HPA [1 ]
Vaz, MCVF [1 ]
机构
[1] Univ Porto, Fac Farm, Dept Quim Fis, CEQUP, P-4050 Porto, Portugal
来源
FOOD ADDITIVES AND CONTAMINANTS | 1998年 / 15卷 / 03期
关键词
caffeine; flow injection analysis; amperometric detection; soft drinks;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
An automatic procedure based on a flow injection analysis manifold has been developed for the determination of caffeine in soft drinks using amperometric detection (+1.70 V vs AgCl/Ag). The sample and standards were injected without pre-treatment, with a sampling rate of 120 determinations per hour. The determination of caffeine in several soft drinks available in Portugal using the developed automatic system provided results with mean recovery values between 98% and 103% and a mean standard deviation between 2% and 5%. The results obtained were compared with those given by the reference method recommended by AOAC. Relative deviation was always less than 4%. Reproducibility of the method was assessed by the relative standard deviation (RSD%), values of which were less than 2%.
引用
收藏
页码:265 / 269
页数:5
相关论文
共 50 条
  • [21] Voltammetric Determination of Tumor Biomarkers using Flow Injection Analysis with Amperometric Detection
    Makrlikova, Anna
    Matysik, Frank-Michael
    Navratil, Tomas.
    Barek, Jiri
    Vyskocil, Vlastimil
    PROCEEDINGS OF THE 13TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2017, : 7 - 11
  • [22] DETERMINATION OF CAFFEINE IN SOFT DRINKS AND CAFFEINE-CONTAINING FOOD PREPARATIONS
    FRISCHKORN, CGB
    FRISCHKORN, HE
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1975, 158 (05): : 295 - 299
  • [23] VOLTAMMETRIC DETERMINATION OF CAFFEINE IN COFFEE, TEA, AND SOFT DRINKS
    SONTAG, G
    KRAL, K
    MIKROCHIMICA ACTA, 1979, 1 (3-4) : 229 - 240
  • [24] HPLC determination of caffeine in soft drinks and coffee.
    Eidson, K
    Seebach, GL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 215 : U203 - U203
  • [25] Determination of S-perindopril using a flow injection system with an amperometric biosensor
    Stefan, RI
    van Staden, JKF
    Aboul-Enein, HY
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (03) : 261 - 265
  • [26] Determination of chlorine ions in raw milk by pulsed amperometric detection in a flow injection system
    Chen, Xingguang
    Chu, Beibei
    Xi, Huiting
    Xu, Junjun
    Lai, Lizhi
    Peng, Huifeng
    Deng, Danwen
    Huang, Ganhui
    JOURNAL OF DAIRY SCIENCE, 2018, 101 (11) : 9647 - 9658
  • [27] Flow injection determination of sialic acid based on amperometric detection
    Marzouk, Sayed A. M.
    Haddow, Jody D.
    Amin, Amr
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) : 647 - 653
  • [28] Determination of esterase activity by flow injection analysis with amperometric detection
    Takamura, K
    Fuse, T
    Kusu, F
    ANALYTICAL SCIENCES, 1996, 12 (02) : 343 - 347
  • [29] DETERMINATION OF BROMAZEPAM BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    ZAROBE, ER
    BLANCO, MH
    ABAD, EL
    HERNANDEZ, YL
    ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1988, 84 (01): : 120 - 122
  • [30] Voltammetric behavior and determination by flow injection with amperometric detection of benzimidazoles
    de Prada, AGV
    Mena, ML
    Reviejo, AJ
    Pingarrón, JM
    ANALYTICAL LETTERS, 2004, 37 (01) : 65 - 79