An automatic determination of caffeine in soft drinks using flow injection system with amperometric detection

被引:0
|
作者
Lima, JLFC [1 ]
Delerue-Matos, C [1 ]
Nouws, HPA [1 ]
Vaz, MCVF [1 ]
机构
[1] Univ Porto, Fac Farm, Dept Quim Fis, CEQUP, P-4050 Porto, Portugal
来源
FOOD ADDITIVES AND CONTAMINANTS | 1998年 / 15卷 / 03期
关键词
caffeine; flow injection analysis; amperometric detection; soft drinks;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
An automatic procedure based on a flow injection analysis manifold has been developed for the determination of caffeine in soft drinks using amperometric detection (+1.70 V vs AgCl/Ag). The sample and standards were injected without pre-treatment, with a sampling rate of 120 determinations per hour. The determination of caffeine in several soft drinks available in Portugal using the developed automatic system provided results with mean recovery values between 98% and 103% and a mean standard deviation between 2% and 5%. The results obtained were compared with those given by the reference method recommended by AOAC. Relative deviation was always less than 4%. Reproducibility of the method was assessed by the relative standard deviation (RSD%), values of which were less than 2%.
引用
收藏
页码:265 / 269
页数:5
相关论文
共 50 条
  • [31] Determination of Acidity in Fruit Juices and Soft Drinks by Cyclic Flow Injection Analysis
    Zenki, Michio
    Katayama, Hiroaki
    Yokoyama, Takashi
    BUNSEKI KAGAKU, 2008, 57 (11) : 891 - 895
  • [32] AMPEROMETRIC DETERMINATION OF BILIRUBIN WITH FLOW-INJECTION ANALYSIS SYSTEM
    BAE, ZU
    LEE, HL
    PARK, TM
    SEO, ML
    ANALYTICAL LETTERS, 1995, 28 (10) : 1775 - 1783
  • [33] Continuous flow autoanalyzer for the sequential determination of total sugars, colorant and caffeine contents in soft drinks
    Lucena, R
    Cárdenas, S
    Gallego, M
    Valcárcel, M
    ANALYTICA CHIMICA ACTA, 2005, 530 (02) : 283 - 289
  • [34] Rapid determination of caffeine content in soft drinks using FTIR-ATR spectroscopy
    Paradkar, MM
    Irudayaraj, J
    FOOD CHEMISTRY, 2002, 78 (02) : 261 - 266
  • [35] Automated Sequential Injection Method for Determination of Caffeine in Coffee Drinks
    Mihalcikova, Lydia
    Boonjob, Warunya
    Sklenarova, Hana
    FOOD ANALYTICAL METHODS, 2018, 11 (01) : 111 - 118
  • [36] Automated Sequential Injection Method for Determination of Caffeine in Coffee Drinks
    Lýdia Mihalčíková
    Warunya Boonjob
    Hana Sklenářová
    Food Analytical Methods, 2018, 11 : 111 - 118
  • [37] Determination of free and total sulfites in wine using an automatic flow injection analysis system with voltammetric detection
    Goncalves, Luis Moreira
    Pacheco, Joao Grosso
    Magalhaes, Paulo Jorge
    Rodrigues, Jose Antonio
    Barros, Aquiles Araujo
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2010, 27 (02): : 175 - 180
  • [38] FLOW-INJECTION DETERMINATION OF NITRITE BY AMPEROMETRIC DETECTION AT A MODIFIED ELECTRODE
    COX, JA
    KULKARNI, KR
    ANALYST, 1986, 111 (10) : 1219 - 1220
  • [39] Electrochemical detection of isatin using flow injection analysis with amperometric detection
    Sanchez, Simon Wolfgang
    Jarosova, Romana
    Swain, Greg M.
    FASEB JOURNAL, 2017, 31
  • [40] Determination of arsenic in industrial samples by pervaporation flow injection with amperometric detection
    Rupasinghe, Thusitha W. T.
    Cardwell, Terence J.
    Cattrall, Robert W.
    Kolev, Spas D.
    ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 266 - 271