Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation

被引:148
|
作者
Tong, S. [1 ]
Alessio, A. M. [1 ]
Kinahan, P. E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 05期
关键词
ITERATIVE RECONSTRUCTION; FDG-PET; ALGORITHMS; RESOLUTION; SCANNER; MODEL;
D O I
10.1088/0031-9155/55/5/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The addition of accurate system modeling in PET image reconstruction results in images with distinct noise texture and characteristics. In particular, the incorporation of point spread functions (PSF) into the system model has been shown to visually reduce image noise, but the noise properties have not been thoroughly studied. This work offers a systematic evaluation of noise and signal properties in different combinations of reconstruction methods and parameters. We evaluate two fully 3D PET reconstruction algorithms: (1) OSEM with exact scanner line of response modeled (OSEM+LOR), (2) OSEM with line of response and a measured point spread function incorporated (OSEM+LOR+PSF), in combination with the effects of four post-reconstruction filtering parameters and 1-10 iterations, representing a range of clinically acceptable settings. We used a modified NEMA image quality (IQ) phantom, which was filled with Ge-68 and consisted of six hot spheres of different sizes with a target/background ratio of 4:1. The phantom was scanned 50 times in 3D mode on a clinical system to provide independent noise realizations. Data were reconstructed with OSEM+LOR and OSEM+LOR+PSF using different reconstruction parameters, and our implementations of the algorithms match the vendor's product algorithms. With access to multiple realizations, background noise characteristics were quantified with four metrics. Image roughness and the standard deviation image measured the pixel-to-pixel variation; background variability and ensemble noise quantified the region-to-region variation. Image roughness is the image noise perceived when viewing an individual image. At matched iterations, the addition of PSF leads to images with less noise defined as image roughness (reduced by 35% for unfiltered data) and as the standard deviation image, while it has no effect on background variability or ensemble noise. In terms of signal to noise performance, PSF-based reconstruction has a 7% improvement in contrast recovery at matched ensemble noise levels and 20% improvement of quantitation SNR in unfiltered data. In addition, the relations between different metrics are studied. A linear correlation is observed between background variability and ensemble noise for all different combinations of reconstruction methods and parameters, suggesting that background variability is a reasonable surrogate for ensemble noise when multiple realizations of scans are not available.
引用
收藏
页码:1453 / 1473
页数:21
相关论文
共 50 条
  • [1] Evaluation of Noise Properties in PSF-Based PET Image Reconstruction
    Tong, Shan
    Alessio, Adam M.
    Kinahan, Paul E.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3042 - 3047
  • [2] Properties of Edge Artifacts in PSF-Based PET Reconstruction
    Tong, Shan
    Alessio, Adam M.
    Thielemans, Kris
    Stearns, Charles
    Ross, Steve
    Kinahan, Paul E.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3649 - 3652
  • [3] Properties and Mitigation of Edge Artifacts in PSF-Based PET Reconstruction
    Tong, Shan
    Alessio, Adam M.
    Thielemans, Kris
    Stearns, Charles
    Ross, Steve
    Kinahan, Paul E.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2264 - 2275
  • [4] Edge artifacts in PSF-based PET image reconstruction: Characterization and mitigation
    Tong, Shan
    Alessio, Adam
    Thielemans, Kris
    Stearns, Charles
    Ross, Steve
    Kinahan, Paul
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Validation of PSF-based 3D reconstruction for myocardial blood flow measurements with Rb-82 PET
    Tolbod, L. P.
    Christensen, N. L.
    Moller, L. W.
    Aanerup, J. F. A.
    Bouchelouche, K.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S435 - S435
  • [6] Count-level Dependent Image Domain PSF Kernel Width Selection for Fully 3D PET Image Reconstruction
    Niu, Xiaofeng
    Asma, Evren
    Ye, Hongwei
    Wang, Wenli
    Gagnon, Daniel
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [7] Quantitative evaluation of edge artifacts on PET images of PSF-based reconstruction at different radioactivity concentrations
    Kidera, Daisuke
    Taniguchi, Takafumi
    Mikasa, Shohei
    Akamatsu, Go
    Komiya, Isao
    Tsutsui, Yuji
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] Quantitative evaluation of edge artifacts on PET images of PSF-based reconstruction at different radioactivity concentrations
    Kidera, Daisuke
    Taniguchi, Takafumi
    Mikasa, Shohei
    Akamatsu, Go
    Komiya, Isao
    Tsutsui, Yuji
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [9] Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system
    Rapisarda, E.
    Bettinardi, V.
    Thielemans, K.
    Gilardi, M. C.
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 197 : 190 - 193
  • [10] FULLY 3D PET IMAGE-RECONSTRUCTION WITH PLANE INTEGRALS
    WU, C
    CHEN, CT
    GUNTER, DL
    ORDONEZ, CE
    [J]. RADIOLOGY, 1992, 185 : 252 - 252