Evaluation of Noise Properties in PSF-Based PET Image Reconstruction

被引:7
|
作者
Tong, Shan [1 ]
Alessio, Adam M. [1 ]
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
D O I
10.1109/NSSMIC.2009.5401574
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The addition of accurate system modeling in PET image reconstruction results in images with distinct noise texture and characteristics. In particular, the incorporation of point spread functions (PSF) into the system model has been shown to visually reduce image noise, but the noise properties have not been thoroughly studied. This work offers a systematic evaluation of noise and signal properties in different combinations of reconstruction methods and parameters. We evaluate two fully. 3D PET reconstruction algorithms: (1) OSEM with exact scanner line of response modeled (OSEM+LOR), (2) OSEM with line of response and a measured point spread function incorporated (OSEM+LOR+PSF), in combination with the effects of 4 post filtering parameters and 1-10 iterations. We used a modified NEMA IQ phantom, which was filled with 68Ge and consisted of 6 hot spheres of different sizes with a target/background ratio of 4:1. The phantom was scanned 50 times in 3D mode on a clinical system to provide independent noise realizations. Data were reconstructed with OSEM+LOR and OSEM+LOR+PSF using different reconstruction parameters. With access to multiple realizations, 4 metrics are adopted to quantify the noise characteristics in the reconstructed images. Image roughness and the standard deviation image are measures of the pixel-to-pixel variation, while NEMA and ensemble noises quantify the region-to-region variation. In addition to 4 noise metrics, we also evaluate signal to noise performance with accepted signal strength measures (recovery coefficient, SNR for quantitation), and study the relations between different metrics. From the analysis results, a linear correlation is observed between NEMA noise and ensemble noise for all different combinations of reconstruction methods and parameters, suggesting that NEMA style noise is a reasonable surrogate for ensemble noise when multiple realizations of scans are not available in practice. At the same number of iterations, the addition of PSF reduces image roughness for unfiltered images by roughly 35%, while the addition of PSF does not reduce NEMA style or ensemble noise. When noise is measured across realizations, the PSF based method offers slightly improved (7%) signal to noise performance across a range of reconstruction parameters.
引用
收藏
页码:3042 / 3047
页数:6
相关论文
共 50 条
  • [1] Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation
    Tong, S.
    Alessio, A. M.
    Kinahan, P. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05): : 1453 - 1473
  • [2] Properties of Edge Artifacts in PSF-Based PET Reconstruction
    Tong, Shan
    Alessio, Adam M.
    Thielemans, Kris
    Stearns, Charles
    Ross, Steve
    Kinahan, Paul E.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3649 - 3652
  • [3] Properties and Mitigation of Edge Artifacts in PSF-Based PET Reconstruction
    Tong, Shan
    Alessio, Adam M.
    Thielemans, Kris
    Stearns, Charles
    Ross, Steve
    Kinahan, Paul E.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2264 - 2275
  • [4] Edge artifacts in PSF-based PET image reconstruction: Characterization and mitigation
    Tong, Shan
    Alessio, Adam
    Thielemans, Kris
    Stearns, Charles
    Ross, Steve
    Kinahan, Paul
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Quantitative evaluation of edge artifacts on PET images of PSF-based reconstruction at different radioactivity concentrations
    Kidera, Daisuke
    Taniguchi, Takafumi
    Mikasa, Shohei
    Akamatsu, Go
    Komiya, Isao
    Tsutsui, Yuji
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] Quantitative evaluation of edge artifacts on PET images of PSF-based reconstruction at different radioactivity concentrations
    Kidera, Daisuke
    Taniguchi, Takafumi
    Mikasa, Shohei
    Akamatsu, Go
    Komiya, Isao
    Tsutsui, Yuji
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [7] Fast and accurate generation method of PSF-based system matrix for PET reconstruction
    Sun, Xiao-Li
    Liu, Shuang-Quan
    Yun, Ming-Kai
    Li, Dao-Wu
    Gao, Juan
    Li, Mo-Han
    Chai, Pei
    Tang, Hao-Hui
    Zhang, Zhi-Ming
    Wei, Long
    [J]. CHINESE PHYSICS C, 2017, 41 (04)
  • [8] Fast and accurate generation method of PSF-based system matrix for PET reconstruction
    孙校丽
    刘双全
    贠明凯
    李道武
    高娟
    李默涵
    柴培
    唐浩辉
    章志明
    魏龙
    [J]. Chinese Physics C, 2017, (04) : 179 - 186
  • [9] PSF-Based Post-Back-Projection (PSF-PBF) Filtering For Low-Count PET Reconstruction
    Zhang, Bin
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [10] PET image resolution recovery using PSF-based ML-EM deconvolution with blob-based list-mode TOF reconstruction
    Zhang, Bin
    Olivier, Patrick
    Lorman, Benjamin
    Tung, Chi-hua
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52