Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold

被引:35
|
作者
Weingaertner, Sebastian [1 ,2 ,3 ]
Moeller, Steen [2 ]
Schmitter, Sebastian [2 ,4 ]
Auerbach, Edward [2 ]
Kellman, Peter [5 ]
Shenoy, Chetan [6 ]
Akcakaya, Mehmet [1 ,2 ]
机构
[1] Univ Minnesota, Elect & Comp Engn, 200 Union St SE, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[4] Phys Tech Bundesanstalt, Med Phys & Metrol Informat Technol, Berlin, Germany
[5] NHLBI, NIH, Bldg 10, Bethesda, MD 20892 USA
[6] Univ Minnesota, Dept Med, Div Cardiovasc, Box 736 UMHC, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
myocardial T-1 mapping; simultaneous multislice imaging; multiband; saturation recovery; SAPPHIRE; SPOILED GRADIENT-ECHO; INVERSION-RECOVERY; MOTION CORRECTION; TISSUE CHARACTERIZATION; T1; QUANTIFICATION; RESOLUTION; ACCURACY; HEART; MOLLI;
D O I
10.1002/mrm.26770
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a saturation recovery myocardial T-1 mapping method for the simultaneous multislice acquisition of three slices. MethodsSaturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T-1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice- and in-plane GRAPPA, CG-SENSE, and Tikhonov-regularized CG-SENSE. Accuracy, spatial variability, and interslice leakage were compared with single-band T-1 mapping in a phantom and in six healthy subjects. ResultsMultiband phantom T-1 times showed good agreement with single-band T-1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single-band imaging was lowest for GRAPPA (1.29-fold), with higher penalties for Tikhonov-regularized CG-SENSE (1.47-fold) and CG-SENSE (1.52-fold). In vivo multiband T-1 times showed no significant difference compared with single-band (T-1 timeintersegmental variability: single-band, 1580 +/- 119 ms; GRAPPA, 1572 +/- 145 ms; CG-SENSE, 1579 +/- 159 ms; Tikhonov, 1586 +/- 150 ms [analysis of variance; P=0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG-SENSE (6.2%) and Tikhonov-regularized CG-SENSE (7.9%). ConclusionMultiband accelerated myocardial T-1 mapping demonstrated the potential for single-breath-hold T-1 quantification in 16 American Heart Association segments over three slices. A 1.2- to 1.4-fold higher in vivo spatial variability was observed, where GRAPPA-based reconstruction showed the highest homogeneity and the least interslice leakage. Magn Reson Med 78:462-471, 2017. (c) 2017 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:462 / 471
页数:10
相关论文
共 50 条
  • [41] Breath-hold MR measurements of fat fraction, T1, and T2* of water and fat in vertebral bone marrow
    Le Ster, Caroline
    Gambarota, Giulio
    Lasbleiz, Jeremy
    Guillin, Raphael
    Decaux, Olivier
    Saint-Jalmes, Herve
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (03) : 549 - 555
  • [42] FASt single-breathhold 2D multislice myocardial T1 mapping (FAST1) at 1.5T for full left ventricular coverage in three breathholds
    Li Huang
    Neji, Radhouene
    Nazir, Muhummad Sohaib
    Whitaker, John
    Duong, Phuoc
    Reid, Fiona
    Bosio, Filippo
    Chiribiri, Amedeo
    Razavi, Reza
    Roujol, Sebastien
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (02) : 492 - 504
  • [43] Liver fat content and T2*: Simultaneous measurement by using breath-hold multiecho MR imaging at 3.0 T - Feasibility
    O'Regan, Declan P.
    Callaghan, Martina F.
    Wylezinska-Arridge, Marzena
    Fitzpatrick, Julie
    Naoumova, Rossi P.
    Hajnal, Joseph V.
    Schmitz, Stephan A.
    RADIOLOGY, 2008, 247 (02) : 550 - 557
  • [44] A single breath-hold multiecho T2*cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload
    Westwood, M
    Anderson, LJ
    Firmin, DN
    Gatehouse, PD
    Charrier, CC
    Wonke, B
    Pennell, DJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) : 33 - 39
  • [45] Magnetization transfer contrast of hepatic lesions in breath-hold gradient-echo images of different T1 weighting
    Schick, F
    Stern, W
    Forster, J
    Laniado, M
    Lutz, O
    Claussen, CD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 280 - 285
  • [46] Improved myocardial T1 mapping for patients with implanted cardiac devices
    Jiaxin Shao
    Shams Rashid
    Kim-Lien Nguyen
    Peng Hu
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [47] Native T1 Mapping for Myocardial Infarction Time to Throw Out the Gadolinium?
    Nezafat, Reza
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (09) : 1031 - 1033
  • [48] Myocardial Tissue Characterization with Native Myocardial T1 Mapping in SLE Patients with Chest Pain
    Shaw, Jaime
    Ishimori, Mariko L.
    Sandhu, Vaneet K.
    Sharif, Behzad
    Thomson, Louise
    Li, Debiao
    Schapira, Jay
    Wallace, Daniel
    Merz, Noel Bairey
    Weisman, Michael
    Berman, Daniel
    ARTHRITIS & RHEUMATOLOGY, 2015, 67
  • [49] Myocardial tissue characteriation with native myocardial T1 mapping in SLE patients with chest pain
    Jaime L Shaw
    Mariko L Ishimori
    Vaneet Sandhu
    Behzad Sharif
    Debiao Li
    Jay N Schapira
    Louise E Thomson
    Daniel Wallace
    C Noel Bairey Merz
    Michael Weisman
    Daniel S Berman
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [50] Improved Simultaneous Multi-slice imaging with Composition of k-space Interpolations (SMS-COOKIE) for myocardial T1 mapping
    Demirel, Omer Burak
    Weingartner, Sebastian
    Moeller, Steen
    Akcakaya, Mehmet
    PLOS ONE, 2023, 18 (07):