Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold

被引:35
|
作者
Weingaertner, Sebastian [1 ,2 ,3 ]
Moeller, Steen [2 ]
Schmitter, Sebastian [2 ,4 ]
Auerbach, Edward [2 ]
Kellman, Peter [5 ]
Shenoy, Chetan [6 ]
Akcakaya, Mehmet [1 ,2 ]
机构
[1] Univ Minnesota, Elect & Comp Engn, 200 Union St SE, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[4] Phys Tech Bundesanstalt, Med Phys & Metrol Informat Technol, Berlin, Germany
[5] NHLBI, NIH, Bldg 10, Bethesda, MD 20892 USA
[6] Univ Minnesota, Dept Med, Div Cardiovasc, Box 736 UMHC, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
myocardial T-1 mapping; simultaneous multislice imaging; multiband; saturation recovery; SAPPHIRE; SPOILED GRADIENT-ECHO; INVERSION-RECOVERY; MOTION CORRECTION; TISSUE CHARACTERIZATION; T1; QUANTIFICATION; RESOLUTION; ACCURACY; HEART; MOLLI;
D O I
10.1002/mrm.26770
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a saturation recovery myocardial T-1 mapping method for the simultaneous multislice acquisition of three slices. MethodsSaturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T-1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice- and in-plane GRAPPA, CG-SENSE, and Tikhonov-regularized CG-SENSE. Accuracy, spatial variability, and interslice leakage were compared with single-band T-1 mapping in a phantom and in six healthy subjects. ResultsMultiband phantom T-1 times showed good agreement with single-band T-1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single-band imaging was lowest for GRAPPA (1.29-fold), with higher penalties for Tikhonov-regularized CG-SENSE (1.47-fold) and CG-SENSE (1.52-fold). In vivo multiband T-1 times showed no significant difference compared with single-band (T-1 timeintersegmental variability: single-band, 1580 +/- 119 ms; GRAPPA, 1572 +/- 145 ms; CG-SENSE, 1579 +/- 159 ms; Tikhonov, 1586 +/- 150 ms [analysis of variance; P=0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG-SENSE (6.2%) and Tikhonov-regularized CG-SENSE (7.9%). ConclusionMultiband accelerated myocardial T-1 mapping demonstrated the potential for single-breath-hold T-1 quantification in 16 American Heart Association segments over three slices. A 1.2- to 1.4-fold higher in vivo spatial variability was observed, where GRAPPA-based reconstruction showed the highest homogeneity and the least interslice leakage. Magn Reson Med 78:462-471, 2017. (c) 2017 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:462 / 471
页数:10
相关论文
共 50 条
  • [31] COMPARISON OF BREATH-HOLD T1-WEIGHTED MR SEQUENCES FOR IMAGING OF THE LIVER
    SEMELKA, RC
    WILLMS, AB
    BROWN, MA
    BROWN, ED
    FINN, JP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (06): : 759 - 765
  • [32] Quantitative single breath-hold renal arterial spin labeling imaging at 7T
    Li, Xiufeng
    Auerbach, Edward J.
    Van de Moortele, Pierre-Francois
    Ugurbil, Kamil
    Metzger, Gregory J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 815 - 825
  • [33] Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching
    Lyu, Zhenfeng
    Hua, Sha
    Xu, Jian
    Shen, Yiwen
    Guo, Rui
    Hu, Peng
    Qi, Haikun
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [34] Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching
    Zhenfeng Lyu
    Sha Hua
    Jian Xu
    Yiwen Shen
    Rui Guo
    Peng Hu
    Haikun Qi
    Journal of Cardiovascular Magnetic Resonance, 25
  • [35] Native T1 Mapping by 3-T CMR Imaging for Characterization of Chronic Myocardial Infarctions
    Kali, Avinash
    Choi, Eui-Young
    Sharif, Behzad
    Kim, Young Jin
    Bi, Xiaoming
    Spottiswoode, Bruce
    Cokic, Ivan
    Yang, Hsin-Jung
    Tighiouart, Mourad
    Conte, Antonio Hernandez
    Li, Debiao
    Berman, Daniel S.
    Choi, Byoung Wook
    Chang, Hyuk-Jae
    Dharmakumar, Rohan
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (09) : 1019 - 1030
  • [36] LIVER-BUDA-SAGE: SIMULTANEOUS WHOLE LIVER T2 AND T*2 MAPPING IN ONE BREATH-HOLD
    Zhang, Zijing
    Ye, Huihui
    Li, Maosen
    Liu, Huafeng
    Bilgic, Berkin
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [37] Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution
    Qi, Haikun
    Bustin, Aurelien
    Cruz, Gastao
    Jaubert, Olivier
    Chen, Huijun
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 159 - 169
  • [38] Editorial for "Dynamic Glucose-Enhanced Imaging of the Liver Using Breath-Hold Black Blood Quantitative T1ρ MRI at 3.0T"
    Hussain, Shahid M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 1110 - 1111
  • [39] Fat-saturated dark-blood cardiac T2 mapping in a single breath-hold
    Hu, Chenxi
    Huber, Steffen
    Nguyen, Vinh
    Baldassarre, Lauren
    Mojibian, Hamid
    Peters, Dana
    MAGNETIC RESONANCE IMAGING, 2021, 81 : 24 - 32
  • [40] Can Chronic Myocardial Infarction Be Detected by Native T1 Mapping?
    Kellman, Peter
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (12) : 2080 - 2081