An estimate of 90Y dosimetry for bremsstrahlung SPECT/CT imaging in liver therapy with 90Y microspheres

被引:1
|
作者
Knesaurek, Karin [1 ]
机构
[1] Icahn Sch Med Mt Sinai, Div Nucl Med, Dept Radiol, Box 1141,One Gustave L Levy Pl, New York, NY 10029 USA
关键词
Bremsstrahlung SPECT/CT; Y-90; dosimetry; Microspheres; Hepatocellular carcinoma; HEPATOCELLULAR-CARCINOMA; RADIOEMBOLIZATION; IMPACT;
D O I
10.1016/j.ejrad.2021.109698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Bremsstrahlung SPECT/CT (bSPECT/CT) is one of the most common methods for post-therapy imaging in Y-90 microspheres selective internal radiation therapy (SIRT) of liver cancers. Here, we are proposing a simple approach using bSPECT/CT to estimate mean absorbed dose to the liver in patients undergoing treatment with Y-90 microspheres. Materials and methods: In our previous study comparing Y-90 dosimetry obtained using bSPECT/CT vs PET/CT, we found that there was a large difference between the mean absorbed dose values to the whole-liver. However, there was a high linear correlation between the doses, which presented an opportunity for quantitative assessment using bSPECT/CT Y-90 imaging. In this study, after treatment with Y-90 microspheres, 43 patients were immediately imaged on a dual-head Infinia SPECT/CT gamma camera and on a mCT PET/CT system. Images from 25 of the patients, randomly selected, were used to calculate the correlation of mean liver doses obtained from bSPECT/CT vs. PET/CT. For the remaining 18 patients, the calculated correlation was used to estimate doses obtained from bSPECT/CT, and these estimations were then compared to the doses obtained from PET/CT, considered the gold standard for quantitative analysis. Results: From the 25 selected patients, the calculated linear correlation between bSPECT/CT and PET/CT Y-90 mean absorbed doses in whole liver was high ((r) over cap (2) = 0.97), with a slope of 2.80 and an intercept of -0.63. This linear fit was used to calculate the bSPECT/CT doses for the remaining 18 patients. For these patients, the mean whole-liver dose obtained from bSPECT/CT fitted data vs that obtained from PET/CT were 50.59 Gy and 50.81 Gy, respectively. The average dose difference was 0.2 +/- 5.4 Gy (range - 18.2%-13.0%). The repeatability coefficient was 10.5 (20.8 % of the mean). Conclusion: Although quantitative bremsstrahlung imaging is difficult, it is possible to calculate adequate estimates of whole-liver dosimetry from bSPECT/CT imaging that is calibrated using its correlation with posttherapy PET/CT Y-90 images.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Effect of Monte Carlo Collimator Modelling on 90Y Bremsstrahlung SPECT Images
    Porter, C. A.
    Walker, M. D.
    Bradley, K. M.
    McGowan, D. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S502 - S502
  • [42] Developing a protocol for 90Y bremsstrahlung imaging after Transarterial Radioembolization
    Talebi, A. S.
    Rajabi, H.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (03)
  • [43] BREMSSTRAHLUNG FROM 90SR- 90Y IN THIN ABSORBERS
    BUSTARD, TS
    SILVERMAN, J
    NUCLEAR SCIENCE AND ENGINEERING, 1967, 27 (03) : 586 - +
  • [44] SPECT/CT 90Y-Bremsstrahlung images for dosimetry during therapy
    Fabbri, C.
    Sarti, G.
    Agostini, M.
    Di Dia, A.
    Paganelli, G.
    ECANCERMEDICALSCIENCE, 2008, 2
  • [45] EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres
    Carlo Chiesa
    Katarina Sjogreen-Gleisner
    Stephan Walrand
    Lidia Strigari
    Glenn Flux
    Jonathan Gear
    Caroline Stokke
    Pablo Minguez Gabina
    Peter Bernhardt
    Mark Konijnenberg
    EJNMMI Physics, 8
  • [46] 90Y Radioembolization as Salvage Therapy
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 19N - 19N
  • [47] EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres
    Chiesa, Carlo
    Sjogreen-Gleisner, Katarina
    Walrand, Stephan
    Strigari, Lidia
    Flux, Glenn
    Gear, Jonathan
    Stokke, Caroline
    Gabina, Pablo Minguez
    Bernhardt, Peter
    Konijnenberg, Mark
    EJNMMI PHYSICS, 2021, 8 (01)
  • [48] The Essential Role of Monte Carlo Simulations for Lung Dosimetry in Liver Radioembolization with 90Y Microspheres
    d'Andrea, Edoardo
    Lanconelli, Nico
    Cremonesi, Marta
    Patera, Vincenzo
    Pacilio, Massimiliano
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [49] Dosimetry of yttrium-labelled radiopharmaceuticals for internal therapy: 86Y or 90Y imaging?
    Walrand, Stephan
    Flux, Glenn D.
    Konijnenberg, Mark W.
    Valkema, Roelf
    Krenning, Eric P.
    Lhommel, Renaud
    Pauwels, Stanislas
    Jamar, Francois
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : 57 - 68
  • [50] Dosimetry of yttrium-labelled radiopharmaceuticals for internal therapy: 86Y or 90Y imaging?
    Stephan Walrand
    Glenn D. Flux
    Mark W. Konijnenberg
    Roelf Valkema
    Eric P. Krenning
    Renaud Lhommel
    Stanislas Pauwels
    Francois Jamar
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 57 - 68