An estimate of 90Y dosimetry for bremsstrahlung SPECT/CT imaging in liver therapy with 90Y microspheres

被引:1
|
作者
Knesaurek, Karin [1 ]
机构
[1] Icahn Sch Med Mt Sinai, Div Nucl Med, Dept Radiol, Box 1141,One Gustave L Levy Pl, New York, NY 10029 USA
关键词
Bremsstrahlung SPECT/CT; Y-90; dosimetry; Microspheres; Hepatocellular carcinoma; HEPATOCELLULAR-CARCINOMA; RADIOEMBOLIZATION; IMPACT;
D O I
10.1016/j.ejrad.2021.109698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Bremsstrahlung SPECT/CT (bSPECT/CT) is one of the most common methods for post-therapy imaging in Y-90 microspheres selective internal radiation therapy (SIRT) of liver cancers. Here, we are proposing a simple approach using bSPECT/CT to estimate mean absorbed dose to the liver in patients undergoing treatment with Y-90 microspheres. Materials and methods: In our previous study comparing Y-90 dosimetry obtained using bSPECT/CT vs PET/CT, we found that there was a large difference between the mean absorbed dose values to the whole-liver. However, there was a high linear correlation between the doses, which presented an opportunity for quantitative assessment using bSPECT/CT Y-90 imaging. In this study, after treatment with Y-90 microspheres, 43 patients were immediately imaged on a dual-head Infinia SPECT/CT gamma camera and on a mCT PET/CT system. Images from 25 of the patients, randomly selected, were used to calculate the correlation of mean liver doses obtained from bSPECT/CT vs. PET/CT. For the remaining 18 patients, the calculated correlation was used to estimate doses obtained from bSPECT/CT, and these estimations were then compared to the doses obtained from PET/CT, considered the gold standard for quantitative analysis. Results: From the 25 selected patients, the calculated linear correlation between bSPECT/CT and PET/CT Y-90 mean absorbed doses in whole liver was high ((r) over cap (2) = 0.97), with a slope of 2.80 and an intercept of -0.63. This linear fit was used to calculate the bSPECT/CT doses for the remaining 18 patients. For these patients, the mean whole-liver dose obtained from bSPECT/CT fitted data vs that obtained from PET/CT were 50.59 Gy and 50.81 Gy, respectively. The average dose difference was 0.2 +/- 5.4 Gy (range - 18.2%-13.0%). The repeatability coefficient was 10.5 (20.8 % of the mean). Conclusion: Although quantitative bremsstrahlung imaging is difficult, it is possible to calculate adequate estimates of whole-liver dosimetry from bSPECT/CT imaging that is calibrated using its correlation with posttherapy PET/CT Y-90 images.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] 90Y microspheres show promise in liver cancer
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (12) : 32N - +
  • [22] Evaluation of 99mTc-MAA SPECT/CT-based dosimetry with 90Y PET/MR-based dosimetry in 90Y microsphere treatment
    Namazova, A.
    Yeyin, N.
    Besli, L. Uslu
    Sonmezoglu, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S635 - S636
  • [23] Extrahepatic 90Y Complication; Gastric Ulcer Secondary to 90Y Therapy for Liver Metastasis Despite Negative Preprocedural Imaging
    Shea, Connor
    Lamberg, Hannah
    Turk, Sevcan
    Sanogo, Mamadou
    Turgeon, Danielle
    Nojkov, Broko
    Frey, Kirk
    Raffel, David
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 58 (02) : 86 - 91
  • [24] Extrahepatic 90Y Complication; Gastric Ulcer Secondary to 90Y Therapy for Liver Metastasis Despite Negative Preprocedural Imaging
    Connor Shea
    Hannah Lamberg
    Sevcan Turk
    Mamadou Sanogo
    Danielle Turgeon
    Broko Nojkov
    Kirk Frey
    David Raffel
    Nuclear Medicine and Molecular Imaging, 2024, 58 : 86 - 91
  • [25] Development and evaluation of an improved quantitative 90Y bremsstrahlung SPECT method
    Rong, Xing
    Du, Yong
    Ljungberg, Michael
    Rault, Erwann
    Vandenberghe, Stefaan
    Frey, Eric C.
    MEDICAL PHYSICS, 2012, 39 (05) : 2346 - 2358
  • [26] Evaluation of quantitative 90Y bremsstrahlung SPECT based on patient studies
    Minarik, David
    Gleisner, Katarina Sjogreen
    Ljungberg, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [27] Comparison of PET/CT and PET/MR imaging and dosimetry of yttrium-90 (90Y) in patients with unresectable hepatic tumors who have received intra-arterial radioembolization therapy with 90Y microspheres
    Knesaurek, Karin
    Tuli, Abbas
    Kim, Edward
    Heiba, Sherif
    Kostakoglu, Lale
    EJNMMI PHYSICS, 2018, 5
  • [28] Comparison of PET/CT and PET/MR imaging and dosimetry of yttrium-90 (90Y) in patients with unresectable hepatic tumors who have received intra-arterial radioembolization therapy with 90Y microspheres
    Karin Knešaurek
    Abbas Tuli
    Edward Kim
    Sherif Heiba
    Lale Kostakoglu
    EJNMMI Physics, 5
  • [29] Quantitative analysis of 90Y Bremsstrahlung SPECT/CT images for application to 3D patient specific dosimetry
    Fabbri, C.
    Sarti, G.
    Cremonesi, M.
    Ferrari, M.
    Agostini, M.
    Pedroli, G.
    Paganelli, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S353 - S353
  • [30] PET/CT imaging of 90Y radiation synovectomy
    Barber, Thomas W.
    Yap, Kenneth S. K.
    Kalff, Victor