EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres

被引:72
|
作者
Chiesa, Carlo [1 ]
Sjogreen-Gleisner, Katarina [2 ]
Walrand, Stephan [3 ]
Strigari, Lidia [4 ]
Flux, Glenn [5 ,6 ]
Gear, Jonathan [5 ,6 ]
Stokke, Caroline [7 ]
Gabina, Pablo Minguez [8 ]
Bernhardt, Peter [9 ,10 ]
Konijnenberg, Mark [11 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Nucl Med Unit, Milan, Italy
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Catholic Univ Louvain, Nucl Med Mol Imaging Radiotherapy & Oncol Unit MI, IECR, Brussels, Belgium
[4] IRCCS Azienda Osped Univ Bologna, Med Phys Div, Bologna, Italy
[5] Royal Marsden Hosp, Joint Dept Phys, Sutton, Surrey, England
[6] Inst Canc Res, Sutton, Surrey, England
[7] Oslo Univ Hosp, Dept Diagnost Phys, Oslo, Norway
[8] Gurutzeta Cruces Univ Hosp, Dept Med Phys & Radiat Protect, Baracaldo, Spain
[9] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[10] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[11] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
关键词
Radioembolization dosimetry; Tc-99m-MAA; Y-90; microspheres; Lung shunt; Liver dosimetry; Tumour dosimetry; PET; Prospective; retrospective dosimetry; SELECTIVE INTERNAL RADIOTHERAPY; VOXEL S-VALUES; HEPATOCELLULAR-CARCINOMA; GLASS MICROSPHERES; RADIATION-THERAPY; PARTITION MODEL; TC-99M-MACROAGGREGATED ALBUMIN; BREMSSTRAHLUNG SPECT/CT; IMAGE-RECONSTRUCTION; QUANTITATIVE SPECT;
D O I
10.1186/s40658-021-00394-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in Y-90 microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of Tc-99m albumin macro-aggregates (MAA) and Y-90 microsphere biodistribution is also assumed. The large observed discrepancies in some patients between Tc-99m-MAA predictions and actual Y-90 microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected Tc-99m-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and Y-90 TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected Tc-99m-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative Y-90 bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
引用
收藏
页数:44
相关论文
共 50 条
  • [1] EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres
    Carlo Chiesa
    Katarina Sjogreen-Gleisner
    Stephan Walrand
    Lidia Strigari
    Glenn Flux
    Jonathan Gear
    Caroline Stokke
    Pablo Minguez Gabina
    Peter Bernhardt
    Mark Konijnenberg
    [J]. EJNMMI Physics, 8
  • [2] Factors modulating 99mTc-MAA planar lung dosimetry for 90Y radioembolization
    Lopez, Benjamin P.
    Mahvash, Armeen
    Long, James P.
    Lam, Marnix G. E. H.
    Kappadath, S. Cheenu
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [3] Discrepancy between 99mTc-MAA SPECT and 90Y glass microspheres PET lung dosimetry in radioembolization of hepatocarcinoma
    Chiesa, C.
    Mira, M.
    De Nile, M.
    Maccauro, M.
    Spreafico, C.
    Zanette, C.
    Aliberti, G.
    Cascella, T.
    Romito, R.
    Sposito, C.
    Seregni, E.
    Marchiano', A.
    Crippa, F.
    Mazzaferro, V.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S406 - S406
  • [4] Evaluation of 99mTc-MAA SPECT/CT-based dosimetry with 90Y PET/MR-based dosimetry in 90Y microsphere treatment
    Namazova, A.
    Yeyin, N.
    Besli, L. Uslu
    Sonmezoglu, K.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S635 - S636
  • [5] Planning Dosimetry for 90Y Therapy: Evaluating the Predictive Power of 99mTc-MAA and the Partition Model
    Thomas, M. Allan
    Mahvash, Armeen
    Abdelsalam, Mohamed
    Kaseb, Ahmed
    Kappadath, S. Cheenu
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E351 - E351
  • [6] SPECT/CT with 99mTc-MAA in Radioembolization with 90Y Microspheres in Patients with Hepatocellular Cancer
    Hamami, Monia E.
    Poeppel, Thorsten D.
    Mueller, Stephan
    Heusner, Till
    Bockisch, Andreas
    Hilgard, Philipp
    Antoch, Gerald
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (05) : 688 - 692
  • [7] Comparison of 99mTc-MAA SPECT/CT predictive dosimetry and 90Y PET/CT posttreatment dosimetry in Radioembolization of Hepatic Tumours
    Ferrando, O.
    Foppiano, F.
    Ciarmiello, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S281 - S281
  • [8] Radioembolization of hepatocarcinoma with 90Y glass microspheres: clinical implications of low precision of 99mTc-MAA SPECT/CT dosimetry on lungs and lesions
    Chiesa, C.
    Mazzaglia, S.
    Maccauro, M.
    De Nile, M. C.
    Romano, C.
    Mira, M.
    Marchiano', A.
    Seregni, E.
    Mazzaferro, V.
    Spreafico, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S241 - S241
  • [9] Quantitative comparison of 90Y microspheres and 99mTc-MAA images in the treatment of liver cancer
    Knesaurek, K.
    Machac, J.
    Muzinic, M.
    DaCosta, M.
    Zhang, Z.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S281 - S282
  • [10] An estimate of 90Y dosimetry for bremsstrahlung SPECT/CT imaging in liver therapy with 90Y microspheres
    Knesaurek, Karin
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139