EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres

被引:83
|
作者
Chiesa, Carlo [1 ]
Sjogreen-Gleisner, Katarina [2 ]
Walrand, Stephan [3 ]
Strigari, Lidia [4 ]
Flux, Glenn [5 ,6 ]
Gear, Jonathan [5 ,6 ]
Stokke, Caroline [7 ]
Gabina, Pablo Minguez [8 ]
Bernhardt, Peter [9 ,10 ]
Konijnenberg, Mark [11 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Nucl Med Unit, Milan, Italy
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Catholic Univ Louvain, Nucl Med Mol Imaging Radiotherapy & Oncol Unit MI, IECR, Brussels, Belgium
[4] IRCCS Azienda Osped Univ Bologna, Med Phys Div, Bologna, Italy
[5] Royal Marsden Hosp, Joint Dept Phys, Sutton, Surrey, England
[6] Inst Canc Res, Sutton, Surrey, England
[7] Oslo Univ Hosp, Dept Diagnost Phys, Oslo, Norway
[8] Gurutzeta Cruces Univ Hosp, Dept Med Phys & Radiat Protect, Baracaldo, Spain
[9] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[10] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[11] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
关键词
Radioembolization dosimetry; Tc-99m-MAA; Y-90; microspheres; Lung shunt; Liver dosimetry; Tumour dosimetry; PET; Prospective; retrospective dosimetry; SELECTIVE INTERNAL RADIOTHERAPY; VOXEL S-VALUES; HEPATOCELLULAR-CARCINOMA; GLASS MICROSPHERES; RADIATION-THERAPY; PARTITION MODEL; TC-99M-MACROAGGREGATED ALBUMIN; BREMSSTRAHLUNG SPECT/CT; IMAGE-RECONSTRUCTION; QUANTITATIVE SPECT;
D O I
10.1186/s40658-021-00394-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in Y-90 microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of Tc-99m albumin macro-aggregates (MAA) and Y-90 microsphere biodistribution is also assumed. The large observed discrepancies in some patients between Tc-99m-MAA predictions and actual Y-90 microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected Tc-99m-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and Y-90 TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected Tc-99m-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative Y-90 bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
引用
收藏
页数:44
相关论文
共 50 条
  • [31] Addressing lung truncation in 99mTc-MAA SPECT/CT for 90Y microsphere radioembolization treatment planning
    Thomas, M. Allan
    Laforest, Richard
    Karageorgiou, John
    Giardina, Dan
    Fraum, Tyler J.
    Malone, Chris D.
    Mikell, Justin K.
    EJNMMI PHYSICS, 2024, 11 (01):
  • [32] The Essential Role of Monte Carlo Simulations for Lung Dosimetry in Liver Radioembolization with 90Y Microspheres
    d'Andrea, Edoardo
    Lanconelli, Nico
    Cremonesi, Marta
    Patera, Vincenzo
    Pacilio, Massimiliano
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [33] Quantification of 99mTc-MAA for lung shunt estimation before 90Y radioembolization: comparison of three methods
    Milan, E.
    Barbisan, D.
    Zambon, G.
    La Verde, C.
    Barzi, P.
    Sutto, M.
    Barbiero, S.
    Nistri, F.
    Vendramin, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S663 - S663
  • [34] Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres
    Etienne Garin
    Yan Rolland
    Sophie Laffont
    Julien Edeline
    European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 559 - 575
  • [35] Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres
    Garin, Etienne
    Rolland, Yan
    Laffont, Sophie
    Edeline, Julien
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (03) : 559 - 575
  • [36] Dose volume histogram comparison between pretreatment 99mTc-MAA SPECT/CT and post treatment 90Y PET/CT voxel-based dosimetry with rigid and deformable contour registration algorithms in radioembolization with resin 90Y microspheres
    Della Gala, G.
    Santoro, M.
    Paolani, G.
    Strolin, S.
    Rizzini, E. Lodi
    Cappelli, A.
    Mosconi, C.
    Calderoni, L.
    Morganti, A.
    Fanti, S.
    Golfieri, R.
    Strigari, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S112 - S112
  • [37] The value of 99mTc-MAA SPECT/CT for lung shunt estimation in 90Y radioembolization: a phantom and patient study
    Jonathan D. Allred
    Jeremy Niedbala
    Justin K. Mikell
    Dawn Owen
    Kirk A. Frey
    Yuni K. Dewaraja
    EJNMMI Research, 8
  • [38] Combining 99mTc-MAA SPECT/CT and 18-FDG PET/CT for planning liver 90Y radioembolization (SIRT)
    Chalaye, J.
    Bernardini, M.
    Smadja, C.
    Pellerin, O.
    Dubreuil, O.
    Pelage, J.
    Sapoval, M.
    Rougier, P.
    Taieb, J.
    Darcourt, J.
    Faraggi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S435 - S435
  • [39] 99MTC-MAA HEPATIC PERFUSION IMAGING PRIOR TO 90Y RADIOEMBOLIZATION: HOW THORACIC UPTAKE CHANGES MANAGEMENT
    Capaccione, Kathleen
    Salvatore, Mary
    CHEST, 2020, 158 (04) : 1400A - 1400A
  • [40] The value of 99mTc-MAA SPECT/CT for lung shunt estimation in 90Y radioembolization: a phantom and patient study
    Allred, Jonathan D.
    Niedbala, Jeremy
    Mikell, Justin K.
    Owen, Dawn
    Frey, Kirk A.
    Dewaraja, Yuni K.
    EJNMMI RESEARCH, 2018, 8