Rotational Fluoroscopy Assists in Detection of Intra-Articular Screw Penetration During Volar Plating of the Distal Radius

被引:14
|
作者
Tweet, Matthew L. [1 ]
Calfee, Ryan P. [1 ]
Stern, Peter J. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Orthopaed Surg, Cincinnati, OH USA
来源
基金
美国国家卫生研究院;
关键词
Complication; distal radius; fracture; fluoroscopy; volar plate; INTERNAL-FIXATION; OPEN REDUCTION; FRACTURES;
D O I
10.1016/j.jhsa.2009.12.033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Intra-articular screw penetration is one complication of volar plate fixation of distal radius fractures. This study was designed to determine the most commonly used imaging techniques and views during volar plating of distal radius fractures and to evaluate surgeons' ability to detect intra-articular screw placement on static fluoroscopic images and rotational fluoroscopy. Methods Active members of the American Society for Surgery of the Hand were polled regarding preferred imaging techniques (fluoroscopic vs cassette radiographs) and views (rotational fluoroscopy or static orthogonal/anatomic tilt/semipronated imaging) during volar plating of distal radius fractures. After the survey, volar locking plates were applied to 30 cadaveric distal radiuses. We intentionally penetrated a single screw into the radiocarpal joint in half of the specimens (15 arms) and intentionally did not penetrate the radiocarpal joint in the other half. Imaging (standard posteroanterior [PA] and lateral views, 11 degrees tilt PA and 22 tilt lateral views, and two 360 degrees fluoroscopy movies) was performed using a custom jig. Five surgeons blinded to results reviewed randomized image sets evaluating for intra-articular screw placement. Receiver operating characteristic curves were constructed to compare the reliability of each fluoroscopic projection or movie. Results Among 696 survey respondents, 606 exclusively used fluoroscopic imaging (without cassette radiographs) and over 450 preferred either tilt images or rotational fluoroscopy to detect intra-articular screw penetration. In our cadaveric model, rotational fluoroscopy provided the highest sensitivity (93%) and specificity (96%) for the detection of intra-articular screw penetration. Rotational fluoroscopy was significantly more reliable (p<.01) than most images (standard lateral, 11 degrees PA, 22 degrees lateral, paired PA/lateral) and trended strongly toward better reliability for all remaining images (standard PA [p=.07], paired 11 degrees PA/22 degrees lateral [p=.08], and 22 degrees tilt fluoroscopy movie [p=.11]). Conclusions Rotational fluoroscopy improves the surgeon's ability to detect intra-articular screw penetration during volar plating of the distal radius. No combination of imaging allowed detection of all intra-articular screws. A high level of suspicion for intra-articular screw penetration should be maintained during volar plating of distal radial fractures. (J Hand Surg 2010;35A:619-627. Copyright (C) 2010 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:619 / 627
页数:9
相关论文
共 50 条
  • [31] Volar plating for intra-articular fracture of the base of the proximal phalanx
    Hattori, Yasunori
    Doi, Kazuteru
    Sakamoto, Soutetsu
    Yamasaki, Hiroshi
    Wahegaonkar, Abhijeet
    Addosooki, Ahmad
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (08): : 1299 - 1303
  • [32] Comparison of ultrasound and dorsal tangential view for dorsal cortex screw penetration in volar plating of the distal radius
    Yang, Jui-Ming
    Wang, Chien-Kuo
    Lin, Wei-Chin
    Li, Chung-Yi
    Su, Fong-Chin
    Jou, I-Ming
    Wu, Po-Ting
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (01) : 235 - 240
  • [33] Treatment of Intra-articular Distal Radius Fractures
    Omokawa, Shohei
    Abe, Yukio
    Imatani, Junya
    Moritomo, Hisao
    Suzuki, Daisuke
    Onishi, Tadanobu
    HAND CLINICS, 2017, 33 (03) : 529 - +
  • [34] The Safety of the Volar Intraarticular Extended Window (VIEW) Approach for Intra-articular Distal Radius Fractures
    Kamal, Robin N.
    Gomez, Giselle I.
    Schultz, Emily A.
    Shapiro, Lauren M.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023,
  • [35] Comparison of 4 Fluoroscopic Views for Dorsal Cortex Screw Penetration After Volar Plating of the Distal Radius
    Ozer, Kagan
    Wolf, Jennifer M.
    Watkins, Bruce
    Hak, David J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (05): : 963 - 967
  • [36] Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture
    Haug, Luzian C. P.
    Deml, Christian
    Blauth, Michael
    Arora, Rohit
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1279 - 1282
  • [37] Managing the Intra-articular Distal Radius Malunion
    Boe, Chelsea C.
    Kennedy, Stephen A.
    HAND CLINICS, 2024, 40 (01) : 79 - 87
  • [38] Intra-articular fractures of the distal aspect of the radius
    Trumble, TE
    Culp, R
    Hanel, DP
    Geissler, WB
    Berger, RA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04): : 582 - 600
  • [39] Treating intra-articular distal radius fractures
    Smith, Derek
    BRITISH COLUMBIA MEDICAL JOURNAL, 2018, 60 (01): : 17 - 17
  • [40] A Prospective Randomized Comparison of Variable-Angle and Fixed-Angle Volar Locking Plating for Intra-Articular Distal Radius Fractures
    Nishiwaki, Masao
    Terasaka, Yukinori
    Kiyota, Yasuhiro
    Inaba, Naoto
    Koyanagi, Takahiro
    Horiuchi, Yukio
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2021, 46 (07): : 584 - 593