Comparison of ultrasound and dorsal tangential view for dorsal cortex screw penetration in volar plating of the distal radius

被引:2
|
作者
Yang, Jui-Ming [1 ,2 ]
Wang, Chien-Kuo [3 ]
Lin, Wei-Chin [4 ,5 ]
Li, Chung-Yi [6 ,7 ,8 ]
Su, Fong-Chin [1 ,9 ]
Jou, I-Ming [10 ,11 ]
Wu, Po-Ting [1 ,5 ,9 ,12 ,13 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
[2] Tainan ShinLau Christian Hosp, Dept Orthoped, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Dept Radiol, Coll Med, Tainan, Taiwan
[4] Show Chwan Mem Hosp, Dept Orthopaed Surg, Changhua, Taiwan
[5] Natl Cheng Kung Univ Hosp, Natl Cheng Kung Univ, Dept Orthoped, Coll Med, Tainan, Taiwan
[6] Natl Cheng Kung Univ, Dept Publ Hlth, Coll Med, Tainan, Taiwan
[7] China Med Univ, Dept Publ Hlth, Coll Publ Hlth, Taichung, Taiwan
[8] Asia Univ, Dept Healthcare Adm, Coll Med & Hlth Sci, Taichung, Taiwan
[9] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan, Taiwan
[10] E Da Hosp, Dept Orthoped, Kaohsiung, Taiwan
[11] Shou Univ, Coll Med, Sch Med, Kaohsiung, Taiwan
[12] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, 1 Univ Rd, Tainan 701, Taiwan
[13] Natl Cheng Kung Univ, Coll Med, Dept Biochem & Mol Biol, Tainan, Taiwan
关键词
fluoroscopy; radius fractures; screws penetration; ultrasound; volar plating; PROMINENT HARDWARE; SURGICAL-TREATMENT; FRACTURES; PALMAR; COMPLICATIONS; PLATES;
D O I
10.1002/jor.25341
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the accuracy of the fluoroscopic dorsal tangential view (DTV) and an ultrasound (US) examination in detecting dorsal screw penetration during volar distal radius plating. In six fresh cadaveric distal radii, seven periarticular locking screws in two rows for each plate were inserted according to the measured length using a depth gauge and then replaced with another that was 1 and 2 mm longer, respectively. The actual protruded length of each screw was determined using computed tomography (CT) images. The accuracy of US and DTV measurements was determined using the intraclass correlation coefficient (ICC), as both measurements were compared with CT measurements. The ICC of US and DTV was 0.96 and 0.75, respectively, for all screws. After excluding the data for proximal-row screws, the ICC of US remained unchanged at 0.96, and that of DTV improved to 0.86. The ICC of US was significantly higher than that of DTV (p < 0.01). US had a 100% detection rate for screw protrusion of more than 1.0 mm. US examination showed excellent consistency with CT measurements and its accuracy was not affected by screw location. US might thus be a practical tool for detecting dorsal cortex screw penetration during volar distal radius plating.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [1] The Dorsal Tangential X-Ray View to Determine Dorsal Screw Penetration During Volar Plating of Distal Radius Fractures
    Brunner, Alexander
    Siebert, Christin
    Stieger, Claudia
    Kastius, Alexander
    Link, Bjoern-Christian
    Babst, Reto
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01): : 27 - 33
  • [2] Comparison of 4 Fluoroscopic Views for Dorsal Cortex Screw Penetration After Volar Plating of the Distal Radius
    Ozer, Kagan
    Wolf, Jennifer M.
    Watkins, Bruce
    Hak, David J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (05): : 963 - 967
  • [3] Volar plating in distal radius fractures: A prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration
    Bergsma, Minke
    Doornberg, Job N.
    Duit, Robin
    Saarig, Aimane
    Worsley, David
    Jaarsma, Ruurd
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (10): : 1810 - 1815
  • [4] A Prospective Cohort Study on Accuracy of Dorsal Tangential Views to Avoid Screw Penetration With Volar Plating of Distal Radius Fractures
    Bergsma, Minke
    Bulstra, Anne Eva
    Morris, David
    Janssen, Michiel
    Jaarsma, Ruurd
    Doornberg, Job
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (09) : E291 - E297
  • [5] The intraoperative dorsal tangential view and the radial groove view of the distal radius to detect dorsal screw protrusion in volar plating: teaching effect and value in clinical practise
    Fassler, David
    Pozzi, Lara
    Doert, Aleksis
    Schlappi, Michel
    Meier, Christoph
    SWISS MEDICAL WEEKLY, 2023, 153 : 56S - 56S
  • [6] The Intraoperative Dorsal Tangential View and the Radial Groove View of the Distal Radius to Detect Dorsal Screw Protrusion in Volar Plating: Teaching Effect and Value in Clinical Practise
    Fassler, D.
    Pozzi, L.
    Doert, A.
    Schlappi, M.
    Meier, C.
    BRITISH JOURNAL OF SURGERY, 2023, 110 (SUPP 5)
  • [7] Detection of dorsal screw penetration during volar plating of the distal radius fractures: A comparison of different fluoroscopic views and screw sizes
    Zhuang, Yun-Qiang
    Zhang, Jia-Yu
    Yu, Xian-Bin
    Chen, Hua
    Wu, Yao-Sen
    Sun, Liao-Jun
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (02) : 377 - 380
  • [8] Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture
    Haug, Luzian C. P.
    Deml, Christian
    Blauth, Michael
    Arora, Rohit
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1279 - 1282
  • [9] Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture
    Luzian C. P. Haug
    Christian Deml
    Michael Blauth
    Rohit Arora
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1279 - 1282
  • [10] Dorsal Screw Penetration With the Use of Volar Plating of Distal Radius Fractures: How Can You Best Detect?
    Hill, Brian W.
    Shakir, Irshad
    Cannada, Lisa K.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (10) : e408 - e413