Comparison of ultrasound and dorsal tangential view for dorsal cortex screw penetration in volar plating of the distal radius

被引:2
|
作者
Yang, Jui-Ming [1 ,2 ]
Wang, Chien-Kuo [3 ]
Lin, Wei-Chin [4 ,5 ]
Li, Chung-Yi [6 ,7 ,8 ]
Su, Fong-Chin [1 ,9 ]
Jou, I-Ming [10 ,11 ]
Wu, Po-Ting [1 ,5 ,9 ,12 ,13 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
[2] Tainan ShinLau Christian Hosp, Dept Orthoped, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Dept Radiol, Coll Med, Tainan, Taiwan
[4] Show Chwan Mem Hosp, Dept Orthopaed Surg, Changhua, Taiwan
[5] Natl Cheng Kung Univ Hosp, Natl Cheng Kung Univ, Dept Orthoped, Coll Med, Tainan, Taiwan
[6] Natl Cheng Kung Univ, Dept Publ Hlth, Coll Med, Tainan, Taiwan
[7] China Med Univ, Dept Publ Hlth, Coll Publ Hlth, Taichung, Taiwan
[8] Asia Univ, Dept Healthcare Adm, Coll Med & Hlth Sci, Taichung, Taiwan
[9] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan, Taiwan
[10] E Da Hosp, Dept Orthoped, Kaohsiung, Taiwan
[11] Shou Univ, Coll Med, Sch Med, Kaohsiung, Taiwan
[12] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, 1 Univ Rd, Tainan 701, Taiwan
[13] Natl Cheng Kung Univ, Coll Med, Dept Biochem & Mol Biol, Tainan, Taiwan
关键词
fluoroscopy; radius fractures; screws penetration; ultrasound; volar plating; PROMINENT HARDWARE; SURGICAL-TREATMENT; FRACTURES; PALMAR; COMPLICATIONS; PLATES;
D O I
10.1002/jor.25341
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the accuracy of the fluoroscopic dorsal tangential view (DTV) and an ultrasound (US) examination in detecting dorsal screw penetration during volar distal radius plating. In six fresh cadaveric distal radii, seven periarticular locking screws in two rows for each plate were inserted according to the measured length using a depth gauge and then replaced with another that was 1 and 2 mm longer, respectively. The actual protruded length of each screw was determined using computed tomography (CT) images. The accuracy of US and DTV measurements was determined using the intraclass correlation coefficient (ICC), as both measurements were compared with CT measurements. The ICC of US and DTV was 0.96 and 0.75, respectively, for all screws. After excluding the data for proximal-row screws, the ICC of US remained unchanged at 0.96, and that of DTV improved to 0.86. The ICC of US was significantly higher than that of DTV (p < 0.01). US had a 100% detection rate for screw protrusion of more than 1.0 mm. US examination showed excellent consistency with CT measurements and its accuracy was not affected by screw location. US might thus be a practical tool for detecting dorsal cortex screw penetration during volar distal radius plating.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [11] Diagnosis of dorsal screw penetration after volar plating of a distal radial fracture INTRAOPERATIVE DORSAL TANGENTIAL VIEWS VERSUS 3D FLUOROSCOPY
    Langerhuizen, D. W. G.
    Bergsma, M.
    Selles, C. A.
    Jaarsma, R. L.
    Goslings, J. C.
    Schep, N. W. L.
    Doornberg, J. N.
    BONE & JOINT JOURNAL, 2020, 102B (07): : 874 - 880
  • [12] Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration
    Gurbuz, Yusuf
    Kucuk, Levent
    Gunay, Huseyin
    Ozaksar, Kemal
    Sugun, Tahir Sadik
    Bilge, Okan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (06) : 448 - 450
  • [13] How effective is skyline view for avoiding dorsal cortex penetration in volar plate fixation of intra-articular and dorsal cortex comminuted distal radius fractures
    Ozbek, Emre Anil
    Ayanoglu, Tacettin
    Armangil, Mehmet
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10): : 1684 - 1688
  • [14] Detection of penetration of the dorsal cortex by epiphyseal screws of distal radius volar plates: Anatomical study comparing ultrasound and fluoroscopy
    Vernet, P.
    Durry, A.
    Nicolau, X.
    D'Ambrosio, A.
    Collinet, A.
    Salazar, S. Botero
    Liverneaux, P.
    Diaz, J. J. Hidalgo
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (06) : 911 - 913
  • [15] Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation
    Riddick, A. P.
    Hickey, B.
    White, S. P.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (05) : 407 - 411
  • [16] Influence of training on dorsal tangential radiographic view to detect screw protrusion after anterior plating of the distal radius: a cadaveric study
    Bergsma, Minke
    Obdeijn, Miryam C.
    Janssen, Stein J.
    Bain, Gregory, I
    Jaarsma, Ruurd L.
    Doornberg, Job N.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (08) : 864 - 870
  • [17] The Dorsal Horizon View: Detecting Screw Protrusion at the Distal Radius
    Joseph, Samuel James
    Harvey, Jason N.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (10): : 1691 - 1693
  • [18] The Dorsal Horizon View: Detecting Screw Protrusion at the Distal Radius
    Joseph, S.
    Harvey, J.
    XV CONGRESS OF THE FEDERATION OF THE EUROPEAN SOCIETIES FOR SURGERY OF THE HAND (FESSH), 2010, : 21 - 25
  • [19] Volar and Dorsal Rim Fractures of the Distal Radius
    Slutsky, David J.
    JOURNAL OF WRIST SURGERY, 2016, 5 (01) : 1 - 1
  • [20] Dorsal plating for distal radius fractures
    Tavakolian, JD
    Jupiter, JB
    HAND CLINICS, 2005, 21 (03) : 341 - +