Comparison of ultrasound and dorsal tangential view for dorsal cortex screw penetration in volar plating of the distal radius

被引:5
|
作者
Yang, Jui-Ming [1 ,2 ]
Wang, Chien-Kuo [3 ]
Lin, Wei-Chin [4 ,5 ]
Li, Chung-Yi [6 ,7 ,8 ]
Su, Fong-Chin [1 ,9 ]
Jou, I-Ming [10 ,11 ]
Wu, Po-Ting [1 ,5 ,9 ,12 ,13 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
[2] Tainan ShinLau Christian Hosp, Dept Orthoped, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Dept Radiol, Coll Med, Tainan, Taiwan
[4] Show Chwan Mem Hosp, Dept Orthopaed Surg, Changhua, Taiwan
[5] Natl Cheng Kung Univ Hosp, Natl Cheng Kung Univ, Dept Orthoped, Coll Med, Tainan, Taiwan
[6] Natl Cheng Kung Univ, Dept Publ Hlth, Coll Med, Tainan, Taiwan
[7] China Med Univ, Dept Publ Hlth, Coll Publ Hlth, Taichung, Taiwan
[8] Asia Univ, Dept Healthcare Adm, Coll Med & Hlth Sci, Taichung, Taiwan
[9] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan, Taiwan
[10] E Da Hosp, Dept Orthoped, Kaohsiung, Taiwan
[11] Shou Univ, Coll Med, Sch Med, Kaohsiung, Taiwan
[12] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, 1 Univ Rd, Tainan 701, Taiwan
[13] Natl Cheng Kung Univ, Coll Med, Dept Biochem & Mol Biol, Tainan, Taiwan
关键词
fluoroscopy; radius fractures; screws penetration; ultrasound; volar plating; PROMINENT HARDWARE; SURGICAL-TREATMENT; FRACTURES; PALMAR; COMPLICATIONS; PLATES;
D O I
10.1002/jor.25341
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the accuracy of the fluoroscopic dorsal tangential view (DTV) and an ultrasound (US) examination in detecting dorsal screw penetration during volar distal radius plating. In six fresh cadaveric distal radii, seven periarticular locking screws in two rows for each plate were inserted according to the measured length using a depth gauge and then replaced with another that was 1 and 2 mm longer, respectively. The actual protruded length of each screw was determined using computed tomography (CT) images. The accuracy of US and DTV measurements was determined using the intraclass correlation coefficient (ICC), as both measurements were compared with CT measurements. The ICC of US and DTV was 0.96 and 0.75, respectively, for all screws. After excluding the data for proximal-row screws, the ICC of US remained unchanged at 0.96, and that of DTV improved to 0.86. The ICC of US was significantly higher than that of DTV (p < 0.01). US had a 100% detection rate for screw protrusion of more than 1.0 mm. US examination showed excellent consistency with CT measurements and its accuracy was not affected by screw location. US might thus be a practical tool for detecting dorsal cortex screw penetration during volar distal radius plating.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [21] Dorsal plating for distal radius fractures
    Tavakolian, JD
    Jupiter, JB
    HAND CLINICS, 2005, 21 (03) : 341 - +
  • [22] Volar versus dorsal plating in the management of intra-articular distal radius fractures
    Ruch, DS
    Papadonikolakis, A
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01): : 9 - 16
  • [23] Diaphyseal Screw Prominence in Distal Radius Volar Plating
    Eng, Kevin
    Gil, Stephen
    Page, Richard
    JOURNAL OF WRIST SURGERY, 2020, 9 (03) : 214 - 218
  • [24] The use of dorsal distraction plating for severely comminuted distal radius fractures: A review and comparison to volar plate fixation
    Perlus, R.
    Doyon, J.
    Henry, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : S50 - S55
  • [25] Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures
    Rausch, Sascha
    Marintschev, Ivan
    Graul, Isabel
    Wilharm, Arne
    Klos, Kajetan
    Hofmann, Gunther O.
    Gras, Marc Florian
    ARCHIVES OF TRAUMA RESEARCH, 2015, 4 (02)
  • [26] Efficacy of volar and dorsal plate fixation for unstable dorsal distal radius fractures
    Chen, Chang-Hong
    Zhou, Rong-Kui
    Zhen, Hua-Qing
    Huang, Lei
    Jiao, Ya-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (03): : 4375 - 4380
  • [27] Intraoperative Detection of Screw Penetration Following Volar Plating of the Distal Radius: A Cadaveric Study Comparing Fluoroscopic Imaging and Ultrasound
    Persitz, Jonathan
    Essa, Ahmad
    Shor, Reut
    Faye-Matthies, Norah
    Von Schroeder, Herb
    Chan, Andrea
    Paul, Ryan
    JOURNAL OF WRIST SURGERY, 2024,
  • [28] Distal Radius Fractures: Dorsal Bridge Plating
    Boateng, Henry A.
    Payatakes, Alexander H.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2015, 25 (04) : 282 - 287
  • [29] Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures
    Kumar, Sanjay
    Khan, A. N.
    Sonanis, S. V.
    JOURNAL OF ORTHOPAEDICS, 2016, 13 (04) : 376 - 382
  • [30] Volar locking compression plating versus dorsal plating for fractures of the distal radius. A prospective, randomized study
    Zettl, R. P.
    Clauberg, E.
    Nast-Kolb, D.
    Ruchholtz, S.
    Kuehne, C. A.
    UNFALLCHIRURG, 2009, 112 (08): : 712 - +