Comparison of ultrasound and dorsal tangential view for dorsal cortex screw penetration in volar plating of the distal radius

被引:2
|
作者
Yang, Jui-Ming [1 ,2 ]
Wang, Chien-Kuo [3 ]
Lin, Wei-Chin [4 ,5 ]
Li, Chung-Yi [6 ,7 ,8 ]
Su, Fong-Chin [1 ,9 ]
Jou, I-Ming [10 ,11 ]
Wu, Po-Ting [1 ,5 ,9 ,12 ,13 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
[2] Tainan ShinLau Christian Hosp, Dept Orthoped, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Dept Radiol, Coll Med, Tainan, Taiwan
[4] Show Chwan Mem Hosp, Dept Orthopaed Surg, Changhua, Taiwan
[5] Natl Cheng Kung Univ Hosp, Natl Cheng Kung Univ, Dept Orthoped, Coll Med, Tainan, Taiwan
[6] Natl Cheng Kung Univ, Dept Publ Hlth, Coll Med, Tainan, Taiwan
[7] China Med Univ, Dept Publ Hlth, Coll Publ Hlth, Taichung, Taiwan
[8] Asia Univ, Dept Healthcare Adm, Coll Med & Hlth Sci, Taichung, Taiwan
[9] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan, Taiwan
[10] E Da Hosp, Dept Orthoped, Kaohsiung, Taiwan
[11] Shou Univ, Coll Med, Sch Med, Kaohsiung, Taiwan
[12] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, 1 Univ Rd, Tainan 701, Taiwan
[13] Natl Cheng Kung Univ, Coll Med, Dept Biochem & Mol Biol, Tainan, Taiwan
关键词
fluoroscopy; radius fractures; screws penetration; ultrasound; volar plating; PROMINENT HARDWARE; SURGICAL-TREATMENT; FRACTURES; PALMAR; COMPLICATIONS; PLATES;
D O I
10.1002/jor.25341
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the accuracy of the fluoroscopic dorsal tangential view (DTV) and an ultrasound (US) examination in detecting dorsal screw penetration during volar distal radius plating. In six fresh cadaveric distal radii, seven periarticular locking screws in two rows for each plate were inserted according to the measured length using a depth gauge and then replaced with another that was 1 and 2 mm longer, respectively. The actual protruded length of each screw was determined using computed tomography (CT) images. The accuracy of US and DTV measurements was determined using the intraclass correlation coefficient (ICC), as both measurements were compared with CT measurements. The ICC of US and DTV was 0.96 and 0.75, respectively, for all screws. After excluding the data for proximal-row screws, the ICC of US remained unchanged at 0.96, and that of DTV improved to 0.86. The ICC of US was significantly higher than that of DTV (p < 0.01). US had a 100% detection rate for screw protrusion of more than 1.0 mm. US examination showed excellent consistency with CT measurements and its accuracy was not affected by screw location. US might thus be a practical tool for detecting dorsal cortex screw penetration during volar distal radius plating.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [41] Systematic review: dorsal bridge plating in distal radius fractures
    Drummond I.
    Durand-Hill M.
    Jones N.
    O’Hagan P.J.
    Edwards D.
    MUSCULOSKELETAL SURGERY, 2024, 108 (3) : 359 - 366
  • [42] Dorsal Distraction Plating for Highly Comminuted Distal Radius Fractures
    Lee, Daniel J.
    Elfar, John C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (02): : 355 - 357
  • [43] Variable-Angle Locking Screw Volar Plating of Distal Radius Fractures
    Park, Jung H.
    Hagopian, Jennifer
    Ilyas, Asif M.
    HAND CLINICS, 2010, 26 (03) : 373 - +
  • [44] Skyline view versus intraoperative 3D fluoroscopy for dorsal screw protrusion identification following volar plating in the treatment of distal radial fracture
    Chih-Hsuan Wung
    Wen-Chih Liu
    Lucía Chiquiar
    Jesse B. Jupiter
    Pietro Regazzoni
    Alberto A. Fernández dell’Oca
    Journal of Orthopaedic Surgery and Research, 20 (1)
  • [45] Ultrasound versus computer tomography scanning in detecting screw penetration following volar plating of distal radial fractures
    Sellayee, Saktthi
    Rajappa, Srinivasan
    Pulimi, Rajiv
    Pitani, Ravishankar
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2021, 46 (10) : 1111 - 1112
  • [46] Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study
    Williams, D.
    Singh, J.
    Heidari, N.
    Ahmad, M.
    Noorani, A.
    Di Mascio, L.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2016, 98 (02) : 138 - 142
  • [47] Corrective osteotomy of the distal radius : dorsal or volar approach, closing or opening wedge
    Verhaegen, Filip
    Degreef, Ilse
    De Smet, Luc
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (05): : 604 - 607
  • [48] Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius
    Ring, D
    Prommersberger, K
    Jupiter, JB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08): : 1646 - 1652
  • [49] Comparison of clinical outcomes with and without volar lunate facet fragments in dorsal displaced distal radius fractures
    Obata, Hiroyuki
    Naito, Kiyohito
    Sugiyama, Yoichi
    Nagura, Nana
    Goto, Kenji
    Kaneko, Ayaka
    Kawakita, So
    Kaneko, Kazuo
    SICOT-J, 2021, 7
  • [50] Clinical Outcomes in Distal Radius Fractures Accompanied by Volar Lunate Facet Fragments: A Comparison between Dorsal and Volar Displaced Fractures
    Obata, Hiroyuki
    Naito, Kiyohito
    Kaneko, Ayaka
    Goto, Keniji
    Sugiyama, Yoichi
    Nagura, Nana
    Kawakita, So
    Iwase, Yoshiyuki
    Kaneko, Kazuo
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (04): : 417 - 422