Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
|
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [41] Simultaneous Determination of α-, β- and γ-hexabromocyclododecane Diastereoisomers in Sewage Sludge using Liquid Chromatography Tandem Mass Spectrometry
    Chiriac, Florentina Laura
    Cruceru, Liliana
    Niculescu, Marcela
    Pascu, Luoana Florentina
    Lehr, Carol Blaziu
    Galaon, Toma
    REVISTA DE CHIMIE, 2017, 68 (08): : 1685 - 1689
  • [42] Simultaneous determination of six urinary porphyrins using liquid chromatography-tandem mass spectrometry
    Bu, W
    Myers, N
    McCarty, JD
    O'Neill, T
    Hollar, S
    Stetson, PL
    Sved, DW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (02): : 411 - 423
  • [43] Simultaneous determination of 16 sulfonamides in honey by liquid chromatography/tandem mass spectrometry
    Pang, Guo-Fang
    Cao, Yan-Zhong
    Zhang, Jin-Jie
    Jia, Guang-Qun
    Fan, Chun-Lin
    Li, Xue-Min
    Liu, Yong-Ming
    Li, Zeng-Yin
    Shi, Yu-Qiu
    Journal of AOAC International, 1600, 88 (05): : 1304 - 1311
  • [44] Simultaneous determination of pesticide residues in crops by liquid chromatography with tandem mass spectrometry
    Ishii, Rie
    Takahashi, Kunihiko
    Horie, Masakazu
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2006, 47 (05): : 201 - 212
  • [45] Simultaneous determination of six dialkylphosphates in urine by liquid chromatography tandem mass spectrometry
    Dulaurent, S
    Saint-Marcoux, F
    Marquet, P
    Lachâtre, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 223 - 229
  • [46] Simultaneous determination of aminoglycoside antibiotics in milk by liquid chromatography with tandem mass spectrometry
    Kajita, Hiroko
    Akutsu, Chizuko
    Hatakeyama, Eriko
    Komukai, Takashi
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2008, 49 (03): : 189 - 195
  • [47] Simultaneous determination of 16 sulfonamides in honey by liquid chromatography/tandem mass spectrometry
    Pang, GF
    Cao, YZ
    Zhang, JJ
    Jia, GQ
    Fan, CL
    Li, XM
    Liu, YM
    Li, ZY
    Sin, YQ
    JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (05) : 1304 - 1311
  • [48] Simultaneous determination of 16 hormones in cosmetics by liquid chromatography tandem mass spectrometry
    Chao, Wang
    Qiang, Ma
    Xing, Wang
    Ting, Wu
    Hua, Bai
    Nan, Hao
    Wang Jun-Bing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (09) : 1257 - 1262
  • [49] Determination of ifenprodil in human plasma using liquid chromatography with electrospray tandem mass spectrometry
    Yang Bo
    Chen Yongchuan
    Xiang Rongfeng
    Yang Dan
    Xia Peiyuan
    Liu Songqing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (03) : 322 - 326
  • [50] Determination of Cefotiam in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Du Ping
    Li Peng-Fei
    Liu Hong-Chuan
    Yu Wei-Yue
    Liu Li-Hong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (06) : 876 - 881