Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
|
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [31] Simultaneous determination of enalapril and enalaprilat in human plasma by liquid chromatography-tandem mass spectrometry
    Gu, Q
    Chen, XY
    Zhong, DF
    Wang, YW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 337 - 342
  • [32] Simultaneous determination of methylephedrine and noscapine in human plasma by liquid chromatography-tandem mass spectrometry
    Zhu, L
    Chen, XY
    Zhang, YF
    Yu, HL
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (02): : 175 - 182
  • [33] Simultaneous determination of tryptophan and 8 metabolites in human plasma by liquid chromatography/tandem mass spectrometry
    Boulet, Lysiane
    Faure, Patrice
    Flore, Patrice
    Monteremal, Julien
    Ducros, Veronique
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1054 : 36 - 43
  • [34] Simultaneous determination of chlorpheniramine and pseudoephedrine in human plasma by liquid chromatography-tandem mass spectrometry
    Chen, XY
    Zhang, Y
    Zhong, DF
    BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (04) : 248 - 253
  • [35] Simultaneous determination of buprenorphine, norbuprenorphine and naloxone in human plasma by liquid chromatography/tandem mass spectrometry
    Liu, Yongzhen
    Li, Xiaohua
    Xu, Allan
    Nasser, Azmi F.
    Heidbreder, Christian
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 120 : 142 - 152
  • [36] Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry
    Gallagher, L. M.
    Owen, L. J.
    Keevil, B. G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 : 48 - 56
  • [37] Simultaneous determination of paracetamol and chlorpheniramine in human plasma by liquid chromatography-tandem mass spectrometry
    Celma, C
    Allué, JA
    Pruñonosa, J
    Peraire, C
    Obach, R
    JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) : 77 - 86
  • [38] Simultaneous determination of midazolam and 1′-hydroxymidazolam in human plasma by liquid chromatography with tandem mass spectrometry
    Li, Wenkui
    Luo, Suyi
    Smith, Harold T.
    Tse, Francis L. S.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (08) : 841 - 851
  • [39] Simultaneous determination of fourteen steroid hormone residues in beef samples by liquid chromatography-tandem mass spectrometry
    Zhao, Chaomin
    Yue, Zhenfeng
    Wu, Hui
    Lai, Furao
    ANALYTICAL METHODS, 2014, 6 (19) : 8030 - 8038
  • [40] Simultaneous determination of four fungicide residues in figs using liquid chromatography tandem mass spectrometry
    Lan, Feng
    Wang, Xinyu
    Wang, Xuejing
    Ruan, Yinwei
    Ding, Li
    Liu, Daliang
    Zhang, Tongliang
    Wang, Jianping
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (09)