Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
|
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [21] Simultaneous determination of prochlorperazine and its metabolites in human plasma using isocratic liquid chromatography tandem mass spectrometry
    Tashiro, Masaki
    Naito, Takafumi
    Kagawa, Yoshiyuki
    Kawakami, Junichi
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (06) : 754 - 760
  • [22] Simultaneous determination of azelnidipine and two metabolites in human plasma using liquid chromatography-tandem mass spectrometry
    Kawabata, Kiyoshi
    Urasaki, Yoko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 45 - 52
  • [23] Simultaneous determination of six phenolic constituents of danshen in human serum using liquid chromatography/tandem mass spectrometry
    Li, XC
    Yu, C
    Cai, YB
    Liu, GY
    Jia, JY
    Wang, YP
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01): : 41 - 47
  • [24] Determination of the steroid profile in alternative matrices by liquid chromatography tandem mass spectrometry
    Gomez-Gomez, Alex
    Miranda, Jezid
    Feixas, Georgina
    Arranz Betegon, Angela
    Crispi, Fatima
    Gratacos, Eduard
    Pozo, Oscar J.
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2020, 197
  • [25] Simultaneous determination of hypericin and hyperforin in human plasma with liquid chromatography-tandem mass spectrometry
    Riedel, KD
    Rieger, K
    Martin-Facklam, M
    Mikus, G
    Haefeli, WE
    Burhenne, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 27 - 33
  • [26] Simultaneous determination of metformin and glipizide in human plasma by liquid chromatography-tandem mass spectrometry
    Ding, Cun-Gang
    Zhou, Zhen
    Ge, Qing-Hua
    Zhi, Xiao-Jin
    Ma, Li-Li
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 132 - 138
  • [27] Simultaneous determination of omeprazole and 5′-hydroxyomeprazole in human plasma by liquid chromatography tandem mass spectrometry
    Woolf, EJ
    Matuszewski, BK
    JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) : 229 - 238
  • [28] Simultaneous Determination of Dabigatran, Rivaroxaban, and Apixaban in Human Plasma by Liquid Chromatography/Tandem Mass Spectrometry
    Zhang, Mei
    Moore, Grant A.
    Chin, Paul K. L.
    THERAPEUTIC DRUG MONITORING, 2020, 42 (03) : 473 - 480
  • [30] Simultaneous determination of piroxicam, meloxicam and tenoxicam in human plasma by liquid chromatography with tandem mass spectrometry
    Ji, HY
    Lee, HW
    Kim, YH
    Jeong, DW
    Lee, HS
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 826 (1-2): : 214 - 219