Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
|
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [1] Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry
    Jarow, JP
    Zhao, M
    Yan, X
    Zhao, Y
    Wright, WW
    Zirkin, BR
    JOURNAL OF ANDROLOGY, 2004, : 52 - 52
  • [2] Simultaneous determination of alfentanil and midazolam in human plasma using liquid chromatography and tandem mass spectrometry
    Kim, Thomas
    London, Amy
    Kharasch, Evan D.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (03) : 487 - 493
  • [3] Simultaneous determination of β-blockers in human plasma using liquid chromatography-tandem mass spectrometry
    Umezawa, Hironobu
    Lee, Xiao-Pen
    Arima, Yoshiko
    Hasegawa, Chika
    Izawa, Hikaru
    Kumazawa, Takeshi
    Sato, Keizo
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 702 - 711
  • [4] Simultaneous determination of pyrethroids and their metabolites in human plasma using liquid chromatography tandem mass spectrometry
    Jeong, Daseul
    Kang, Jae Seon
    Kim, Kang Min
    Baek, Seung-Hoon
    Choe, Sanggil
    Pyo, Jaesung
    FORENSIC SCIENCE INTERNATIONAL, 2019, 302
  • [5] Determination of steroid profile in hair by liquid chromatography tandem mass spectrometry
    Gomez-Gomez, Alex
    Pozo, Oscar J.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624 (1624)
  • [6] Simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma using liquid chromatography tandem mass spectrometry
    Gupta, V. K.
    Jain, Rajeev
    Lukram, Ojitkumar
    Agarwal, Shilpi
    Dwivedi, Ashish
    TALANTA, 2011, 83 (03) : 709 - 716
  • [7] Simultaneous determination of hydrochlorothiazide and valsartan in human plasma by liquid chromatography/tandem mass spectrometry
    Liu, Fei
    Zhang, Jundong
    Xu, Yu
    Gao, Shu
    Guo, Qingxiang
    ANALYTICAL LETTERS, 2008, 41 (08) : 1348 - 1365
  • [8] Simultaneous Determination of Tegafur and Gimeracil in Human Plasma by Liquid Chromatography/Tandem Mass Spectrometry
    Yuan Gu
    Rong Lu
    Duanyun Si
    Changxiao Liu
    Analytical Sciences, 2009, 25 : 1211 - 1215
  • [9] Simultaneous determination of nifedipine and dehydronifedipine in human plasma by liquid chromatography tandem mass spectrometry
    Streel, B
    Zimmer, C
    Sibenaler, R
    Ceccato, A
    JOURNAL OF CHROMATOGRAPHY B, 1998, 720 (1-2): : 119 - 128
  • [10] Simultaneous Determination of Tegafur and Gimeracil in Human Plasma by Liquid Chromatography/Tandem Mass Spectrometry
    Gu, Yuan
    Lu, Rong
    Si, Duanyun
    Liu, Changxiao
    ANALYTICAL SCIENCES, 2009, 25 (10) : 1211 - 1215