Risk Factors for Aseptic Loosening After Total Knee Arthroplasty with a Rotating-Hinge Implant A Case-Control Study

被引:19
|
作者
Levent, Ali [1 ,2 ]
Suero, Eduardo M. [1 ,2 ,3 ]
Gehrke, Thorsten [1 ,2 ]
Citak, Mustafa [1 ,2 ]
机构
[1] ENDO Klin Hamburg, Hamburg, Germany
[2] ENDO Klin Hamburg, Dept Orthopaed Surg, Hamburg, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Gen Trauma & Reconstruct Surg, Munich, Germany
来源
关键词
FAILURE;
D O I
10.2106/JBJS.20.00788
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Successful results have been reported in association with the use of a rotating-hinge prosthesis for primary total knee arthroplasty (TKA). The objective of the present study was to identify risk factors for aseptic loosening in patients who underwent primary TKA with rotating-hinge knee prostheses. Methods: The records of 1,235 patients who underwent primary TKA with a rotating-hinge prosthesis at our center were evaluated. A total of 125 patients who underwent revision were further evaluated according to the inclusion and exclusion criteria, and 33 patients who underwent revision because of aseptic loosening were then compared with a group of 30 patients who did not require revision surgery. All data, including radiographic measurements, were obtained from records prior to the primary TKA. Results: On the basis of our review of demographic, anthropometric, clinical, surgical, and radiographic findings, we found that higher body mass index (BMI) was associated with revision. The majority of patients with aseptic loosening had loosening of the femoral component. Furthermore, the inner femoral diameter at 20 cm proximal to the knee joint (on both anteroposterior and lateral images) was found to be predictive of revision among those with aseptic loosening. Receiver operating characteristic curve analysis showed that an inner diameter of the femur of >19 mm on anteroposterior images had a sensitivity of 91% and specificity of 87% for predicting the need for revision surgery in patients with aseptic loosening. Conclusions: This is one of few studies that has focused on determining risk factors for the failure of rotating-hinge prostheses following TKA surgery. Our findings indicate that a novel variable, the inner (diaphyseal) diameter of the femur at the point 20 cm proximal to the knee joint, is an extremely reliable predictor of revision surgery in patients with aseptic loosening.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 50 条
  • [41] AXLE FRACTURE OF A KINEMATIC ROTATING HINGE TOTAL KNEE ARTHROPLASTY WITH ASSOCIATED TIBIAL COMPONENT LOOSENING
    RIES, MD
    DENNIS, DA
    CLAYTON, ML
    JOURNAL OF ORTHOPAEDIC RHEUMATOLOGY, 1994, 7 (02): : 122 - 126
  • [42] Risk Factors for Nerve Injury After Total Hip Arthroplasty: A Case-Control Study
    Shetty, Teena
    Nguyen, Joseph T.
    Wu, Anita
    Sasaki, Mayu
    Bogner, Eric
    Burge, Alissa
    Cogsil, Taylor
    Kim, Esther U.
    Cummings, Kelianne
    Su, Edwin P.
    Lyman, Stephen
    JOURNAL OF ARTHROPLASTY, 2019, 34 (01): : 151 - 156
  • [43] Early aseptic loosening of a mobile-bearing total knee replacement: A case-control study with retrieval analyses
    Kutzner, Ines
    Hallan, Geir
    Hol, Paul Johan
    Furnes, Ove
    Gothesen, Oystein
    Figved, Wender
    Ellison, Peter
    ACTA ORTHOPAEDICA, 2018, 89 (01) : 77 - 83
  • [44] Primary Rotating-Hinge Total Knee Arthroplasty: Good Outcomes at Mid-Term Follow-Up
    Kowalczewski, Jacek
    Marczak, Dariusz
    Synder, Marek
    Sibinski, Marcin
    JOURNAL OF ARTHROPLASTY, 2014, 29 (06): : 1202 - 1206
  • [45] Early aseptic loosening of primary total knee arthroplasty in patients with osteonecrosis of the knee: A case series
    Baek, Ji-Hoon
    Lee, Su Chan
    Ryu, Suengryol
    Ahn, Hye Sun
    Nam, Chang Hyun
    CLINICAL CASE REPORTS, 2022, 10 (12):
  • [46] Recurring intraprosthetic dislocation of rotating-hinge total knee prosthesis. Effect of implant design on intrinsic stability
    Cavaignac, E.
    Tricoire, J. L.
    Pailhe, R.
    Murgier, J.
    Reina, N.
    Chiron, P.
    Laffosse, J. M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (07) : 835 - 837
  • [47] Factors affecting need for manipulation after total knee arthroplasty: a retrospective case-control cohort study
    Porter, Steven B.
    Zhong, Haoyan
    Robards, Christopher B.
    Liu, Jiabin
    Poeran, Jashvant
    Memtsoudis, Stavros
    BRITISH JOURNAL OF ANAESTHESIA, 2021, 126 (01) : E29 - E31
  • [48] Anatomical risk factors for aseptic loosening of full hinge knee prosthesis in primary and revision TKAs
    Linke, Philip
    Wilhelm, Peter
    Levent, Ali
    Gehrke, Thorsten
    Salber, Jochen
    Akkaya, Mustafa
    Suero, Eduardo M.
    Citak, Mustafa
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4299 - 4307
  • [49] Incidence and risk factors for aseptic baseplate loosening of reverse total shoulder arthroplasty
    Bitzer, Alexander
    Rojas, Jorge
    Patten, Ian S.
    Joseph, Jacob
    McFarland, Edward G.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (12) : 2145 - 2152
  • [50] Rotating-hinge prosthesis for aseptic revision knee arthroplasty: A multicentre retrospective study of 127 cases with a mean follow-up of five years
    Houfani, Faycal
    Mainard, Didier
    Rubens-Duval, Brice
    Papin, Pierre-Emmanuel
    Pasquier, Gilles
    Ehlinger, Matthieu
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (03)