Risk Factors for Aseptic Loosening After Total Knee Arthroplasty with a Rotating-Hinge Implant A Case-Control Study

被引:19
|
作者
Levent, Ali [1 ,2 ]
Suero, Eduardo M. [1 ,2 ,3 ]
Gehrke, Thorsten [1 ,2 ]
Citak, Mustafa [1 ,2 ]
机构
[1] ENDO Klin Hamburg, Hamburg, Germany
[2] ENDO Klin Hamburg, Dept Orthopaed Surg, Hamburg, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Gen Trauma & Reconstruct Surg, Munich, Germany
来源
关键词
FAILURE;
D O I
10.2106/JBJS.20.00788
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Successful results have been reported in association with the use of a rotating-hinge prosthesis for primary total knee arthroplasty (TKA). The objective of the present study was to identify risk factors for aseptic loosening in patients who underwent primary TKA with rotating-hinge knee prostheses. Methods: The records of 1,235 patients who underwent primary TKA with a rotating-hinge prosthesis at our center were evaluated. A total of 125 patients who underwent revision were further evaluated according to the inclusion and exclusion criteria, and 33 patients who underwent revision because of aseptic loosening were then compared with a group of 30 patients who did not require revision surgery. All data, including radiographic measurements, were obtained from records prior to the primary TKA. Results: On the basis of our review of demographic, anthropometric, clinical, surgical, and radiographic findings, we found that higher body mass index (BMI) was associated with revision. The majority of patients with aseptic loosening had loosening of the femoral component. Furthermore, the inner femoral diameter at 20 cm proximal to the knee joint (on both anteroposterior and lateral images) was found to be predictive of revision among those with aseptic loosening. Receiver operating characteristic curve analysis showed that an inner diameter of the femur of >19 mm on anteroposterior images had a sensitivity of 91% and specificity of 87% for predicting the need for revision surgery in patients with aseptic loosening. Conclusions: This is one of few studies that has focused on determining risk factors for the failure of rotating-hinge prostheses following TKA surgery. Our findings indicate that a novel variable, the inner (diaphyseal) diameter of the femur at the point 20 cm proximal to the knee joint, is an extremely reliable predictor of revision surgery in patients with aseptic loosening.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 50 条
  • [31] Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up
    Asgeir Gudnason
    Jan Milbrink
    Nils P. Hailer
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1601 - 1607
  • [32] Good Mid-Term Implant Survival of a Novel Single-Design Rotating-Hinge Total Knee Arthroplasty
    Schlechter, Matthias
    Theil, Christoph
    Gosheger, Georg
    Moellenbeck, Burkhard
    Schwarze, Jan
    Puetzler, Jan
    Bockholt, Sebastian
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (19)
  • [33] Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees
    Jae-Hyuk Yang
    Jung-Ro Yoon
    Chi-Hun Oh
    Taik-Sun Kim
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 517 - 523
  • [34] Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees
    Yang, Jae-Hyuk
    Yoon, Jung-Ro
    Oh, Chi-Hun
    Kim, Taik-Sun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 517 - 523
  • [35] Patient-related risk factors leading to aseptic stem loosening in total hip arthroplasty -: A case-control study of 5,035 patients
    Muenger, Peter
    Roeder, Christoph
    Ackermann-Liebrich, Ursula
    Busato, Andre
    ACTA ORTHOPAEDICA, 2006, 77 (04) : 567 - 574
  • [36] Case Report: Failure of Rotating-hinge Total Knee Prosthesis by Disengagement of the Hinge-post Extension
    Biswas, Debdut
    Haughom, Bryan
    Mayle, Robert E., Jr.
    Della Valle, Craig J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (04) : 1389 - 1392
  • [37] Risk factors for nerve injury after total knee arthroplasty: a case control study
    Shetty, T.
    Nguyen, J. T.
    Sasaki, M.
    Wu, A.
    Bogner, E.
    Burge, A.
    Cogsil, T.
    Dalal, A.
    Halvorsen, K.
    Cummings, K.
    Su, E. P.
    Lyman, S.
    NEUROMUSCULAR DISORDERS, 2018, 28 : S24 - S24
  • [38] Revision Total Knee Arthroplasty With a Rotating-Hinge Prosthesis Mated to a Well-Fixed Femoral Sleeve
    Hannon, Charles P.
    Stuart, Michael B.
    Abdel, Matthew P.
    Pagnano, Mark W.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (06): : S270 - S275
  • [39] Risk Factors for Total Knee Arthroplasty Aseptic Revision
    Namba, Robert S.
    Cafri, Guy
    Khatod, Monti
    Inacio, Maria C. S.
    Brox, Timothy W.
    Paxton, Elizabeth W.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 122 - 127
  • [40] Diagnostic value of bone scintigraphy for aseptic loosening after total knee arthroplasty
    Claassen, Leif
    Ettinger, Max
    Plaass, Christian
    Daniilidis, Kiriakos
    Calliess, Tilman
    Ezechieli, Marco