Risk Factors for Aseptic Loosening After Total Knee Arthroplasty with a Rotating-Hinge Implant A Case-Control Study

被引:19
|
作者
Levent, Ali [1 ,2 ]
Suero, Eduardo M. [1 ,2 ,3 ]
Gehrke, Thorsten [1 ,2 ]
Citak, Mustafa [1 ,2 ]
机构
[1] ENDO Klin Hamburg, Hamburg, Germany
[2] ENDO Klin Hamburg, Dept Orthopaed Surg, Hamburg, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Gen Trauma & Reconstruct Surg, Munich, Germany
来源
关键词
FAILURE;
D O I
10.2106/JBJS.20.00788
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Successful results have been reported in association with the use of a rotating-hinge prosthesis for primary total knee arthroplasty (TKA). The objective of the present study was to identify risk factors for aseptic loosening in patients who underwent primary TKA with rotating-hinge knee prostheses. Methods: The records of 1,235 patients who underwent primary TKA with a rotating-hinge prosthesis at our center were evaluated. A total of 125 patients who underwent revision were further evaluated according to the inclusion and exclusion criteria, and 33 patients who underwent revision because of aseptic loosening were then compared with a group of 30 patients who did not require revision surgery. All data, including radiographic measurements, were obtained from records prior to the primary TKA. Results: On the basis of our review of demographic, anthropometric, clinical, surgical, and radiographic findings, we found that higher body mass index (BMI) was associated with revision. The majority of patients with aseptic loosening had loosening of the femoral component. Furthermore, the inner femoral diameter at 20 cm proximal to the knee joint (on both anteroposterior and lateral images) was found to be predictive of revision among those with aseptic loosening. Receiver operating characteristic curve analysis showed that an inner diameter of the femur of >19 mm on anteroposterior images had a sensitivity of 91% and specificity of 87% for predicting the need for revision surgery in patients with aseptic loosening. Conclusions: This is one of few studies that has focused on determining risk factors for the failure of rotating-hinge prostheses following TKA surgery. Our findings indicate that a novel variable, the inner (diaphyseal) diameter of the femur at the point 20 cm proximal to the knee joint, is an extremely reliable predictor of revision surgery in patients with aseptic loosening.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 50 条
  • [1] Is There a Place for Rotating-Hinge Arthroplasty in Knee Revision Surgery for Aseptic Loosening?
    Joshi, Nayana
    Navarro-Quilis, Antonio
    JOURNAL OF ARTHROPLASTY, 2008, 23 (08): : 1204 - 1211
  • [2] A case of an atraumatic implant failure after primary rotating-hinge total knee arthroplasty
    Petitqueux, Lucas
    Verhulst, Karen
    Dauwe, Jan
    Dauwe, Dirk
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (03): : 449 - 451
  • [3] Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implants
    Levent, Ali
    Suero, Eduardo M.
    Gehrke, Thorsten
    Bakhtiari, Iman Godarzi
    Citak, Mustafa
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (01) : 125 - 132
  • [4] Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implants
    Ali Levent
    Eduardo M. Suero
    Thorsten Gehrke
    Iman Godarzi Bakhtiari
    Mustafa Citak
    International Orthopaedics, 2021, 45 : 125 - 132
  • [5] Rotating-hinge Total Knee for Revision Total Knee Arthroplasty
    Bistolfi, Alessandro
    Massazza, Giuseppe
    Rosso, Federica
    Crova, Maurizio
    ORTHOPEDICS, 2012, 35 (03) : E325 - E330
  • [6] Comment on "Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implants"
    Zhang, Yu-Min
    Li, Kun
    Zhang, Bin-Fei
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (03) : 803 - 804
  • [7] Comment on “Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implants”
    Yu-Min Zhang
    Kun Li
    Bin-Fei Zhang
    International Orthopaedics, 2021, 45 : 803 - 804
  • [8] KINEMATIC ROTATING-HINGE TOTAL KNEE ARTHROPLASTY
    RAND, JA
    CHAO, EYS
    STAUFFER, RN
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (04): : 489 - 497
  • [9] Dislocation of rotating-hinge total knee arthroplasty
    Encinas-Ullan, Carlos A.
    Gomez-Cardero, Primitivo
    Ruiz-Perez, Juan S.
    Carlos Rodriguez-Merchan, E.
    EFORT OPEN REVIEWS, 2021, 6 (02) : 107 - 112
  • [10] High Rates of Early Septic Failure, but Low Rates of Aseptic Loosening After Revision Total Knee Arthroplasty With Contemporary Rotating-Hinge Prostheses
    Bornes, Troy D.
    Puri, Simarjeet
    Neitzke, Colin C.
    Chandi, Sonia K.
    Gausden, Elizabeth B.
    Sculco, Peter K.
    Chalmers, Brian P.
    JOURNAL OF ARTHROPLASTY, 2025, 40 (02):