Reliability of real-time continuous glucose monitoring in infants

被引:8
|
作者
Tomotaki, Seiichi [1 ,2 ]
Toyoshima, Katsuaki [1 ]
Shimokaze, Tomoyuki [1 ]
Kawai, Masahiko [2 ]
机构
[1] Kanagawa Childrens Med Ctr, Dept Neonatol, Yokohama, Kanagawa, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Pediat, Kyoto, Japan
关键词
alarm; blood glucose; hypoglycemia; neonate; FOLLOW-UP; PRETERM; HYPOGLYCEMIA; TERM; GLYCEMIA; BABIES; RISK;
D O I
10.1111/ped.13961
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Neonatal hypoglycemia is a common and treatable risk factor for neurological impairment. Real-time continuous glucose monitoring (RT-CGM) can show glucose concentration in real time. Using an RT-CGM alarm, physicians can be alerted and intervene in hypoglycemia. No reports, however, have evaluated the reliability of RT-CGM at low glucose levels in infants. This study therefore investigated the difference between blood glucose (BG) and RT-CGM sensor data at low glucose levels and assessed the optimum method of using a hypoglycemic alarm in infants. Methods We enrolled infants whose glycemic management was difficult. We calculated the mean absolute difference (MAD) and mean absolute relative difference (MARD) between BG and RT-CGM sensor data. We compared the MAD and MARD between the low BG fluctuation and high BG fluctuation groups. Results We used RT-CGM for 12 patients (29 times) and investigated 448 pairs of BG and RT-CGM sensor data. The MAD between these pairs was 9.3 +/- 8.9 mg/dL, and the MARD was 11.5%. The MAD at low glucose was 7.7 +/- 6.0 mg/dL, and the MARD was 16.2%. The MAD and MARD were 6.8 +/- 5.4 mg/dL and 7.8% in the low fluctuation group and 10.1 +/- 9.5 mg/dL and 12.7% in the high fluctuation group, respectively. Conclusions The difference between BG and RT-CGM sensor data changes with the degree of fluctuation in BG. When physicians set the hypoglycemic alarm, consideration of this difference and a change in the alarm setting according to the degree of fluctuation in BG may be useful.
引用
收藏
页码:1001 / 1006
页数:6
相关论文
共 50 条
  • [31] A Feasibility Study to Detect Neonatal Hypoglycemia in Infants of Diabetic Mothers Using Real-Time Continuous Glucose Monitoring
    Nally, Laura Marie
    Bondy, Nicholas
    Doiev, Jasmine
    Buckingham, Bruce A.
    Wilson, Darrell M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (04) : 170 - 176
  • [32] Accuracy and Reliability of Real-Time Continuous Glucose Monitoring in the Intensive Care Unit after Major Abdominal Surgery
    Hagerf , Barbora
    Protus, Marek
    Nemetova, Lenka
    Mraz, Milos
    Haluzik, Martin
    Girman, Peter
    Franekova, Janka
    Svirlochova, Veronika
    Jabor, Antonin
    DIABETES, 2023, 72
  • [33] Impact of real-time continuous glucose monitoring on glucose variability in critically ill patients
    R Brunner
    R Kitzberger
    W Miehsler
    V Fuhrmann
    C Madl
    U Holzinger
    Critical Care, 14 (Suppl 1):
  • [34] The Role of Real-Time Glucose Monitoring
    Bernot, John
    Patel, Manali
    Kirk, Julienne K.
    JOURNAL OF DIABETES & METABOLISM, 2016, 7 (04)
  • [35] Real-Time Continuous Microbiological Monitoring
    Denoya, Claudio
    BIOPHARM INTERNATIONAL, 2016, 29 (10) : 38 - 40
  • [36] Real-time continuous glucose monitoring in preterm infants (REACT): an international, open-label, randomised controlled trial
    Beardsall, Kathryn
    Thomson, Lynn
    Guy, Catherine
    Iglesias-Platas, Isabel
    van Weissenbruch, Mirjam M.
    Bond, Simon
    Allison, Annabel
    Kim, Sungwook
    Petrou, Stavros
    Pantaleo, Beatrice
    Hovorka, Roman
    Dunger, David
    LANCET CHILD & ADOLESCENT HEALTH, 2021, 5 (04): : 265 - 273
  • [37] Real-time continuous glucose monitoring in preterm infants (react): An International, open-label, randomised, controlled trial
    Dinu, Daniela
    Rozance, Paul
    ACTA PAEDIATRICA, 2021, 110 (09) : 2656 - 2657
  • [38] Cost-effectiveness of real time continuous glucose monitoring to target glucose control in preterm infants
    Petrou, Stavros
    Kim, Sungwook
    Bond, Simon
    Allison, Annabel
    Beardsall, Kathryn
    SEMINARS IN PERINATOLOGY, 2021, 45 (03)
  • [39] PERSONAL REAL-TIME CONTINUOUS GLUCOSE MONITORING IN PATIENTS 65 YEARS AND OLDER
    Argento, Nicholas B.
    Nakamura, Katherine
    ENDOCRINE PRACTICE, 2014, 20 (12) : 1297 - 1302
  • [40] The Effect of Real-Time Continuous Glucose Monitoring (RT-CGM) in Prediabetes
    Warnock, Alicia
    Salkind, Sara
    Senicki, Sheri
    Fonda, Stephanie
    Walker, Susan
    Polonsky, William
    Rodbard, David
    Vigersky, Robert
    DIABETES, 2016, 65 : A232 - A232