Cost-effectiveness of real time continuous glucose monitoring to target glucose control in preterm infants

被引:7
|
作者
Petrou, Stavros [1 ]
Kim, Sungwook [1 ]
Bond, Simon [2 ]
Allison, Annabel [2 ]
Beardsall, Kathryn [3 ]
机构
[1] Univ Oxford, Nuffield Dept Primary Care Hlth Sci, Oxford, England
[2] Cambridge Univ Hosp NHS Fdn Trust, Cambridge Clin Trials Unit, Cambridge, England
[3] Univ Cambridge, Dept Paediat, Cambridge, England
关键词
Real time continuous glucose monitoring; Preterm; Neonatal care; Economic evaluation; Cost-effectiveness; INSULIN THERAPY; RISK-FACTOR; SENSOR; HYPERGLYCEMIA; IMPUTATION; HEALTH; DEATH;
D O I
10.1016/j.semperi.2021.151392
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The optimal management of glucose levels in critical care remains an area for research due to the problems of balancing the risks of hyperglycemia versus hypoglycemia. This paper reports the first economic evaluation of real time continuous glucose monitoring to guide the clinical management of preterm infants, based on evidence from the REACT trial. Bivariate regression of costs ( pound, 2016-17 prices) and cases of adequate glucose control, with multiple imputation of missing data, was conducted. When the economic evaluation was restricted to the first week of life, real time continuous glucose monitoring was associated with increased costs and a statistically significant increase in adequate glucose control. When the assessment was performed over a time horizon extending to 36 weeks' corrected gestational age, real time CGM was dominant in health economic terms, i.e. associated with lower costs and better outcomes. These results largely remained robust to a range of sensitivity analyses and sub-group analyses designed to address uncertainty and heterogeneity surrounding the cost-effectiveness outcomes. This study suggests that the use of real time continuous glucose monitoring in preterm infants is associated with a high probability of cost-effectiveness.(c) 2021 Elsevier Inc. All rights reserved.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [1] Real-Time Continuous Glucose Monitoring in Preterm Infants
    Joseph, Rachel
    Rosa, Jenna Hope-Altomari
    NEONATAL NETWORK, 2022, 41 (06): : 376 - 376
  • [2] Cost-Effectiveness of Inpatient Continuous Glucose Monitoring
    Verissimo, David
    Pereira, Beatriz R.
    Vinhais, Joana
    Ivo, Catarina
    Martins, Ana C.
    Silva, Joao N.
    Passos, Dolores
    Lopes, Luis
    de Castro, Joao Jacome
    Marcelino, Mafalda
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [3] Targeting glucose control in preterm infants: pilot studies of continuous glucose monitoring
    Thomson, Lynn
    Elleri, Daniela
    Bond, Simon
    Howlett, James
    Dunger, David B.
    Beardsall, Kathryn
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2019, 104 (04): : F353 - F359
  • [4] Cost-effectiveness analysis of real-time continuous monitoring glucose compared to self-monitoring of blood glucose for diabetes mellitus in Spain
    Garcia-Lorenzo, Borja
    Rivero-Santana, Amado
    Vallejo-Torres, Laura
    Castilla-Rodriguez, Ivan
    Garcia-Perez, Sonia
    Garcia-Perez, Lidia
    Perestelo-Perez, Lilisbeth
    JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2018, 24 (04) : 772 - 781
  • [5] The Cost-Effectiveness of Continuous Glucose Monitoring in Type 1 Diabetes
    Huang, Elbert S.
    O'Grady, Michael
    Basu, Anirban
    Winn, Aaron
    John, Priya
    Lee, Joyce
    Meltzer, David
    Kollman, Craig
    Laffel, Lori
    Tamborlane, William
    Weinzimer, Stuart
    Wysocki, Tim
    DIABETES CARE, 2010, 33 (06) : 1269 - 1274
  • [6] Nationally Subsidized Continuous Glucose Monitoring: A Cost-effectiveness Analysis
    Pease, Anthony J.
    Zoungas, Sophia
    Callander, Emily
    Jones, Timothy W.
    Johnson, Stephanie R.
    Holmes-Walker, D. Jane
    Bloom, David E.
    Davis, Elizabeth A.
    Zomer, Ella
    DIABETES CARE, 2022, 45 (11) : 2611 - 2619
  • [7] Inpatient continuous glucose monitoring vs capillary blood glucose: a cost-effectiveness analysis
    Verissimo, D.
    Vinhais, J.
    Machado, V.
    Silva, S.
    Ivo, C.
    Martins, A. C.
    Silva, J. N.
    Passos, D.
    Lopes, L.
    Castro, J. J.
    Marcelino, M.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S411 - S411
  • [8] Reliability of real-time continuous glucose monitoring in infants
    Tomotaki, Seiichi
    Toyoshima, Katsuaki
    Shimokaze, Tomoyuki
    Kawai, Masahiko
    PEDIATRICS INTERNATIONAL, 2019, 61 (10) : 1001 - 1006
  • [9] Cost-effectiveness of continuous glucose monitoring vs self-monitoring of blood glucose in women with pregestational diabetes
    Niu, Brenda
    Aviram, Amir
    Valent, Amy
    Caughey, Aaron B.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (01) : S389 - S390
  • [10] Validation of the continuous glucose monitoring sensor in preterm infants
    Beardsall, K.
    Vanhaesebrouck, S.
    Ogilvy-Stuart, A. L.
    Vanhole, C.
    vanWeissenbruch, M.
    Midgley, P.
    Thio, M.
    Cornette, L.
    Ossuetta, I.
    Palmer, C. R.
    Iglesias, I.
    de Jong, M.
    Gill, B.
    de Zegher, F.
    Dunger, D. B.