Background Neonatal hypoglycemia is a common and treatable risk factor for neurological impairment. Real-time continuous glucose monitoring (RT-CGM) can show glucose concentration in real time. Using an RT-CGM alarm, physicians can be alerted and intervene in hypoglycemia. No reports, however, have evaluated the reliability of RT-CGM at low glucose levels in infants. This study therefore investigated the difference between blood glucose (BG) and RT-CGM sensor data at low glucose levels and assessed the optimum method of using a hypoglycemic alarm in infants. Methods We enrolled infants whose glycemic management was difficult. We calculated the mean absolute difference (MAD) and mean absolute relative difference (MARD) between BG and RT-CGM sensor data. We compared the MAD and MARD between the low BG fluctuation and high BG fluctuation groups. Results We used RT-CGM for 12 patients (29 times) and investigated 448 pairs of BG and RT-CGM sensor data. The MAD between these pairs was 9.3 +/- 8.9 mg/dL, and the MARD was 11.5%. The MAD at low glucose was 7.7 +/- 6.0 mg/dL, and the MARD was 16.2%. The MAD and MARD were 6.8 +/- 5.4 mg/dL and 7.8% in the low fluctuation group and 10.1 +/- 9.5 mg/dL and 12.7% in the high fluctuation group, respectively. Conclusions The difference between BG and RT-CGM sensor data changes with the degree of fluctuation in BG. When physicians set the hypoglycemic alarm, consideration of this difference and a change in the alarm setting according to the degree of fluctuation in BG may be useful.
机构:
Oregon Hlth & Sci Univ, Div Endocrinol Diabet & Clin Nutr, Portland, OR 97201 USAOregon Hlth & Sci Univ, Div Endocrinol Diabet & Clin Nutr, Portland, OR 97201 USA
Jackson, Melanie A.
Ahmann, Andrew
论文数: 0引用数: 0
h-index: 0
机构:
Oregon Hlth & Sci Univ, Harold Schnitzer Diabet Hlth Ctr, 3181 Southwest Sam Jackson Pk Rd,OP05DC, Portland, OR 97239 USAOregon Hlth & Sci Univ, Div Endocrinol Diabet & Clin Nutr, Portland, OR 97201 USA
Ahmann, Andrew
Shah, Viral N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Colorado, Barbara Davis Ctr Diabet, Anschutz Med Campus, Aurora, CO USAOregon Hlth & Sci Univ, Div Endocrinol Diabet & Clin Nutr, Portland, OR 97201 USA
机构:
Stanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USA
Yale Univ, Dept Pediat, Div Pediat Endocrinol, New Haven, CT 06520 USAStanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USA
Nally, Laura Marie
Bondy, Nicholas
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USAStanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USA
Bondy, Nicholas
Doiev, Jasmine
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USAStanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USA
Doiev, Jasmine
Buckingham, Bruce A.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USAStanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USA
Buckingham, Bruce A.
Wilson, Darrell M.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USAStanford Univ, Dept Pediat, Div Pediat Endocrinol, Stanford, CA 94305 USA