Validation of a liquid chromatographic-tandem mass spectrometric method for the determination of loperamide in human plasma

被引:23
|
作者
Streel, B
Ceccato, A
Klinkenberg, R
Hubert, P
机构
[1] Univ Liege, CHU, Inst Pharm, Analyt Chem Lab, B-4000 Liege, Belgium
[2] Galephar MF, B-6900 Marche En Famenne, Belgium
关键词
loperamide; pharmacokinetics; validation;
D O I
10.1016/j.jchromb.2004.10.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of loperamide in human plasma. Automated solid-phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample is loaded on the DEC filled with endcapped ethyl silica (C2(EC)) and washed twice with water. The analytes are therefore eluted by dispensing methanol. The eluate is then collected and added with ammonium acetate solution in order to inject an aliquot of this final extract in the LC-MS/MS system. On-line LC-MS/MS system using atmospheric pressure chemical ionization (APCI) has been developed for the determination of loperamide. The separation is obtained on a octadecylsilica based stationary phase using a mobile phase consisting in a mixture of methanol and 5 mM ammonium acetate solution (25:75, v/v). Clonazepam is used as internal standard (IS). The MS/MS ion transitions monitored are m/z 477 --> 266 and 316 --> 270 for loperamide and clonazepam, respectively. The most appropriate regression model of the response function as well as the limit of quantitation were first selected during the pre-validation step. These latter criteria were then assessed during the formal validation step. The limit of quantitation (LOQ) was around 50 pg/ml for loperamide. The method was also validated with respect to recovery, precision, trueness, accuracy and linearity. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 273
页数:11
相关论文
共 50 条
  • [1] Development and validation of a liquid chromatographic-tandem mass spectrometric method for the determination of galantamine in human heparinised plasma
    Verhaeghe, T
    Diels, L
    de Vries, R
    De Meulder, M
    de Jong, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 337 - 346
  • [2] Simple determination of huperzine A in human plasma by liquid chromatographic-tandem mass spectrometric method
    Li, Yun-Xia
    Jiang, Xue-Hua
    Lan, Ke
    Wang, Ling
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (01) : 15 - 20
  • [3] Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the determination of cromolyn sodium in human plasma
    Lin, ZPJ
    Abbas, R
    Rusch, LM
    Shum, L
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (01): : 159 - 166
  • [4] Development and validation of a liquid chromatographic-tandem mass spectrometric method for the determination of pibutidine in human urine
    Kato, K
    Jingu, S
    Ogawa, N
    Higuchi, S
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 187 - 193
  • [5] Determination of ranolazine in human plasma by liquid chromatographic-tandem mass spectrometric assay
    Zhao, Limei
    Li, Hao
    Jiang, Yao
    Piao, Riyang
    Li, Pengfei
    Gu, Jingkai
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (08) : 697 - 700
  • [6] Determination of cefaclor in human plasma by a sensitive and specific liquid chromatographic-tandem mass spectrometric method
    Chen, XY
    Zhong, DF
    Huang, B
    Cui, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (01): : 17 - 24
  • [7] Liquid chromatographic-tandem mass spectrometric method for the quantitation of sildenafil in human plasma
    Wang, YW
    Wang, J
    Cui, YM
    Fawcett, JP
    Gu, JK
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 118 - 121
  • [8] High-performance liquid chromatographic-tandem mass spectrometric method for the determination of clemastine in human plasma
    Horváth, V
    Tolokán, A
    Egresi, A
    Pap, T
    Horvai, G
    Balogh-Nernes, K
    Klebovich, I
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 153 - 159
  • [9] A liquid chromatographic-tandem mass spectrometric method for determination of artemether and its metabolite dihydroartemisinin in human plasma
    Hanpithakpong, Warunee
    Kamanikom, Benjamas
    Singhasivanon, Pratap
    White, Nicholas J.
    Day, Nicholas P. J.
    Lindegardh, Niklas
    [J]. BIOANALYSIS, 2009, 1 (01) : 37 - 46
  • [10] A liquid chromatographic-tandem mass spectrometric method for determination of artesunate and its metabolite dihydroartemisinin in human plasma
    Hanpithakpong, W.
    Kamanikom, B.
    Dondorp, A. M.
    Singhasivanon, P.
    White, N. J.
    Day, N. P. J.
    Lindegardh, N.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 61 - 68