Validation of a liquid chromatographic-tandem mass spectrometric method for the determination of loperamide in human plasma

被引:23
|
作者
Streel, B
Ceccato, A
Klinkenberg, R
Hubert, P
机构
[1] Univ Liege, CHU, Inst Pharm, Analyt Chem Lab, B-4000 Liege, Belgium
[2] Galephar MF, B-6900 Marche En Famenne, Belgium
关键词
loperamide; pharmacokinetics; validation;
D O I
10.1016/j.jchromb.2004.10.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of loperamide in human plasma. Automated solid-phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample is loaded on the DEC filled with endcapped ethyl silica (C2(EC)) and washed twice with water. The analytes are therefore eluted by dispensing methanol. The eluate is then collected and added with ammonium acetate solution in order to inject an aliquot of this final extract in the LC-MS/MS system. On-line LC-MS/MS system using atmospheric pressure chemical ionization (APCI) has been developed for the determination of loperamide. The separation is obtained on a octadecylsilica based stationary phase using a mobile phase consisting in a mixture of methanol and 5 mM ammonium acetate solution (25:75, v/v). Clonazepam is used as internal standard (IS). The MS/MS ion transitions monitored are m/z 477 --> 266 and 316 --> 270 for loperamide and clonazepam, respectively. The most appropriate regression model of the response function as well as the limit of quantitation were first selected during the pre-validation step. These latter criteria were then assessed during the formal validation step. The limit of quantitation (LOQ) was around 50 pg/ml for loperamide. The method was also validated with respect to recovery, precision, trueness, accuracy and linearity. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 273
页数:11
相关论文
共 50 条
  • [31] High-throughput liquid chromatographic-tandem mass spectrometric determination of arginine and dimethylated arginine derivatives in human and mouse plasma
    Schwedhelm, Edzard
    Maas, Renke
    Tan-Andresen, Jing
    Schulze, Friedrich
    Riederer, Ulrich
    Boeger, Rainer H.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 851 (1-2): : 211 - 219
  • [32] Simultaneous determination of albendazole and its major active metabolite in human plasma using a sensitive and specific liquid chromatographic-tandem mass spectrometric method
    Chen, XY
    Zhao, LY
    Xu, HY
    Zhong, DF
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (04) : 829 - 836
  • [33] A high-pressure liquid chromatographic-tandem mass spectrometric method for the determination of ethambutol in human plasma, bronchoalveolar lavage fluid, and alveolar cells
    Conte, JE
    Lin, E
    Zhao, YP
    Zurlinden, E
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (02) : 113 - 118
  • [34] Fast liquid chromatographic-tandem mass spectrometric (LC-MS-MS) determination of metformin in plasma samples
    Heinig, K
    Bucheli, F
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) : 1005 - 1011
  • [35] A liquid chromatographic-tandem mass spectrometric method for the analysis of serotonin and related indoles in human whole blood
    Danaceau, JP
    Anderson, GM
    McMahon, WM
    Crouch, DJ
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2003, 27 (07) : 440 - 444
  • [36] Liquid chromatographic/tandem mass spectrometric method for the quantitation of tranilast in human plasma
    Lan, Jing
    Wang, Jian
    Wu, Dan
    Wang, Yingwu
    Fawcett, J. Paul
    Gu, Jingkai
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (22) : 3309 - 3312
  • [37] Liquid chromatographic-tandem mass spectrometric method for the plant lignan 7-hydroxymatairesinol and its potential metabolites in human plasma
    Smeds, A
    Hakala, K
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 793 (02): : 297 - 308
  • [38] Specific, sensitive and accurate liquid chromatographic-tandem mass spectrometric method for the measurement of ribavirin in rat and monkey plasma
    Lin, CC
    Yeh, LT
    Lau, JY
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02): : 241 - 248
  • [39] Development and validation of a liquid chromatographic-tandem mass spectrometric assay for the quantification of the direct acting antivirals glecaprevir and pibrentasvir in plasma
    Garza, Kyana Y.
    Pandey, Aashish
    Marzinke, Mark A.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [40] Liquid chromatographic-electrospray tandem mass spectrometric determination of bisoprolol in human plasma
    Liu, Mingyuan
    Zhang, Dan
    Sun, Yantong
    Wang, Yingwu
    Liu, Zeyuan
    Gu, Jingkai
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (05) : 508 - 513