Validation of a liquid chromatographic-tandem mass spectrometric method for the determination of loperamide in human plasma

被引:23
|
作者
Streel, B
Ceccato, A
Klinkenberg, R
Hubert, P
机构
[1] Univ Liege, CHU, Inst Pharm, Analyt Chem Lab, B-4000 Liege, Belgium
[2] Galephar MF, B-6900 Marche En Famenne, Belgium
关键词
loperamide; pharmacokinetics; validation;
D O I
10.1016/j.jchromb.2004.10.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of loperamide in human plasma. Automated solid-phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample is loaded on the DEC filled with endcapped ethyl silica (C2(EC)) and washed twice with water. The analytes are therefore eluted by dispensing methanol. The eluate is then collected and added with ammonium acetate solution in order to inject an aliquot of this final extract in the LC-MS/MS system. On-line LC-MS/MS system using atmospheric pressure chemical ionization (APCI) has been developed for the determination of loperamide. The separation is obtained on a octadecylsilica based stationary phase using a mobile phase consisting in a mixture of methanol and 5 mM ammonium acetate solution (25:75, v/v). Clonazepam is used as internal standard (IS). The MS/MS ion transitions monitored are m/z 477 --> 266 and 316 --> 270 for loperamide and clonazepam, respectively. The most appropriate regression model of the response function as well as the limit of quantitation were first selected during the pre-validation step. These latter criteria were then assessed during the formal validation step. The limit of quantitation (LOQ) was around 50 pg/ml for loperamide. The method was also validated with respect to recovery, precision, trueness, accuracy and linearity. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 273
页数:11
相关论文
共 50 条
  • [21] Liquid chromatographic tandem mass spectrometric determination of trandolapril in human plasma
    Pistos, C
    Koutsopoulou, M
    Panderi, I
    [J]. ANALYTICA CHIMICA ACTA, 2005, 540 (02) : 375 - 382
  • [22] Development and validation of a liquid chromatographic-tandem mass spectrometric method for the multiplexed quantification of etravirine, maraviroc, raltegravir, and rilpivirine in human plasma and tissue
    Parsons, Teresa L.
    Marzinke, Mark A.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 131 : 333 - 344
  • [23] High-performance liquid chromatographic-tandem mass spectrometric determination of Itraconazole in human plasma for bioavailability and bioequivalence studies
    Choi, YW
    Nam, D
    Kang, KH
    Ha, KW
    Han, IH
    Chang, BK
    Yoon, M
    Lee, J
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2006, 27 (02) : 291 - 294
  • [24] Validation of a liquid chromatographic tandem mass spectrometric method for the determination of sumatriptan in human biological fluids
    Cheng, KN
    Redrup, MJ
    Barrow, A
    Williams, PN
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (03) : 399 - 408
  • [25] Validation of a Liquid Chromatographic/Tandem Mass Spectrometric Method for the Determination of Scopolamine Butylbromide in Human Plasma: Application of the Method to a Bioequivalence Study
    Manfio, Joselia Larger
    dos Santos, Mauricio Bedim
    Jann Favreto, Wagner Alex
    Hoffmann, Fabiane Ines
    Mertin, Adriana Cristina
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2009, 92 (05) : 1366 - 1372
  • [26] Liquid chromatographic-tandem mass spectrometric method for the determination of the neuraminidase inhibitor zanamivir (GG167) in human serum
    Allen, GD
    Brookes, ST
    Barrow, A
    Dunn, JA
    Grosse, CM
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 383 - 393
  • [27] Rapid and selective liquid chromatographic/tandem mass spectrometric method for the determination of fosfomycin in human plasma
    Li, Li
    Chen, Xiaoyan
    Dai, Xiaojian
    Chen, Hui
    Zhong, Dafang
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 171 - 177
  • [28] High-performance liquid chromatographic-tandem mass spectrometric method for the determination of ethionamide in human plasma, bronchoalveolar lavage fluid and alveolar cells
    Conte, JE
    Wang, GF
    Lin, ET
    Zurlinden, E
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02): : 343 - 353
  • [29] Quantification of rifampicin in human plasma and cerebrospinal fluid by a highly sensitive and rapid liquid chromatographic-tandem mass spectrometric method
    Srivastava, Abhishek
    Waterhouse, David
    Ardrey, Alison
    Ward, Stephen A.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 523 - 528
  • [30] A liquid chromatographic-tandem mass spectrometric method for the determination of YM466, a novel Factor Xa inhibitor, in rat plasma
    Mano, Y
    Usui, T
    Kamimura, H
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (04) : 883 - 887