Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs

被引:38
|
作者
Lund, GK
Wendland, MF
Shimakawa, A
Arheden, H
Ståhlberg, F
Higgins, CB
Saeed, M
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[3] Univ Lund Hosp, Dept Radiat Phys, S-22185 Lund, Sweden
[4] GE Med Syst, Milwaukee, WI USA
关键词
coronary vessels; flow dynamics; MR; stenosis or obstruction; magnetic resonance (MR); cine studies; experimental studies; vascular studies; myocardium. blood supply;
D O I
10.1148/radiology.217.2.r00nv10487
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To validate coronary sinus flow measurements for quantification of global left ventricular (LV) perfusion by means of velocity-encoded cine (VEC) magnetic resonance (MR) imaging and flow probes. MATERIALS AND METHODS: Measurements of coronary sinus flow were performed in seven dogs by using VEC MR imaging at baseline, single coronary arterial stenosis, dipyridamole stress, and reactive hyperemia. These measurements were compared with flow probe measurements of coronary blood flow (CBF) in the left anterior descending coronary (LAD) and circumflex (CFX) arteries (CBFLAD+CFX) and coronary sinus. LV blood perfusion was calculated in milliliters per minute per gram from coronary sinus flow, and LV mass was obtained by using VEC and cine MR imaging. LV mass was validated at autopsy. RESULTS: CBFLAD+CFX and coronary sinus flow at VEC MR imaging showed close correlation (r = 0.98, P < .001). The difference between CBFLAD+CFX and MR coronary sinus flow was 3.1 mL/min +/- 8.5 (SD). LV mass at cine MR imaging was not significantly different from that at autopsy (73.2 g +/- 12.8 vs 69.4 g +/- 12.8). At baseline, myocardial perfusion was 0.40 mL/min/g +/- 0.09 at VEC MR imaging, and CBFLAD+CFX was 0.44 ml/min/g +/- 0.08 (not significant). Reactive hyperemia resulted in 2.7- and 2.3-fold increases in coronary sinus flow at VEC MR imaging and flow probe CBFLAD+CFX respectively. CONCLUSION: VEC MR imaging has the potential to measure coronary sinus flow during different physiologic conditions and can serve as a noninvasive modality to quantify global LV perfusion in patients.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [41] Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI
    Sakuma, H
    Kawada, N
    Kubo, H
    Nishide, Y
    Takano, K
    Kato, N
    Takeda, K
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (02) : 346 - 348
  • [42] Manual versus automated vessel edge detection, intra-and interobserver variability in velocity-encoded CINE-MR (VEC-MR) flow measurements
    Henk, CB
    Backfrieder, W
    Grampp, SD
    Liskutin, JE
    Kouwenhoven, M
    VanderGeest, RJ
    RADIOLOGY, 1997, 205 : 1105 - 1105
  • [43] Accurate and reproducible mitral valvular blood flow measurement with three-directional velocity-encoded magnetic resonance imaging
    Westenberg, JJM
    Danilouchkine, MG
    Doornbos, J
    Bax, JJ
    van der Geest, RJ
    Labadie, G
    Lamb, HJ
    Versteegh, MIM
    de Roos, A
    Reiber, JHC
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (04) : 767 - 776
  • [44] New observations from MR velocity-encoded flow measurements concerning diastolic function in constrictive pericarditis
    Bauner, Kerstin
    Horng, A.
    Schmitz, Ch.
    Reiser, M.
    Huber, A.
    EUROPEAN RADIOLOGY, 2010, 20 (08) : 1831 - 1840
  • [45] VELOCITY AND FLOW QUANTITATION IN THE SUPERIOR SAGITTAL SINUS WITH UNGATED AND CINE (GATED) PHASE-CONTRAST MR-IMAGING
    JORDAN, JE
    PELC, NJ
    ENZMANN, DR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01): : 25 - 28
  • [46] Peak velocity and flow quantification validation for sensitivity-encoded phase-contrast MR imaging
    Lew, Calvin D.
    Alley, Marcus T.
    Bammer, Roland
    Spielman, Daniel M.
    Chan, Frandics P.
    ACADEMIC RADIOLOGY, 2007, 14 (03) : 258 - 269
  • [47] New observations from MR velocity-encoded flow measurements concerning diastolic function in constrictive pericarditis
    Kerstin Bauner
    A. Horng
    Ch. Schmitz
    M. Reiser
    A. Huber
    European Radiology, 2010, 20 : 1831 - 1840
  • [48] Validation of rapid velocity encoded cine imaging of a dynamically complex flow field using Turbo block regional interpolation scheme for k space
    Kortright, E
    Doyle, M
    Anayiotos, AS
    Walsh, EG
    Fuisz, AR
    Pohost, GM
    ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (02) : 128 - 134
  • [49] Validation of Rapid Velocity Encoded Cine Imaging of a Dynamically Complex Flow Field Using Turbo Block Regional Interpolation Scheme for k Space
    Eduardo Kortright
    Mark Doyle
    Andreas S. Anayiotos
    Edward G. Walsh
    Anthon R. Fuisz
    Gerald M. Pohost
    Annals of Biomedical Engineering, 2001, 29 : 128 - 134
  • [50] Optic flow computation from cardiac MR tagging using a multiscale differential method a comparative study with velocity-encoded MRI
    Suinesiaputra, A
    Florack, LMJ
    Westenberg, JJM
    Romeny, BMT
    Reiber, JHC
    Lelieveldt, BPF