Accurate and reproducible mitral valvular blood flow measurement with three-directional velocity-encoded magnetic resonance imaging

被引:29
|
作者
Westenberg, JJM
Danilouchkine, MG
Doornbos, J
Bax, JJ
van der Geest, RJ
Labadie, G
Lamb, HJ
Versteegh, MIM
de Roos, A
Reiber, JHC
机构
[1] Leiden Univ, Ctr Med, Div Image Proc, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Leiden Univ, Ctr Med, Dept Radiol, Leiden, Netherlands
[4] Leiden Univ, Ctr Med, Dept Cardiol, Leiden, Netherlands
[5] Leiden Univ, Ctr Med, Dept Cardiothorac Surg, Leiden, Netherlands
关键词
magnetic resonance imaging; mitral valve; flow quantification; image processing;
D O I
10.1081/JCMR-200036108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new method for quantifying the transvalvular flow through the mitral valve (MV) based on three-directional velocity-encoded magnetic resonance imaging (MRI) is presented. For thirty time phases during one cardiac cycle, the three-dimensional (3D) velocity vector field of the blood flow is reconstructed from the MRI measurement. Retrospectively, for each time phase, the MV-plane is indicated manually in the velocity data and the flow through this plane is determined, representing the MV flow. Measurements are performed in 10 healthy volunteers. The new method is compared to the conventional, one-directional velocity-encoded MRI method for which an acquisition plane is positioned at the mitral valve at end-systole and remains fixed during the acquisition. The flow measurements with the new method correlate very well with the flow measured in the aorta (r(P)=0.92, p<0.01), whereas the conventional method shows no statistically significant correlation (r(P) = 0.15, p = 0.68). The low differences between the flow measured at the MV and the flow in the aorta proves high accuracy of the new method. Also, the new method shows very low intra- and interobserver variation, proving the high reproducibility. Three-directional velocity-encoded MRI is a patient-friendly and easy-to-use method suitable for quantifying accurately and reproducibly the transvalvular MV flow.
引用
收藏
页码:767 / 776
页数:10
相关论文
共 50 条
  • [1] QUANTIFICATION OF MITRAL REGURGITATION BY VELOCITY-ENCODED CINE NUCLEAR-MAGNETIC-RESONANCE IMAGING
    FUJITA, N
    CHAZOUILLERES, AF
    HARTIALA, JJ
    OSULLIVAN, M
    HEIDENREICH, P
    KAPLAN, JD
    SAKUMA, H
    FOSTER, E
    CAPUTO, GR
    HIGGINS, CB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (04) : 951 - 958
  • [2] EVALUATION OF MITRAL-STENOSIS WITH VELOCITY-ENCODED CINE-MAGNETIC RESONANCE IMAGING
    HEIDENREICH, PA
    STEFFENS, J
    FUJITA, N
    OSULLIVAN, M
    CAPUTO, GR
    FOSTER, E
    HIGGINS, CB
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (05): : 365 - 369
  • [3] Accuracy of Three-Dimensional Versus Two-Dimensional Echocardiography for Quantification of Aortic Regurgitation and Validation by Three-Dimensional Three-Directional Velocity-Encoded Magnetic Resonance Imaging
    Ewe, See Hooi
    Delgado, Victoria
    van der Geest, Rob
    Westenberg, Jos J. M.
    Haeck, Marlieke L. A.
    Witkowski, Tomasz G.
    Auger, Dominique
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Sieders, Allard
    Siebelink, Hans-Marc J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (04): : 560 - 566
  • [4] QUANTIFICATION OF COLLATERAL BLOOD-FLOW IN COARCTATION OF THE AORTA BY VELOCITY-ENCODED CINE MAGNETIC-RESONANCE-IMAGING
    STEFFENS, JC
    BOURNE, MW
    SAKUMA, H
    OSULLIVAN, M
    HIGGINS, CB
    CIRCULATION, 1994, 90 (02) : 937 - 943
  • [5] THE EVALUATION OF MITRAL-STENOSIS WITH VELOCITY-ENCODED CINE MAGNETIC-RESONANCE
    HEIDENREICH, PA
    STEFFENS, J
    FUJITA, N
    OSULLIVAN, M
    CAPUTO, GR
    FOSTER, E
    HIGGINS, CB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A298 - A298
  • [6] Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow
    Nordmeyer, Sarah
    Riesenkampff, Eugenie
    Messroghli, Daniel
    Kropf, Siegfried
    Nordmeyer, Johannes
    Berger, Felix
    Kuehne, Titus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) : 208 - 216
  • [7] 1065 Three-directional myocardial motion in patients with univentricular hearts using velocity-encoded phase contrast MRI
    Christina E Saikus
    Kartik Sundareswaran
    Resmi Krishnankutty
    John N Oshinski
    Mark A Fogel
    Ajit P Yoganathan
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [8] Three-Directional Evaluation of Mitral Flow in the Rat Heart by Phase-Contrast Cardiovascular Magnetic Resonance
    Skardal, Kristine
    Espe, Emil K. S.
    Zhang, Lili
    Aronsen, Jan Magnus
    Sjaastad, Ivar
    PLOS ONE, 2016, 11 (03):
  • [9] Mitral Valve and Tricuspid Valve Blood Flow: Accurate Quantification with 3D Velocity-encoded MR Imaging with Retrospective Valve Tracking
    Westenberg, Jos J. M.
    Roes, Stijntje D.
    Marsan, Nina Ajmone
    Binnendijk, Nico M. J.
    Doornbos, Joost
    Bax, Jeroen J.
    Reiber, Johan H. C.
    De Roos, Albert
    van der Geest, Robert J.
    RADIOLOGY, 2008, 249 (03) : 792 - 800
  • [10] Four-dimensional velocity encoded magnetic resonance imaging for more accurate blood flow quantification in complex flow
    Sarah Nordmeyer
    Eugénie Riesenkampff
    Felix Berger
    Titus Kuehne
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)