Accurate and reproducible mitral valvular blood flow measurement with three-directional velocity-encoded magnetic resonance imaging

被引:29
|
作者
Westenberg, JJM
Danilouchkine, MG
Doornbos, J
Bax, JJ
van der Geest, RJ
Labadie, G
Lamb, HJ
Versteegh, MIM
de Roos, A
Reiber, JHC
机构
[1] Leiden Univ, Ctr Med, Div Image Proc, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Leiden Univ, Ctr Med, Dept Radiol, Leiden, Netherlands
[4] Leiden Univ, Ctr Med, Dept Cardiol, Leiden, Netherlands
[5] Leiden Univ, Ctr Med, Dept Cardiothorac Surg, Leiden, Netherlands
关键词
magnetic resonance imaging; mitral valve; flow quantification; image processing;
D O I
10.1081/JCMR-200036108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new method for quantifying the transvalvular flow through the mitral valve (MV) based on three-directional velocity-encoded magnetic resonance imaging (MRI) is presented. For thirty time phases during one cardiac cycle, the three-dimensional (3D) velocity vector field of the blood flow is reconstructed from the MRI measurement. Retrospectively, for each time phase, the MV-plane is indicated manually in the velocity data and the flow through this plane is determined, representing the MV flow. Measurements are performed in 10 healthy volunteers. The new method is compared to the conventional, one-directional velocity-encoded MRI method for which an acquisition plane is positioned at the mitral valve at end-systole and remains fixed during the acquisition. The flow measurements with the new method correlate very well with the flow measured in the aorta (r(P)=0.92, p<0.01), whereas the conventional method shows no statistically significant correlation (r(P) = 0.15, p = 0.68). The low differences between the flow measured at the MV and the flow in the aorta proves high accuracy of the new method. Also, the new method shows very low intra- and interobserver variation, proving the high reproducibility. Three-directional velocity-encoded MRI is a patient-friendly and easy-to-use method suitable for quantifying accurately and reproducibly the transvalvular MV flow.
引用
收藏
页码:767 / 776
页数:10
相关论文
共 50 条
  • [31] Flow-sensitive four-dimensional velocity-encoded magnetic resonance imaging reveals abnormal blood flow patterns in the aorta and pulmonary trunk of patients with transposition
    Riesenkampff, Eugenie
    Nordmeyer, Sarah
    Al-Wakeel, Nadya
    Kropf, Siegfried
    Kutty, Shelby
    Berger, Felix
    Kuehne, Titus
    CARDIOLOGY IN THE YOUNG, 2014, 24 (01) : 47 - 53
  • [32] Risk factor of radiation pneumonitis - Assessment with velocity-encoded cine magnetic resonance imaging of pulmonary artery
    Muryama, S
    Akamine, T
    Sakai, S
    Oshiro, Y
    Kakinohana, Y
    Soeda, H
    Toita, T
    Adachi, G
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (02) : 204 - 208
  • [33] QUANTITATION OF CARDIAC-OUTPUT WITH VELOCITY-ENCODED, PHASE-DIFFERENCE MAGNETIC-RESONANCE-IMAGING
    HUNDLEY, WG
    LI, HF
    HILLIS, LD
    MESHACK, BM
    LANGE, RA
    WILLARD, JE
    LANDAU, C
    PESHOCK, RM
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (17): : 1250 - 1255
  • [34] Pulse wave dynamics in the carotid artery: assessment with high field velocity-encoded magnetic resonance imaging
    Kroner, E. S. J.
    Lamb, H. J.
    Siebelink, H. J.
    Wall, E. E.
    Van der Grond, J.
    Van Buchem, M. A.
    De Roos, A.
    Westenberg, J. J. M.
    EUROPEAN HEART JOURNAL, 2012, 33 : 257 - 257
  • [35] Evaluation of flow volume and flow patterns in the patent false lumen of chronic aortic dissections using velocity-encoded cine magnetic resonance imaging
    Inoue, T
    Watanabe, S
    Sakurada, H
    Ono, K
    Urano, M
    Hijikata, Y
    Saito, I
    Masuda, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (10): : 760 - 764
  • [36] Measurement of coronary blood flow velocity during handgrip exercise using breath-hold velocity encoded cine magnetic resonance imaging
    Globits, S
    Sakuma, H
    Shimakawa, A
    Foo, TKF
    Higgins, CB
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (02): : 234 - &
  • [37] MEASUREMENT OF TOTAL AND UNILATERAL RENAL BLOOD-FLOW BY OBLIQUE-ANGLE VELOCITY-ENCODED 2D-CINE MAGNETIC-RESONANCE ANGIOGRAPHY
    LUNDIN, B
    COOPER, TG
    MEYER, RA
    POTCHEN, EJ
    MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 51 - 59
  • [38] Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements
    Greil, G
    Geva, T
    Maier, SE
    Powell, AJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) : 47 - 54
  • [39] QUANTIFICATION OF LEFT-TO-RIGHT ATRIAL SHUNTS WITH VELOCITY-ENCODED CINE NUCLEAR-MAGNETIC-RESONANCE IMAGING
    BRENNER, LD
    CAPUTO, GR
    MOSTBECK, G
    STEIMAN, D
    DULCE, M
    CHEITLIN, MD
    OSULLIVAN, M
    HIGGINS, CB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (05) : 1246 - 1250
  • [40] Assessment of Pulmonary Arterial Pressure in Children with Congenital Heart Disease by Velocity-Encoded Cine Magnetic Resonance Imaging
    Sugimoto, Masaya
    Kajino, Hiroki
    Kajihama, Aya
    Nakau, Kouichi
    Azuma, Hiroshi
    CIRCULATION, 2012, 126 (21)