Accurate and reproducible mitral valvular blood flow measurement with three-directional velocity-encoded magnetic resonance imaging

被引:29
|
作者
Westenberg, JJM
Danilouchkine, MG
Doornbos, J
Bax, JJ
van der Geest, RJ
Labadie, G
Lamb, HJ
Versteegh, MIM
de Roos, A
Reiber, JHC
机构
[1] Leiden Univ, Ctr Med, Div Image Proc, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Leiden Univ, Ctr Med, Dept Radiol, Leiden, Netherlands
[4] Leiden Univ, Ctr Med, Dept Cardiol, Leiden, Netherlands
[5] Leiden Univ, Ctr Med, Dept Cardiothorac Surg, Leiden, Netherlands
关键词
magnetic resonance imaging; mitral valve; flow quantification; image processing;
D O I
10.1081/JCMR-200036108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new method for quantifying the transvalvular flow through the mitral valve (MV) based on three-directional velocity-encoded magnetic resonance imaging (MRI) is presented. For thirty time phases during one cardiac cycle, the three-dimensional (3D) velocity vector field of the blood flow is reconstructed from the MRI measurement. Retrospectively, for each time phase, the MV-plane is indicated manually in the velocity data and the flow through this plane is determined, representing the MV flow. Measurements are performed in 10 healthy volunteers. The new method is compared to the conventional, one-directional velocity-encoded MRI method for which an acquisition plane is positioned at the mitral valve at end-systole and remains fixed during the acquisition. The flow measurements with the new method correlate very well with the flow measured in the aorta (r(P)=0.92, p<0.01), whereas the conventional method shows no statistically significant correlation (r(P) = 0.15, p = 0.68). The low differences between the flow measured at the MV and the flow in the aorta proves high accuracy of the new method. Also, the new method shows very low intra- and interobserver variation, proving the high reproducibility. Three-directional velocity-encoded MRI is a patient-friendly and easy-to-use method suitable for quantifying accurately and reproducibly the transvalvular MV flow.
引用
收藏
页码:767 / 776
页数:10
相关论文
共 50 条
  • [21] Tricuspid valve magnetic resonance imaging phase contrast velocity-encoded flow quantification for follow up of tetralogy of Fallot
    Greenberg, S. Bruce
    Shah, Chetan C.
    Bhutta, Sadaf T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (08): : 861 - 865
  • [22] cation of Mitral Regurgitation by Real-Time Three-Dimensional Echocardiography: Head-to-Head Comparison With Three-Dimensionaol Velocity-Encoded Magnetic Resonance Imaging
    Marsan, Nina Ajmone
    Westenberg, Jos J. M.
    Ypenburg, Claudia
    Delgado, Victoria
    van Bommel, Rutger J.
    Roes, Stijntje D.
    van der Geest, Rob J.
    van der Wall, Ernst E.
    Schalij, Martin J.
    Bax, Jeroen J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A273 - A273
  • [23] Tricuspid valve magnetic resonance imaging phase contrast velocity-encoded flow quantification for follow up of tetralogy of Fallot
    S. Bruce Greenberg
    Chetan C. Shah
    Sadaf T. Bhutta
    The International Journal of Cardiovascular Imaging, 2008, 24 : 861 - 865
  • [24] Spline-based cardiac motion tracking using velocity-encoded magnetic resonance imaging
    Bergvall, Erik
    Hedstrom, Erik
    Bloch, Karin Markenroth
    Arheden, Hakan
    Sparr, Gunnar
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (08) : 1045 - 1053
  • [25] Coronary sinus flow measurement by velocity-encoded cine MR imaging: Validation by Doppler flow probes
    Lund, GK
    Wendland, MF
    Shimakawa, A
    Higgins, B
    Saeed, M
    CIRCULATION, 1999, 100 (18) : 457 - 457
  • [26] 1086 Accurate quantification of simultaneous mitral and tricuspid blood flow using 3D velocity-encoded MRI with retrospective valve tracking
    Jos JM Westenberg
    Stijntje D Roes
    Albert de Roos
    Nico MJ Binnendijk
    Joost Doornbos
    Jeroen J Bax
    Johan HC Reiber
    Rob J van der Geest
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [27] Quantification of Mechanical Ventricular Dyssynchrony: Direct Comparison of Velocity-Encoded and Cine Magnetic Resonance Imaging
    Muellerleile, K.
    Baholli, L.
    Groth, M.
    Koopmann, K.
    Barmeyer, A.
    Gosau, N.
    Ventura, R.
    Rostock, T.
    Koester, R.
    Adam, G.
    Willems, S.
    Lund, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (06): : 554 - 560
  • [28] Measurement of collateral blood flow in a porcine model of aortic coarctation by velocity-encoded cine MRI
    Chernoff, DM
    Derugin, N
    Rajasinghe, HA
    Hanley, FL
    Higgins, CB
    Gooding, CA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 557 - 563
  • [29] Flow Assessment Through Four Heart Valves Simultaneously Using 3-Dimensional 3-Directional Velocity-Encoded Magnetic Resonance Imaging With Retrospective Valve Tracking in Healthy Volunteers and Patients With Valvular Regurgitation
    Roes, Stijntje D.
    Hammer, Sebastiaan
    van der Geest, Rob J.
    Marsan, Nina Ajmone
    Bax, Jeroen J.
    Lamb, Hildo J.
    Reiber, Johan H. C.
    de Roos, Albert
    Westenberg, Jos J. M.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (10) : 669 - 675
  • [30] Simultaneous assessment of pulmonic and systemic flow (Qp/Qs) by velocity-encoded, phase-difference magnetic resonance imaging.
    Lasic, Z
    Bolon, D
    Licato, P
    Comeau, C
    Milet, S
    Knezevic, D
    Ilic, V
    Kokolis, S
    Dangas, G
    Coplan, N
    Wolff, SD
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 125H - 125H