Accuracy of Three-Dimensional Versus Two-Dimensional Echocardiography for Quantification of Aortic Regurgitation and Validation by Three-Dimensional Three-Directional Velocity-Encoded Magnetic Resonance Imaging

被引:47
|
作者
Ewe, See Hooi [1 ,2 ]
Delgado, Victoria [1 ]
van der Geest, Rob [3 ]
Westenberg, Jos J. M. [3 ]
Haeck, Marlieke L. A. [1 ]
Witkowski, Tomasz G. [1 ]
Auger, Dominique [1 ]
Marsan, Nina Ajmone [1 ]
Holman, Eduard R. [1 ]
de Roos, Albert [3 ]
Schalij, Martin J. [1 ]
Bax, Jeroen J. [1 ]
Sieders, Allard [4 ]
Siebelink, Hans-Marc J. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
[2] Natl Heart Ctr, Dept Cardiol, Singapore, Singapore
[3] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
[4] Rijnland Ziekenhuis, Dept Cardiol, Leiderdorp, Netherlands
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2013年 / 112卷 / 04期
关键词
VENA CONTRACTA AREA; FLOW CONVERGENCE METHOD; EUROPEAN-ASSOCIATION; RECOMMENDATIONS; SEVERITY; VALVE; GUIDELINES; COMMITTEE;
D O I
10.1016/j.amjcard.2013.04.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quantitative assessment of aortic regurgitation (AR) remains challenging. The present study evaluated the accuracy of 2-dimensional (2D) and 3-dimensional (3D) transthoracic echocardiography (TTE) for AR quantification, using 3D 3-directional velocity-encoded magnetic resonance imaging (VE-MRI) as the reference method. Thirty-two AR patients were included. With color Doppler TTE, 2D effective regurgitant orifice area (EROA) was calculated using the proximal isovelocity surface area method. From the 3D TTE multiplanar reformation data, 3D-EROA was, calculated by planimetry of the vena contracta. Regurgitant volumes (RVol) were obtained by multiplying the 2D-EROA and 3D-EROA by the velocity-time integral of AR jet and compared with that obtained using VE-MRI. For the entire population, 3D TTE RVol demonstrated a strong correlation and good agreement with VE-MRI RVol (r = 0.94 and -13.6 to 15.6 ml/beat, respectively), whereas 2D TTE RVol showed a modest correlation and large limits of agreement with VE-MRI (r = 0.70 and -22.2 to 32.8 ml/beat, respectively). Eccentric jets were noted in 16 patients (50%). In these patients, 3D TTE demonstrated an excellent correlation (r = 0.95) with VE-MRI, a small bias (0.1 ml/beat) and narrow limits of agreement (-18.7 to 18.8 ml/beat). Finally, the kappa agreement between 3D TTE and VE-MRI for grading of AR severity was good (k = 0.96), whereas the kappa agreement between 2D TTE and VE-MRI was suboptimal (k = 0.53). In conclusion, AR RVol quantification using 3D TTE is accurate, and its advantage over 2D TTE is particularly evident in patients with eccentric jets. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:560 / 566
页数:7
相关论文
共 50 条
  • [1] cation of Mitral Regurgitation by Real-Time Three-Dimensional Echocardiography: Head-to-Head Comparison With Three-Dimensionaol Velocity-Encoded Magnetic Resonance Imaging
    Marsan, Nina Ajmone
    Westenberg, Jos J. M.
    Ypenburg, Claudia
    Delgado, Victoria
    van Bommel, Rutger J.
    Roes, Stijntje D.
    van der Geest, Rob J.
    van der Wall, Ernst E.
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A273 - A273
  • [2] Right ventricular imaging by two-dimensional and three-dimensional echocardiography
    Mangion, Judy R.
    [J]. CURRENT OPINION IN CARDIOLOGY, 2010, 25 (05) : 423 - 429
  • [3] In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI
    Rengier, Fabian
    Delles, Michael
    Unterhinninghofen, Roland
    Ley, Sebastian
    Mueller-Eschner, Matthias
    Partovi, Sasan
    Geisbuesch, Philipp
    Dillmann, Ruediger
    Kauczor, Hans-Ulrich
    von Tengg-Kobligk, Hendrik
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 1999 - 2008
  • [4] Left Ventricular Diastolic Function Assessment From Three-Dimensional Three-Directional Velocity-Encoded MRI With Retrospective Valve Tracking
    Brandts, Anne
    Bertini, Matteo
    van Dijk, Evert-Jan
    Delgado, Victoria
    Marsan, Nina Ajmone
    van der Geest, Rob J.
    Siebelink, Hans-Marc J.
    de Roos, Albert
    Bax, Jeroen J.
    Westenberg, Jos J. M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (02) : 312 - 319
  • [5] In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI
    Fabian Rengier
    Michael Delles
    Roland Unterhinninghofen
    Sebastian Ley
    Matthias Müller-Eschner
    Sasan Partovi
    Philipp Geisbüsch
    Rüdiger Dillmann
    Hans-Ulrich Kauczor
    Hendrik von Tengg-Kobligk
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1999 - 2008
  • [6] Three-dimensional versus two-dimensional imaging for laparoscopic suturing
    Kum, CK
    Goh, P
    Alexander, DJ
    Moochala, S
    [J]. BRITISH JOURNAL OF SURGERY, 1997, 84 (01) : 35 - 35
  • [7] Three-Dimensional Color Doppler Echocardiography Versus Two-Dimensional Derived Method in the Quantification of Tricuspid Regurgitation Orifice Area
    Chen, T. -E.
    Kwon, S. H.
    Sarano, M. E.
    Biers, A. L.
    Moen, J. M.
    Nadolny, A. M.
    OMeara, K. W.
    Wong, B. F.
    Mankad, S. V.
    [J]. CARDIOLOGY, 2012, 121 (02) : 98 - 99
  • [8] Three-dimensional echocardiography in mitral regurgitation
    Laskari, CV
    Masani, ND
    Pandian, NG
    [J]. CORONARY ARTERY DISEASE, 1996, 7 (03) : 206 - 210
  • [9] Quantification of Mitral Regurgitation by General Imaging Three-Dimensional Quantification: Feasibility and Accuracy
    Wang, Wugang
    Lin, Qiongwen
    Wu, Weichun
    Jiang, Yong
    Lan, Tingyu
    Wang, Hao
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (03) : 268 - 276
  • [10] Two-dimensional versus three-dimensional CT scan for aortic measurement
    Dillavou, ED
    Buck, DG
    Muluk, SC
    Makaroun, MS
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (03) : 531 - 538