Two-dimensional versus three-dimensional CT scan for aortic measurement

被引:0
|
作者
Dillavou, ED
Buck, DG
Muluk, SC
Makaroun, MS
机构
[1] Univ Pittsburgh, Med Ctr, Div Vasc Surg, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Med Ctr, Div Intervent Radiol, Pittsburgh, PA 15260 USA
关键词
abdominal aortic aneurysm; endovascular repair; aortic measurement; neck diameter; sac diameter; computed tomography; 3D reconstruction;
D O I
10.1583/1545-1550(2003)010<0531:TVTCSF>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To examine if 3-dimensional (3D) reconstructions of computed tomographic (CT) data, by imaging perpendicular to blood flow, can improve aortic diameter measurement accuracy over axial (2D) CT. Methods: Two independent, blinded observers used electronic calipers to measure the minor axis and the line perpendicular to it on 40 2.5-mm 2D CT scans from 31 patients. A circular electronic tool was used to estimate diameters on 3D reconstructions from the same 40 scans. Measurements of the aortic neck were obtained 5 mm below the renal arteries and the widest slice of the aneurysm was used to measure sac diameter. Only the minor axis was measured at the iliac arteries immediately above the left (LI) and right (RI) iliac bifurcations. Datasets were compared with an intraclass correlation coefficient (ICC), Bland and Altman variation assessments, and absolute differences. Results: ICC between 2D and 3D scans demonstrated high correlation with 2D minor axis measurements (neck=0.9282, sac=0.8956, RI=0.8755, LI=0.7381). 3D to 2D major axis cor relation was lower (neck=0.6388, sac=0.8995). Variation between 3D and 2D minor axis measurements was low (0.51-mm average variation from the mean for the minor axis and 1.30-mm variation for the major axis). Average absolute difference between 3D and 2D diameters was 1.01 mm (minor axis) versus 2.61 mm (major axis). Interobserver correlation was highest for sac measurements both in 2D minor axis (ICC=0.8990) and 3D (ICC=0.9518). Conclusions: Minor axis measurements on axial CT scan can substitute for diameters obtained from 3D reconstructions in most clinical situations.
引用
收藏
页码:531 / 538
页数:8
相关论文
共 50 条
  • [1] Three-dimensional versus two-dimensional ultrasound measurement of follicular volume: are they comparable?
    Ahmed Amer
    Mohamad Eid Hammadeh
    Mohamed Kolkailah
    Abdel-Al Ghandour
    [J]. Archives of Gynecology and Obstetrics, 2003, 268 (3) : 155 - 157
  • [2] Two-dimensional versus three-dimensional measurement of infant cervical active motion
    Castle, Kimberly B.
    Kernozek, Thomas W.
    Warren, Emily
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (06) : 805 - 817
  • [3] Two-dimensional versus three-dimensional cell counting
    Selemon, LD
    Rajkowska, G
    [J]. BIOLOGICAL PSYCHIATRY, 2002, 51 (10) : 838 - 840
  • [4] Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms
    Pitoulias, Georgios A.
    Donas, Konstantinos P.
    Schulte, Stefan
    Aslanidou, Eleni A.
    Papadimitriou, Dimitrios K.
    [J]. ACTA RADIOLOGICA, 2011, 52 (03) : 317 - 323
  • [5] Two-dimensional versus three-dimensional morphometry of monogenoidean sclerites
    Galli, Paolo
    Strona, Giovanni
    Villa, Anna Maria
    Benzoni, Francesca
    Stefani, Fabrizio
    Doglia, Silvia Maria
    Kritsky, Delane C.
    [J]. INTERNATIONAL JOURNAL FOR PARASITOLOGY, 2007, 37 (3-4) : 449 - 456
  • [6] Three-dimensional versus two-dimensional imaging for laparoscopic suturing
    Kum, CK
    Goh, P
    Alexander, DJ
    Moochala, S
    [J]. BRITISH JOURNAL OF SURGERY, 1997, 84 (01) : 35 - 35
  • [7] Three-Dimensional Versus Two-Dimensional Laparoscopic Right Hemicolectomy
    Curro, Giuseppe
    Cogliandolo, Andrea
    Bartolotta, Marcello
    Navarra, Giuseppe
    [J]. JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2016, 26 (03): : 213 - 217
  • [8] Two-Dimensional Versus Three-Dimensional Computed Tomography Reply
    Lindenhovius, Anneluuk
    Ring, David
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (03): : 513 - 514
  • [9] Comparison on two-dimensional and three-dimensional imaging characteristics and quality of a whole body PET-CT scan
    Leon, A. Fernandez
    Gamez, C.
    Benitez, A.
    Lorenzo, C.
    Massuet, C.
    Alvarez, D.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S316 - S316
  • [10] A three-dimensional model of the mandible using two-dimensional CT images
    Mutlu-Sagesen, L
    Toroslu, R
    Parnas, L
    Suca, S
    [J]. PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2778 - 2781