Two-dimensional versus three-dimensional CT scan for aortic measurement

被引:0
|
作者
Dillavou, ED
Buck, DG
Muluk, SC
Makaroun, MS
机构
[1] Univ Pittsburgh, Med Ctr, Div Vasc Surg, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Med Ctr, Div Intervent Radiol, Pittsburgh, PA 15260 USA
关键词
abdominal aortic aneurysm; endovascular repair; aortic measurement; neck diameter; sac diameter; computed tomography; 3D reconstruction;
D O I
10.1583/1545-1550(2003)010<0531:TVTCSF>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To examine if 3-dimensional (3D) reconstructions of computed tomographic (CT) data, by imaging perpendicular to blood flow, can improve aortic diameter measurement accuracy over axial (2D) CT. Methods: Two independent, blinded observers used electronic calipers to measure the minor axis and the line perpendicular to it on 40 2.5-mm 2D CT scans from 31 patients. A circular electronic tool was used to estimate diameters on 3D reconstructions from the same 40 scans. Measurements of the aortic neck were obtained 5 mm below the renal arteries and the widest slice of the aneurysm was used to measure sac diameter. Only the minor axis was measured at the iliac arteries immediately above the left (LI) and right (RI) iliac bifurcations. Datasets were compared with an intraclass correlation coefficient (ICC), Bland and Altman variation assessments, and absolute differences. Results: ICC between 2D and 3D scans demonstrated high correlation with 2D minor axis measurements (neck=0.9282, sac=0.8956, RI=0.8755, LI=0.7381). 3D to 2D major axis cor relation was lower (neck=0.6388, sac=0.8995). Variation between 3D and 2D minor axis measurements was low (0.51-mm average variation from the mean for the minor axis and 1.30-mm variation for the major axis). Average absolute difference between 3D and 2D diameters was 1.01 mm (minor axis) versus 2.61 mm (major axis). Interobserver correlation was highest for sac measurements both in 2D minor axis (ICC=0.8990) and 3D (ICC=0.9518). Conclusions: Minor axis measurements on axial CT scan can substitute for diameters obtained from 3D reconstructions in most clinical situations.
引用
收藏
页码:531 / 538
页数:8
相关论文
共 50 条
  • [41] BLADDER VOLUME DETERMINATION: TWO-DIMENSIONAL VERSUS THREE-DIMENSIONAL TRANSVAGINAL ULTRASOUND
    Liang, Ching-Chung
    Wei, Tien-Yung
    Chang, Shuenn-Dhy
    Hsieh, Ching-Chang
    [J]. TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2009, 48 (03): : 258 - 261
  • [42] Three-dimensional versus two-dimensional ultrasonographic assessment of peripheral enthesitis in spondylarthritis
    Oriane Mérot
    Pascale Guillot
    Yves Maugars
    Benoit Le Goff
    [J]. Clinical Rheumatology, 2014, 33 : 131 - 135
  • [43] Three-dimensional versus two-dimensional laparoscopy for cholecystectomy in a canine cadaveric study
    Azuma, Kazushi
    Monnet, Eric
    [J]. VETERINARY SURGERY, 2024, 53 (04) : 695 - 700
  • [44] Three-dimensional versus two-dimensional transesophageal echocardiography in mitral valve repair
    Garcia-Orta, Rocio
    Moreno, Eduardo
    Vidal, Matilde
    Ruiz-Lopez, Fuensanta
    Oyonarte, Jose M.
    Lara, Juan
    Moreno, Teodoro
    Garcia-Fernandezd, Miguel A.
    Azpitarte, Jose
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (01) : 4 - 12
  • [45] Two-Dimensional Versus Three-Dimensional Preoperative Planning in Total Hip Arthroplasty
    Fontalis, Andreas
    Yasen, Adam T.
    Kayani, Babar
    Luo, Tianyi David
    Mancino, Fabio
    Magan, Ahmed
    Plastow, Ricci
    Haddad, Fares S.
    [J]. JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S80 - S87
  • [46] Fetal lip and primary palate: Three-dimensional versus two-dimensional US
    Johnson, DD
    Pretorius, DH
    Budorick, NE
    Jones, MC
    Lou, KV
    James, GM
    Nelson, TR
    [J]. RADIOLOGY, 2000, 217 (01) : 236 - 239
  • [47] Three-dimensional versus two-dimensional ultrasonographic assessment of peripheral enthesitis in spondylarthritis
    Merot, Oriane
    Guillot, Pascale
    Maugars, Yves
    Le Goff, Benoit
    [J]. CLINICAL RHEUMATOLOGY, 2014, 33 (01) : 131 - 135
  • [48] Three-Dimensional Structure from Single Two-Dimensional Diffraction Intensity Measurement
    Latychevskaia, Tatiana
    [J]. PHYSICAL REVIEW LETTERS, 2021, 127 (06)
  • [49] Accuracy of Three-Dimensional Versus Two-Dimensional Echocardiography for Quantification of Aortic Regurgitation and Validation by Three-Dimensional Three-Directional Velocity-Encoded Magnetic Resonance Imaging
    Ewe, See Hooi
    Delgado, Victoria
    van der Geest, Rob
    Westenberg, Jos J. M.
    Haeck, Marlieke L. A.
    Witkowski, Tomasz G.
    Auger, Dominique
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Sieders, Allard
    Siebelink, Hans-Marc J.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (04): : 560 - 566
  • [50] Two-Dimensional Imaging of a Complex Three-Dimensional Structure: Measurements of Aortic Root Dimensions
    Tretter, Justin T.
    Mori, Shumpei
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (06) : 792 - 794