In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI

被引:2
|
作者
Rengier, Fabian [1 ,2 ]
Delles, Michael [3 ]
Unterhinninghofen, Roland [3 ]
Ley, Sebastian [1 ]
Mueller-Eschner, Matthias [1 ,2 ]
Partovi, Sasan [1 ]
Geisbuesch, Philipp [4 ]
Dillmann, Ruediger [3 ]
Kauczor, Hans-Ulrich [1 ]
von Tengg-Kobligk, Hendrik [1 ,2 ]
机构
[1] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr DKFZ Heidelberg, Dept Radiol, D-69120 Heidelberg, Germany
[3] Karlsruhe Inst Technol KIT, Inst Anthropomat, Dept Informat, D-76131 Karlsruhe, Germany
[4] Univ Heidelberg Hosp, Dept Vasc & Endovasc Surg, D-69120 Heidelberg, Germany
来源
关键词
Magnetic resonance imaging; Blood flow velocity; Three-dimensional imaging; Cardiovascular diagnostic techniques; Aorta; CARDIOVASCULAR MAGNETIC-RESONANCE; PHASE-CONTRAST MRI; BLOOD-FLOW; HEALTHY-VOLUNTEERS; WHOLE HEART; 4D FLOW; ACCURACY; PATTERNS; STRESS; VISUALIZATION;
D O I
10.1007/s10554-012-0027-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional velocity-encoded cine magnetic resonance imaging (3D VEC MRI) allows for calculation of secondary flow parameters that may be used to estimate prognosis of individual cardiovascular diseases. However, its accuracy has not been fully investigated yet. The purpose of this study was to validate aortic flow quantification by 3D VEC MRI in vitro and in vivo using stacked two-dimensional acquisitions. Time-resolved stacks of two-dimensional planes with three-directional velocity-encoding (stacked-2D-3dir-MRI) were acquired in an elastic tube phantom with pulsatile flow simulating aortic flow as well as in 11 healthy volunteers (23 +/- 2 years). Previously validated two-dimensional through-plane VEC MRI at six equidistant levels in vitro and three locations in vivo (ascending aorta/aortic arch/descending aorta) was used as reference standard. The percentage difference of the stacked-2D-3dir-MRI measurement to the reference standard was defined as the parameter for accuracy. For in vitro aortic flow, stacked-2D-3dir-MRI underestimated average velocity by -6.8% (p < 0.001), overestimated average area by 13.6% (p < 0.001), and underestimated average flow by -7.4% (p < 0.001). Accuracy was significantly higher in the field of view centre compared to off-centre (p = 0.001). In vivo, stacked-2D-3dir-MRI underestimated average velocity (all three locations p < 0.001) and overestimated average area at all three locations (p = n.s./< 0.001/< 0.001). Average flow was significantly underestimated in the ascending aorta (p = 0.035), but tended to be overestimated in the aortic arch and descending aorta. In conclusion, stacked-2D-3dir-MRI tends to overestimate average aortic area and to underestimate average aortic velocity, resulting in significant underestimation of average flow in the ascending aorta.
引用
收藏
页码:1999 / 2008
页数:10
相关论文
共 50 条
  • [1] In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI
    Fabian Rengier
    Michael Delles
    Roland Unterhinninghofen
    Sebastian Ley
    Matthias Müller-Eschner
    Sasan Partovi
    Philipp Geisbüsch
    Rüdiger Dillmann
    Hans-Ulrich Kauczor
    Hendrik von Tengg-Kobligk
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1999 - 2008
  • [2] Impact of an Aortic Nitinol Stent Graft on Flow Measurements by Time-resolved Three-dimensional Velocity-encoded MRI
    Rengier, Fabian
    Delles, Michael
    Unterhinninghofen, Roland
    Ley, Sebastian
    Partovi, Sasan
    Dillmann, Ruediger
    Kauczor, Hans-Ulrich
    von Tengg-Kobligk, Hendrik
    [J]. ACADEMIC RADIOLOGY, 2012, 19 (03) : 274 - 280
  • [3] In vitro validation of flow measurements in an aortic nitinol stent graft by velocity-encoded MRI
    Rengier, Fabian
    Delles, Michael
    Weber, Tim Frederik
    Boeckler, Dittmar
    Ley, Sebastian
    Kauczor, Hans-Ulrich
    von Tengg-Kobligk, Hendrik
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) : 163 - 167
  • [4] Multi-Dimensional Flow-Preserving Compressed Sensing (MuFloCoS) for Time-Resolved Velocity-Encoded Phase Contrast MRI
    Hutter, Jana
    Schmitt, Peter
    Saake, Marc
    Stuebinger, Axel
    Grimm, Robert
    Forman, Christoph
    Greiser, Andreas
    Hornegger, Joachim
    Maier, Andreas
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 400 - 432
  • [5] Accuracy of Three-Dimensional Versus Two-Dimensional Echocardiography for Quantification of Aortic Regurgitation and Validation by Three-Dimensional Three-Directional Velocity-Encoded Magnetic Resonance Imaging
    Ewe, See Hooi
    Delgado, Victoria
    van der Geest, Rob
    Westenberg, Jos J. M.
    Haeck, Marlieke L. A.
    Witkowski, Tomasz G.
    Auger, Dominique
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Sieders, Allard
    Siebelink, Hans-Marc J.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (04): : 560 - 566
  • [6] Validation and Reproducibility of Aortic Pulse Wave Velocity as Assessed With Velocity-Encoded MRI
    Grotenhuis, Heynric B.
    Westenberg, Jos M.
    Steendijk, Paul
    van der Geest, Rob J.
    Ottenkamp, Jaap
    Bax, Jeroen J.
    Jukema, J. Wouter
    de Roos, Albert
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 521 - 526
  • [7] Faster flow quantification using sensitivity encoding for velocity-encoded cine magnetic resonance imaging: In vitro and in vivo validation
    Prakash, Ashwin
    Garg, Ruchira
    Marcus, Edward N.
    Reynolds, Glenn
    Geva, Tal
    Powell, Andrew J.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 676 - 682
  • [8] MULTI-DIMENSIONAL FLOW-ADAPTED COMPRESSED SENSING (MDFCS) FOR TIME-RESOLVED VELOCITY-ENCODED PHASE CONTRAST MRA
    Hutter, Jana
    Grimm, Robert
    Forman, Christoph
    Greiser, Andreas
    Hornegger, Joachim
    Schmitt, Peter
    [J]. 2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 13 - 16
  • [9] 154 Aortic pulse wave velocity assessed with velocity-encoded MRI: a validation and reproducibility study
    Heynric B Grotenhuis
    Jos JM Westenberg
    Paul Steendijk
    Theodorus AM Kaandorp
    Wouter J Jukema
    Jeroen J Bax
    Johan HC Reiber
    Albert de Roos
    [J]. Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [10] In vivo validation of flow volume measurements through nitinol stents using velocity-encoded cine MRI
    Kuehne, T
    Saeed, M
    Reddy, GP
    Akbari, H
    Moore, P
    Higgins, CB
    [J]. RADIOLOGY, 2001, 221 : 598 - 599