In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI

被引:2
|
作者
Rengier, Fabian [1 ,2 ]
Delles, Michael [3 ]
Unterhinninghofen, Roland [3 ]
Ley, Sebastian [1 ]
Mueller-Eschner, Matthias [1 ,2 ]
Partovi, Sasan [1 ]
Geisbuesch, Philipp [4 ]
Dillmann, Ruediger [3 ]
Kauczor, Hans-Ulrich [1 ]
von Tengg-Kobligk, Hendrik [1 ,2 ]
机构
[1] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr DKFZ Heidelberg, Dept Radiol, D-69120 Heidelberg, Germany
[3] Karlsruhe Inst Technol KIT, Inst Anthropomat, Dept Informat, D-76131 Karlsruhe, Germany
[4] Univ Heidelberg Hosp, Dept Vasc & Endovasc Surg, D-69120 Heidelberg, Germany
来源
关键词
Magnetic resonance imaging; Blood flow velocity; Three-dimensional imaging; Cardiovascular diagnostic techniques; Aorta; CARDIOVASCULAR MAGNETIC-RESONANCE; PHASE-CONTRAST MRI; BLOOD-FLOW; HEALTHY-VOLUNTEERS; WHOLE HEART; 4D FLOW; ACCURACY; PATTERNS; STRESS; VISUALIZATION;
D O I
10.1007/s10554-012-0027-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional velocity-encoded cine magnetic resonance imaging (3D VEC MRI) allows for calculation of secondary flow parameters that may be used to estimate prognosis of individual cardiovascular diseases. However, its accuracy has not been fully investigated yet. The purpose of this study was to validate aortic flow quantification by 3D VEC MRI in vitro and in vivo using stacked two-dimensional acquisitions. Time-resolved stacks of two-dimensional planes with three-directional velocity-encoding (stacked-2D-3dir-MRI) were acquired in an elastic tube phantom with pulsatile flow simulating aortic flow as well as in 11 healthy volunteers (23 +/- 2 years). Previously validated two-dimensional through-plane VEC MRI at six equidistant levels in vitro and three locations in vivo (ascending aorta/aortic arch/descending aorta) was used as reference standard. The percentage difference of the stacked-2D-3dir-MRI measurement to the reference standard was defined as the parameter for accuracy. For in vitro aortic flow, stacked-2D-3dir-MRI underestimated average velocity by -6.8% (p < 0.001), overestimated average area by 13.6% (p < 0.001), and underestimated average flow by -7.4% (p < 0.001). Accuracy was significantly higher in the field of view centre compared to off-centre (p = 0.001). In vivo, stacked-2D-3dir-MRI underestimated average velocity (all three locations p < 0.001) and overestimated average area at all three locations (p = n.s./< 0.001/< 0.001). Average flow was significantly underestimated in the ascending aorta (p = 0.035), but tended to be overestimated in the aortic arch and descending aorta. In conclusion, stacked-2D-3dir-MRI tends to overestimate average aortic area and to underestimate average aortic velocity, resulting in significant underestimation of average flow in the ascending aorta.
引用
收藏
页码:1999 / 2008
页数:10
相关论文
共 50 条
  • [21] Flow quantification from time-resolved MRI vector fields
    Unterhinninghofen, R
    Albers, J
    Hosch, W
    Vahl, C
    Dillmann, R
    [J]. CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 126 - 130
  • [22] Accuracy of Sparse Temporal and Spatial Aortic Pulse Wave Velocity Sampling with Velocity-Encoded MRI: Validation in Patients with Marfan Syndrome
    Kroner, Eleanore S.
    van der Geest, Rob
    Scholte, Arthur
    Lamb, Hildo
    Siebelink, Hans-Marc
    Mulder, Barbara
    Van der Wall, Ernst
    de Roos, Albert
    Reiber, Johan
    Westenberg, Jos
    [J]. CIRCULATION, 2011, 124 (21)
  • [23] A method for three-dimensional time-resolved optical tomography
    Arridge, SR
    Hebden, JC
    Schwinger, M
    Schmidt, FEW
    Fry, ME
    Hillman, EMC
    Dehghani, H
    Delpy, DT
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2000, 11 (01) : 2 - 11
  • [24] Three-dimensional, time-resolved motion of the coronary arteries
    Johnson, KR
    Patel, SJ
    Whigham, A
    Hakim, A
    Pettigrew, RI
    Oshinski, JN
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (03) : 663 - 673
  • [25] Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation
    Markl, Michael
    Geiger, Julia
    Kilner, Philip J.
    Foell, Daniela
    Stiller, Brigitte
    Beyersdorf, Friedhelm
    Arnold, Raoul
    Frydrychowicz, Alex
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (02) : 206 - 212
  • [26] Velocity mapping of the aortic flow at 9.4 T in healthy mice and mice with induced heart failure using time-resolved three-dimensional phase-contrast MRI (4D PC MRI)
    Philipp Rene Bovenkamp
    Tobias Brix
    Florian Lindemann
    Richard Holtmeier
    Desiree Abdurrachim
    Michael T. Kuhlmann
    Gustav J. Strijkers
    Jörg Stypmann
    Klaus H. Hinrichs
    Verena Hoerr
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 315 - 327
  • [27] Velocity mapping of the aortic flow at 9.4 T in healthy mice and mice with induced heart failure using time-resolved three-dimensional phase-contrast MRI (4D PC MRI)
    Bovenkamp, Philipp Rene
    Brix, Tobias
    Lindemann, Florian
    Holtmeier, Richard
    Abdurrachim, Desiree
    Kuhlmann, Michael T.
    Strijkers, Gustav J.
    Stypmann, Joerg
    Hinrichs, Klaus H.
    Hoerr, Verena
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (04) : 315 - 327
  • [28] Imaging of the Thoracic Aorta with Time-Resolved Three-Dimensional Phase-Contrast MRI: A Review
    Hope, Thomas A.
    Herfkens, Robert J.
    [J]. SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2008, 20 (04) : 358 - 364
  • [29] Estimation of relative cardiovascular pressures using time-resolved three-dimensional phase contrast MRI
    Ebbers, T
    Wigström, L
    Bolger, AF
    Engvall, J
    Karlsson, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 872 - 879
  • [30] Time-resolved imaging of three-dimensional nanoscale magnetization dynamics
    Donnelly, Claire
    Finizio, Simone
    Gliga, Sebastian
    Holler, Mirko
    Hrabec, Ales
    Odstrcil, Michal
    Mayr, Sina
    Scagnoli, Valerio
    Heyderman, Laura J.
    Guizar-Sicairos, Manuel
    Raabe, Joerg
    [J]. NATURE NANOTECHNOLOGY, 2020, 15 (05) : 356 - +