Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs

被引:38
|
作者
Lund, GK
Wendland, MF
Shimakawa, A
Arheden, H
Ståhlberg, F
Higgins, CB
Saeed, M
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[3] Univ Lund Hosp, Dept Radiat Phys, S-22185 Lund, Sweden
[4] GE Med Syst, Milwaukee, WI USA
关键词
coronary vessels; flow dynamics; MR; stenosis or obstruction; magnetic resonance (MR); cine studies; experimental studies; vascular studies; myocardium. blood supply;
D O I
10.1148/radiology.217.2.r00nv10487
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To validate coronary sinus flow measurements for quantification of global left ventricular (LV) perfusion by means of velocity-encoded cine (VEC) magnetic resonance (MR) imaging and flow probes. MATERIALS AND METHODS: Measurements of coronary sinus flow were performed in seven dogs by using VEC MR imaging at baseline, single coronary arterial stenosis, dipyridamole stress, and reactive hyperemia. These measurements were compared with flow probe measurements of coronary blood flow (CBF) in the left anterior descending coronary (LAD) and circumflex (CFX) arteries (CBFLAD+CFX) and coronary sinus. LV blood perfusion was calculated in milliliters per minute per gram from coronary sinus flow, and LV mass was obtained by using VEC and cine MR imaging. LV mass was validated at autopsy. RESULTS: CBFLAD+CFX and coronary sinus flow at VEC MR imaging showed close correlation (r = 0.98, P < .001). The difference between CBFLAD+CFX and MR coronary sinus flow was 3.1 mL/min +/- 8.5 (SD). LV mass at cine MR imaging was not significantly different from that at autopsy (73.2 g +/- 12.8 vs 69.4 g +/- 12.8). At baseline, myocardial perfusion was 0.40 mL/min/g +/- 0.09 at VEC MR imaging, and CBFLAD+CFX was 0.44 ml/min/g +/- 0.08 (not significant). Reactive hyperemia resulted in 2.7- and 2.3-fold increases in coronary sinus flow at VEC MR imaging and flow probe CBFLAD+CFX respectively. CONCLUSION: VEC MR imaging has the potential to measure coronary sinus flow during different physiologic conditions and can serve as a noninvasive modality to quantify global LV perfusion in patients.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [31] SEVERITY OF AORTIC REGURGITATION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH VELOCITY-ENCODED CINE MR-IMAGING
    DULCE, MC
    MOSTBECK, GH
    OSULLIVAN, M
    CHEITLIN, M
    CAPUTO, GR
    HIGGINS, CB
    RADIOLOGY, 1992, 185 (01) : 235 - 240
  • [32] Measurement of coronary flow response to cold pressor stress in asymptomatic women with cardiovascular risk factors using spiral velocity-encoded cine MRI at 3 Tesla
    Maroules, Christopher D.
    Chang, Alice Y.
    Kontak, Andrew
    Dimitrov, Ivan
    Kotys, Melanie
    Peshock, Ronald M.
    ACTA RADIOLOGICA, 2010, 51 (04) : 420 - 426
  • [33] Arterial, Venous, and Cerebrospinal Fluid Flow: Simultaneous Assessment with Bayesian Multipoint Velocity-encoded MR Imaging
    Knobloch, Verena
    Binter, Christian
    Kurtcuoglu, Vartan
    Kozerke, Sebastian
    RADIOLOGY, 2014, 270 (02) : 566 - 573
  • [34] Measurement of coronary flow reserve with fast cine phase-contrast MR imaging: Validation study with Doppler flow wire in humans
    Sakuma, H
    Shibata, M
    Takeda, K
    Nakagawa, T
    Nakano, T
    Higgins, CB
    RADIOLOGY, 1996, 201 : 1248 - 1248
  • [35] MR assessment of coronary flow reserve: Validation study by measuring volume flow rate in the coronary sinus and peak flow velocity in the coronary artery
    Sakuma, H
    Kawada, N
    Takeda, K
    Yamakado, T
    Nakano, T
    RADIOLOGY, 1997, 205 : 480 - 480
  • [36] Automated vessel edge detection in velocity-encoded cine-MR (VEC-MR) flow measurements: a retrospective evaluation in critically ill patients
    Henk, CB
    Grampp, S
    Backfrieder, W
    Liskutin, J
    Czerny, C
    Mostbeck, GH
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) : 274 - 281
  • [37] Manual versus automated vessel edge detection, intra- and interobserver variability in velocity-encoded cine-MR flow measurements
    Henk, CB
    Backfrieder, W
    Liskutin, J
    Kouwenhoven, M
    vanderGeest, RJ
    Reiber, RHC
    Mostbeck, GH
    CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 85 - 87
  • [38] ASSESSMENT OF BLOOD-FLOW IN HEMODIALYSIS SHUNTS AND HIGH-OUTPUT CARDIAC-FAILURE IN RENAL-ALLOGRAFT RECIPIENTS BY USING VELOCITY-ENCODED CINE MR-IMAGING
    HENK, CB
    DEICHER, R
    TURETSCHEK, K
    DERFLER, K
    IMHOF, H
    MOSTBECK, GH
    RADIOLOGY, 1995, 197 : 422 - 422
  • [39] ASSESSMENT OF CORONARY FLOW RESERVE IN MAN WITH BREATH-HOLD VELOCITY-ENCODED MAGNETIC-RESONANCE-IMAGING
    SAKUMA, H
    BLAKE, LM
    AMIDON, TM
    OSULLIVAN, M
    SZOLAR, DH
    GLOBITS, S
    FURBER, AP
    BERNSTEIN, MA
    FOO, TK
    HIGGINS, CB
    CIRCULATION, 1995, 92 (08) : 1496 - 1496
  • [40] In vitro validation of flow measurements in an aortic nitinol stent graft by velocity-encoded MRI
    Rengier, Fabian
    Delles, Michael
    Weber, Tim Frederik
    Boeckler, Dittmar
    Ley, Sebastian
    Kauczor, Hans-Ulrich
    von Tengg-Kobligk, Hendrik
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) : 163 - 167