Cuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time

被引:61
|
作者
Yoon, Young-Zoon [1 ]
Kang, Jae Min [1 ]
Kwon, Yongjoo [1 ]
Park, Sangyun [1 ]
Noh, Seungwoo [1 ]
Kim, Younho [1 ]
Park, Jongae [1 ]
Hwang, Sung Woo [1 ]
机构
[1] Samsung Adv Inst Technol, Suwon 16678, South Korea
关键词
Cuff-less blood pressure measurement; photoplethysmography; pulse arrival time; pulse waveform analysis; wearable device; TRANSIT-TIME; NONINVASIVE ESTIMATION; VELOCITY; EXERCISE; SIGNALS; MARKER; ECG; PPG;
D O I
10.1109/JBHI.2017.2714674
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Using the massive MIMIC physiological data base, we tried to validate pulse wave analysis (PWA) based on multiparameters model whether it can continuously estimate blood pressure (BP) values on single site of one hand. In addition, to consider the limitation of insufficient data acquirement for home user, we used pulse arrival time (PAT) driven BP information to determine the individual scale factors of the PWA-BP estimation model. Experimental results indicate that the accuracy of the average regression model has error standard deviations of 10.6 +/- 3.3 mmHg (PAT), 8.7 +/- 3.2 mmHg (PWA) for SBP and 6.0 +/- 2.3 mmHg (PAT), 4.4 +/- 1.6 mmHg (PWA) for DBP on 23 subjects over a 1 day period. We defined a local-model which is extracted regression model from sparsely selected small dataset, contrast to full dataset for 24h (average-model). The limit of BP estimation accuracy from the local-model of PWA is lower than that of PAT-BP average-model. Whereas the error of the BP estimation local-model was reduced using more data for scaling, it required more than four times the 1 min data extracted over the 12 h calibration period to predict BP for 1 day. This study shows that PWA has possibility to estimate BP value and PAT-driven BP information could be used to determine the individual scale factors of the PWA-BP estimation model for home users.
引用
收藏
页码:1068 / 1074
页数:7
相关论文
共 50 条
  • [31] Cuff-less Blood Pressure Estimation Using Hetero-core Optical Fibers
    Koyama Y.
    Kamada H.
    Watanabe K.
    Nishiyama M.
    IEEJ Transactions on Sensors and Micromachines, 2023, 143 (11) : 365 - 372
  • [32] KD-Informer: A Cuff-Less Continuous Blood Pressure Waveform Estimation Approach Based on Single Photoplethysmography
    Ma, Chenbin
    Zhang, Peng
    Song, Fan
    Sun, Yangyang
    Fan, Guangda
    Zhang, Tianyi
    Feng, Youdan
    Zhang, Guanglei
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (05) : 2219 - 2230
  • [33] Cuff-Less Methods for Blood Pressure Measurement
    Gan, Liangzhi
    Wang, Chen
    Liu, Haikuan
    Zhang, Lei
    2019 CHINESE AUTOMATION CONGRESS (CAC2019), 2019, : 4926 - 4930
  • [34] Cuff-Less Blood Pressure Monitoring System Using Smartphones
    Tabei, Fatemehsadat
    Gresham, Jon Michael
    Askarian, Behnam
    Jung, Kwanghee
    Chong, Jo Woon
    IEEE ACCESS, 2020, 8 : 11534 - 11545
  • [35] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Li-Ping Yao
    Zhong-liang Pan
    Physical and Engineering Sciences in Medicine, 2021, 44 : 397 - 408
  • [36] Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    W. Chen
    T. Kobayashi
    S. Ichikawa
    Y. Takeuchi
    T. Togawa
    Medical and Biological Engineering and Computing, 2000, 38 : 569 - 574
  • [37] Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors
    Baek, Hyun Jae
    Kim, Ko Keun
    Kim, Jung Soo
    Lee, Boreom
    Park, Kwang Suk
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (02) : 145 - 157
  • [38] Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    Chen, W
    Kobayashi, T
    Ichikawa, S
    Takeuchi, Y
    Togawa, T
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) : 569 - 574
  • [39] Pulse Arrival Time and Ballistocardiogram Application to Blood Pressure Variability Estimation
    Pinheiro, Eduardo
    Postolache, Octavian
    Girao, Pedro
    MEMEA: 2009 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2009, : 132 - +
  • [40] Evaluation of blood pressure estimation models based on pulse arrival time
    Bote, Jose M.
    Recas, Joaquin
    Hermida, Roman
    COMPUTERS & ELECTRICAL ENGINEERING, 2020, 84