Cuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time

被引:61
|
作者
Yoon, Young-Zoon [1 ]
Kang, Jae Min [1 ]
Kwon, Yongjoo [1 ]
Park, Sangyun [1 ]
Noh, Seungwoo [1 ]
Kim, Younho [1 ]
Park, Jongae [1 ]
Hwang, Sung Woo [1 ]
机构
[1] Samsung Adv Inst Technol, Suwon 16678, South Korea
关键词
Cuff-less blood pressure measurement; photoplethysmography; pulse arrival time; pulse waveform analysis; wearable device; TRANSIT-TIME; NONINVASIVE ESTIMATION; VELOCITY; EXERCISE; SIGNALS; MARKER; ECG; PPG;
D O I
10.1109/JBHI.2017.2714674
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Using the massive MIMIC physiological data base, we tried to validate pulse wave analysis (PWA) based on multiparameters model whether it can continuously estimate blood pressure (BP) values on single site of one hand. In addition, to consider the limitation of insufficient data acquirement for home user, we used pulse arrival time (PAT) driven BP information to determine the individual scale factors of the PWA-BP estimation model. Experimental results indicate that the accuracy of the average regression model has error standard deviations of 10.6 +/- 3.3 mmHg (PAT), 8.7 +/- 3.2 mmHg (PWA) for SBP and 6.0 +/- 2.3 mmHg (PAT), 4.4 +/- 1.6 mmHg (PWA) for DBP on 23 subjects over a 1 day period. We defined a local-model which is extracted regression model from sparsely selected small dataset, contrast to full dataset for 24h (average-model). The limit of BP estimation accuracy from the local-model of PWA is lower than that of PAT-BP average-model. Whereas the error of the BP estimation local-model was reduced using more data for scaling, it required more than four times the 1 min data extracted over the 12 h calibration period to predict BP for 1 day. This study shows that PWA has possibility to estimate BP value and PAT-driven BP information could be used to determine the individual scale factors of the PWA-BP estimation model for home users.
引用
收藏
页码:1068 / 1074
页数:7
相关论文
共 50 条
  • [21] Cuff-less Blood Pressure Estimation Using Kalman Filter on Android Platform
    He, Zhengling
    Chen, Xianxiang
    Fang, Zhen
    Tang, Minfang
    Li, Junxia
    Xia, Shanhong
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), 2017,
  • [22] Improving Cuff-Less Continuous Blood Pressure Estimation with Linear Regression Analysis
    Figini, Valeria
    Galici, Sofia
    Russo, Daniele
    Centonze, Ilenia
    Visintin, Monica
    Pagana, Guido
    ELECTRONICS, 2022, 11 (09)
  • [23] Cuff-less wearable biosensor in continuous noninvasive human radial artery pulse waveform and blood pressure measurement using self-mixing interferometry
    Zhao, Yu
    Yao, Xijie
    Hu, Jinguo
    Zhang, Zihua
    Chen, Tao
    OPTICS EXPRESS, 2024, 32 (24): : 42213 - 42224
  • [24] Effect of confounding factors on blood pressure estimation using pulse arrival time
    Kim, Jung Soo
    Kim, Ko Keun
    Baek, Hyun Jae
    Park, Kwang Suk
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (05) : 615 - 624
  • [25] A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
    Polinski, Artur
    Pietrewicz, Michal
    Kocejko, Tomasz
    Bujnowski, Adam
    Ruminski, Jacek
    Wtorek, Jerzy
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5822 - 5825
  • [26] A Novel Indicator for Cuff-Less Blood Pressure Estimation Based on Photoplethysmography
    Jiang, Hongyang
    Miao, Fen
    Gao, Mengdi
    Hong, Xi
    He, Qingyun
    Ma, He
    Li, Ye
    HEALTH INFORMATION SCIENCE, HIS 2016, 2016, 10038 : 119 - 128
  • [27] Cuff-less blood pressure estimation using hetero-core optical fibers
    Koyama, Yuya
    Kamada, Hiroki
    Watanabe, Kazuhiro
    Nishiyama, Michiko
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2024, 107 (01)
  • [28] Cuff-Less Blood Pressure Estimation Using Only the ECG Signal in Frequency Domain
    Mousavi, Seyedeh Somayyeh
    Hemmati, Mohammad
    Charmi, Mostafa
    Moghadam, Maryam
    Firouzmand, Mohammad
    Ghorbani, Yadollah
    2018 8TH INTERNATIONAL CONFERENCE ON COMPUTER AND KNOWLEDGE ENGINEERING (ICCKE), 2018, : 147 - 152
  • [29] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Yao, Li-Ping
    Pan, Zhong-liang
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 397 - 408
  • [30] Estimation of central blood pressure using radial pulse waveform
    Wei, Ran
    Im, Jae Joong
    Park, Sung Ha
    Jung, Nam Sik
    2007 INTERNATIONAL SYMPOSIUM ON INFORMATION TECHNOLOGY CONVERGENCE, PROCEEDINGS, 2007, : 250 - +