Cuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time

被引:61
|
作者
Yoon, Young-Zoon [1 ]
Kang, Jae Min [1 ]
Kwon, Yongjoo [1 ]
Park, Sangyun [1 ]
Noh, Seungwoo [1 ]
Kim, Younho [1 ]
Park, Jongae [1 ]
Hwang, Sung Woo [1 ]
机构
[1] Samsung Adv Inst Technol, Suwon 16678, South Korea
关键词
Cuff-less blood pressure measurement; photoplethysmography; pulse arrival time; pulse waveform analysis; wearable device; TRANSIT-TIME; NONINVASIVE ESTIMATION; VELOCITY; EXERCISE; SIGNALS; MARKER; ECG; PPG;
D O I
10.1109/JBHI.2017.2714674
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Using the massive MIMIC physiological data base, we tried to validate pulse wave analysis (PWA) based on multiparameters model whether it can continuously estimate blood pressure (BP) values on single site of one hand. In addition, to consider the limitation of insufficient data acquirement for home user, we used pulse arrival time (PAT) driven BP information to determine the individual scale factors of the PWA-BP estimation model. Experimental results indicate that the accuracy of the average regression model has error standard deviations of 10.6 +/- 3.3 mmHg (PAT), 8.7 +/- 3.2 mmHg (PWA) for SBP and 6.0 +/- 2.3 mmHg (PAT), 4.4 +/- 1.6 mmHg (PWA) for DBP on 23 subjects over a 1 day period. We defined a local-model which is extracted regression model from sparsely selected small dataset, contrast to full dataset for 24h (average-model). The limit of BP estimation accuracy from the local-model of PWA is lower than that of PAT-BP average-model. Whereas the error of the BP estimation local-model was reduced using more data for scaling, it required more than four times the 1 min data extracted over the 12 h calibration period to predict BP for 1 day. This study shows that PWA has possibility to estimate BP value and PAT-driven BP information could be used to determine the individual scale factors of the PWA-BP estimation model for home users.
引用
收藏
页码:1068 / 1074
页数:7
相关论文
共 50 条
  • [1] Cuff-less blood pressure measurement using pulse arrival time and a Kalman filter
    Zhang, Qiang
    Chen, Xianxiang
    Fang, Zhen
    Xue, Yongjiao
    Zhan, Qingyuan
    Yang, Ting
    Xia, Shanhong
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2017, 27 (02)
  • [2] Effects of Pulse Transit Time and Pulse Arrival Time on Cuff-less Blood Pressure Estimation: A Comparison Study with Multiple Experimental Interventions
    Xie, Chenjie
    Wan, Cheng
    Wang, Yishan
    Song, Jinzhong
    Wu, Dan
    Li, Ye
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [3] Introduction of Boosting Algorithms in Continuous Non-Invasive Cuff-less Blood Pressure Estimation using Pulse Arrival Time
    Ghosh, Aayushman
    Chatterjee, Tamaghno
    Sarkar, Sayan
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5429 - 5432
  • [4] EDifferential Pulse Arrival Time: A Novel Approach to Continuous Cuff-less Blood Pressure Monitoring
    Pandit, Jay A.
    Miller, Kyle
    Wu, Jung-en
    Connell, Sean D.
    Shah, Sanjiv
    CIRCULATION, 2016, 134
  • [5] Differential Pulse Arrival Time: A Novel Approach to Continuous Cuff-less Blood Pressure Monitoring
    Pandit, Jay A.
    Miller, Kyle
    Wu, Jung-en
    Connell, Sean D.
    Shah, Sanjiv
    CIRCULATION, 2016, 134
  • [6] Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time
    Ganti, Venu G.
    Carek, Andrew M.
    Nevius, Brandi N.
    Heller, J. Alex
    Etemadi, Mozziyar
    Inan, Omer T.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 1926 - 1937
  • [7] Continuous Cuff-less Blood Pressure Monitoring based on the Pulse Arrival Time Approach: The Impact of Posture
    Muehlsteff, J.
    Aubert, X. A.
    Morren, G.
    2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 1691 - 1694
  • [8] Cuff-Less Continuous Blood Pressure Monitoring System Using Pulse Transit Time Techniques
    Zaki, Wan Suhaimizan Wan
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2016, 8 (01): : 51 - 57
  • [9] Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time
    Poon, C. C. Y.
    Zhang, Y. T.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5877 - 5880
  • [10] Cuff-Less High-Accuracy Calibration-Free Blood Pressure Estimation Using Pulse Transit Time
    Kachuee, Mohamad
    Kiani, Mohammad Mahdi
    Mohammadzade, Hoda
    Shabany, Mahdi
    2015 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2015, : 1006 - 1009