A comparison of the performance tests used for furniture packaging

被引:0
|
作者
Connolly, SM [1 ]
Marcondes, JA
Weigel, TG
Lee, A
机构
[1] Clemson Univ, Dept Packaging Sci, Clemson, SC 29634 USA
[2] Clemson Univ, Dept Forest Resources, Clemson, SC 29631 USA
关键词
furniture packaging; compression strength; performance tests; corrugated containers; distribution;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
ISTA Procedure 2C and two options in NMFCC Item 181, stacked vibration and compression and vibration in separate tests, were compared to determine the equivalency of common U.S furniture packaging performance tests. Containers constructed of two different corrugated fiberboard specifications were evaluated; Box A: a 32 lb/in. (5.6 kN/m) ECT rated board with a basis weight combination of 35HP/26/35HP, and Box B: a 200 psi (1378.95 kPa) Mullen rated board with a basis weight combination of 42/26/42. Ten corrugated fiberboard containers of each board type were tested following each of the test protocols. After testing, the contents were removed and the residual compression force at failure and deflection at failure of the containers were measured. These data were compared to the compression force and deflection at failure of control samples for the two board grades tested. Results showed that Item 181 Method A produced significantly different residual compression force at failure when compared to Item 181 Method B and Procedure 2C for both boxes. Item 181 Method B and Procedure 2C were not significantly different. Also, the two boxes showed significantly different residual compression force at failure results for each of the test protocols studied. The percent change in compression force at failure based on control samples, however, was not significantly different between the boxes studied.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [41] A COMPARISON BETWEEN COAGULATION TESTS USED FOR THE DETECTION OF LUPUS ANTICOAGULANT
    FORASTIERO, RR
    CERRATO, GS
    FALCON, CR
    CARRERAS, LO
    THROMBOSIS AND HAEMOSTASIS, 1989, 62 (01) : 379 - 379
  • [42] FURNITURE PERFORMANCE TESTING
    BELL, FA
    QUALITY PROGRESS, 1983, 16 (06) : 26 - 29
  • [43] Performance Tests of a Stereotactic Gamma Imaging System Used for Localization
    Welch, Benjamin L.
    Banks, David
    St Saviour, Torre
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3167 - +
  • [44] VARIATION IN FOOD MICROBIOLOGICAL TESTS USED TO EVALUATE ANALYST PERFORMANCE
    PEELER, JT
    MESSER, JW
    LESLIE, JE
    HOUGHTBY, GA
    JOURNAL OF FOOD PROTECTION, 1980, 43 (09) : 729 - 732
  • [45] Textiles used for balistic protection, their properties and balistic performance tests
    Bozdoğan, Faruk
    Üngün, Sacide
    Temel, Emrah
    Süpüren Mengüç, Gamze
    Tekstil ve Muhendis, 2015, 22 (98): : 84 - 103
  • [46] Performance of serologic tests used to detect heartworm infection in cats
    Snyder, PS
    Levy, JK
    Salute, ME
    Gorman, SP
    Kubilis, PS
    Smail, PW
    George, LL
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2000, 216 (05) : 693 - 700
  • [47] COMPARISON OF CHILDRENS PERFORMANCE ON 2 TESTS OF ARTICULATION
    SCHISSEL, RJ
    JAMES, LB
    JOURNAL OF SPEECH AND HEARING DISORDERS, 1979, 44 (03): : 363 - 372
  • [48] Performance comparison of VLV, ULV, and ECR tests
    Jiang, WL
    Peterson, E
    20TH IEEE VLSI TEST SYMPOSIUM, PROCEEDINGS, 2002, : 31 - 36
  • [49] Performance comparison of VLV, ULV, and ECR tests
    Jiang, WL
    Peterson, E
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2003, 19 (02): : 137 - 147
  • [50] Performance Comparison of VLV, ULV, and ECR Tests
    Wanli Jiang
    Eric Peterson
    Journal of Electronic Testing, 2003, 19 : 137 - 147