Performance comparison of VLV, ULV, and ECR tests

被引:4
|
作者
Jiang, WL [1 ]
Peterson, E [1 ]
机构
[1] Guidant Corp, Test Engn, St Paul, MN 55112 USA
关键词
very low voltage test; dynamic current test; test threshold; test effectiveness; test efficiency;
D O I
10.1023/A:1022881322125
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It has been shown that Very-Low-Voltage and Minimum-Voltage tests can detect defects that escape tests applied at normal voltages. Energy Consumption Ratio test, a recently developed current-based test, has shown its ability to reduce the impact of process variations and detect various types of defects. These tests may be used as supplements to traditional tests to ensure high quality product. In this paper, Very-Low-Voltage, Ultra-Low-Voltage (a modified version of Minimum-Voltage), and Energy Consumption Ratio tests are applied as supplemental tests along with existing traditional tests to a biomedical IC product. The effectiveness and efficiency of these supplemental tests are evaluated and compared with some major traditional tests. The effectiveness analysis indicates that Ultra-Low-Voltage and Energy Consumption Ratio tests identified potentially defective devices from the good devices. The efficiency analysis shows that Energy Consumption Ratio test is much more efficient than Very-Low-Voltage, Ultra-Low-Voltage, and major traditional tests.
引用
收藏
页码:137 / 147
页数:11
相关论文
共 50 条
  • [1] Performance Comparison of VLV, ULV, and ECR Tests
    Wanli Jiang
    Eric Peterson
    Journal of Electronic Testing, 2003, 19 : 137 - 147
  • [2] Performance comparison of VLV, ULV, and ECR tests
    Jiang, WL
    Peterson, E
    20TH IEEE VLSI TEST SYMPOSIUM, PROCEEDINGS, 2002, : 31 - 36
  • [3] HIGH-CURRENT ECR SOURCE FOR OXYGEN IMPLANTATION - LIFE TESTS AND COMPARISON TO DUOPIGATRON PERFORMANCE
    HIPPLE, J
    HAYDEN, C
    DIONNE, G
    TORII, Y
    SHIMADA, M
    WATANABE, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 294 - 296
  • [4] Effectiveness improvement of ECR tests
    Jiang, WL
    Peterson, E
    Robotka, B
    INTERNATIONAL TEST CONFERENCE 2003, PROCEEDINGS, 2003, : 699 - 708
  • [5] COMPARISON OF ULV WITH CONVENTIONAL SPRAYING ON COTTON IN PAKISTAN
    ATTIQUE, MR
    SHAKEEL, MA
    CROP PROTECTION, 1983, 2 (02) : 231 - 234
  • [6] DROPLETS IN AIR .2. CAPTURE BY NATURAL SURFACES - DEPOSITION AND DRIFT OF ULV AND VLV INSECTICIDE SPRAYS APPLIED TO COTTON BY HAND APPLICATOR IN NORTHERN NIGERIA
    JOHNSTONE, DR
    HUNTINGTON, KA
    PESTICIDE SCIENCE, 1977, 8 (01): : 101 - 109
  • [7] COMPARISON OF EC AND ULV FORMULATIONS ON HELIOTHIS IN COTTON IN AUSTRALIA
    DAVIES, RAH
    MERRETT, R
    MCLAREN, NA
    CAMERON, KJ
    OUTLOOK ON AGRICULTURE, 1982, 11 (03) : 123 - 126
  • [8] COMPARISON OF DIFFERENT TESTS OF FENCING PERFORMANCE
    HARMENBERG, J
    CECI, R
    BARVESTAD, P
    HJERPE, K
    NYSTROM, J
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1991, 12 (06) : 573 - 576
  • [9] CONTINUOUS PERFORMANCE TESTS - A COMPARISON OF MODALITIES
    BAKER, DB
    TAYLOR, CJ
    LEYVA, C
    JOURNAL OF CLINICAL PSYCHOLOGY, 1995, 51 (04) : 548 - 551
  • [10] EFFECT OF DROPLET SIZE ON PERSISTENCE OF ULV MALATHION AND COMPARISON OF TOXICITY OF ULV AND EC MALATHION TO TOBACCO BUDWORM LARVAE
    POLLES, SG
    VINSON, SB
    JOURNAL OF ECONOMIC ENTOMOLOGY, 1969, 62 (01) : 89 - &