A comparison of the performance tests used for furniture packaging

被引:0
|
作者
Connolly, SM [1 ]
Marcondes, JA
Weigel, TG
Lee, A
机构
[1] Clemson Univ, Dept Packaging Sci, Clemson, SC 29634 USA
[2] Clemson Univ, Dept Forest Resources, Clemson, SC 29631 USA
关键词
furniture packaging; compression strength; performance tests; corrugated containers; distribution;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
ISTA Procedure 2C and two options in NMFCC Item 181, stacked vibration and compression and vibration in separate tests, were compared to determine the equivalency of common U.S furniture packaging performance tests. Containers constructed of two different corrugated fiberboard specifications were evaluated; Box A: a 32 lb/in. (5.6 kN/m) ECT rated board with a basis weight combination of 35HP/26/35HP, and Box B: a 200 psi (1378.95 kPa) Mullen rated board with a basis weight combination of 42/26/42. Ten corrugated fiberboard containers of each board type were tested following each of the test protocols. After testing, the contents were removed and the residual compression force at failure and deflection at failure of the containers were measured. These data were compared to the compression force and deflection at failure of control samples for the two board grades tested. Results showed that Item 181 Method A produced significantly different residual compression force at failure when compared to Item 181 Method B and Procedure 2C for both boxes. Item 181 Method B and Procedure 2C were not significantly different. Also, the two boxes showed significantly different residual compression force at failure results for each of the test protocols studied. The percent change in compression force at failure based on control samples, however, was not significantly different between the boxes studied.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [31] Packaging performance comparison for distribution and export of papaya fruit
    Chonhenchob, V
    Singh, SP
    PACKAGING TECHNOLOGY AND SCIENCE, 2005, 18 (03) : 125 - 131
  • [32] Performance comparison of mesoscale refrigeration technologies for electronics packaging
    Phelan, PE
    Chiriac, V
    Lee, TYT
    ADVANCES IN ELECTRONIC PACKAGING 2003, VOL 2, 2003, : 309 - 315
  • [33] Organic PGA packaging - A performance comparison with ceramic PGA
    Viswanath, R
    Chiu, CP
    THIRTEENTH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 1997, 1997, : 119 - 130
  • [34] STANDARDIZED PACKAGING TESTS
    不详
    PACKAGING, 1984, 29 (04): : 330 - 333
  • [35] Research on Packaging Optimization in Customized Panel Furniture Enterprises
    Wang, Guokun
    Zhu, Jiangang
    Cai, Wenwen
    Liu, Bin
    Tian, Yubin
    Meng, Fanyang
    BIORESOURCES, 2021, 16 (01) : 1186 - 1206
  • [36] A COMPARISON OF CHEMICAL TESTS FOR OESTROGENS USED IN EQUINE PREGNANCY DIAGNOSIS
    COX, JE
    GALINA, CS
    VETERINARY RECORD, 1970, 86 (04) : 97 - +
  • [37] A COMPARISON OF PULMONARY-FUNCTION TESTS USED FOR BRONCHIAL CHALLENGES
    MICHOUD, MC
    GHEZZO, H
    AMYOT, R
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1982, 18 (04): : 609 - 621
  • [38] A COMPARISON OF STRESS TESTS USED TO EVALUATE THE ANTERIOR CRUCIATE LIGAMENT
    DRAPER, DO
    PHYSICIAN AND SPORTSMEDICINE, 1990, 18 (01): : 89 - &
  • [39] COMPARISON OF RAPID TESTS USED TO DETECT ANTIBIOTIC RESIDUES IN MILK
    SENYK, GF
    DAVIDSON, JH
    BROWN, JM
    HALLSTEAD, ER
    SHERBON, JW
    JOURNAL OF FOOD PROTECTION, 1990, 53 (02) : 158 - 164
  • [40] COMPARISON OF 4 INTELLIGENCE TESTS USED WITH CULTURALLY DISADVANTAGED CHILDREN
    JOHNSON, DL
    JOHNSON, CA
    PSYCHOLOGICAL REPORTS, 1971, 28 (01) : 209 - &