摘要
Point-of-care testing (POCT) coagulometers are increasingly being used in the hospital setting and patients' self-testing. We determined the agreement of prothrombin time international normalized ratio (INR) results by POCT coagulometer and laboratory instrument through a comparative analysis and investigated whether the results of POCT coagulometer can reliably be used without being confirmed by standard laboratory analyzer. A total of 200 INR measurements by POCT coagulometer (CoaguChek XS Pro) and laboratory analyzer (Sysmex CS2000i) were compared using Passing-Bablok regression analysis and Bland-Altman plot. Agreement of the INR measurement was further analyzed in relation to dosing decision. The correlation of INR measurements between CoaguChek XS Pro and Sysmex CS2000i was excellent (correlation coefficient = 0.973). The overall mean difference was 0.21 INR +/- 0.32 (range: 1.7-0.44). The mean difference was found to get increased as INR results increased and was 0.09 in the subtherapeutic range (1.9 INR), 0.29 INR in the therapeutic range (2.0-3.0 INR), while 0.4 INR in the supratherapeutic range (>3.0 INR). The overall agreement was excellent ( = 0.916) and overall 11 (5.5%) of 200 INR measurements showed a difference in dosing decision between the 2 instruments. The positive bias of POC-INR is evident in the supratherapeutic range which could affect the dosing decision requiring confirmation with the laboratory INR measurement.
引用
收藏
页码:1153 / 1158
页数:6
相关论文
共 50 条
  • [21] Comparison of the international normalized ratio (INR) between a point-of-care test and a reference Central laboratory method
    Sammartano, A.
    Buonocore, R.
    Magliani, M.
    Testa, G.
    Ippolito, L.
    CLINICA CHIMICA ACTA, 2024, 558
  • [22] International Normalized Ratio Point of Care Testing in an Outpatient Anticoagulation Clinic and the Impact on the Patient Experience: A Quality Improvement Study
    Chisholm, K.
    Culley, C.
    Spina, S.
    CANADIAN JOURNAL OF HOSPITAL PHARMACY, 2018, 71 (01): : 71 - 71
  • [23] International normalized ratio testing with point-of-care coagulometer in healthy term neonates
    Shigeo Iijima
    Toru Baba
    Daizo Ueno
    Akira Ohishi
    BMC Pediatrics, 14
  • [24] Reliability of Point-of-Care International Normalized Ratio Measurements in Various Patient Populations
    Arline, Kim
    Rodriguez, Cesar
    Sanchez, Krista
    POINT OF CARE, 2020, 19 (01): : 12 - 18
  • [25] Inaccuracy of Point-of-Care International Normalized Ratio in Rivaroxaban-Treated Patients
    Baruch, Lawrence
    Sherman, Olga
    ANNALS OF PHARMACOTHERAPY, 2013, 47 (09) : 1210 - 1212
  • [26] Accuracy and Precision of Point-of-Care International Normalized Ratio in Patients With Liver Disease
    Shadlyn, Tevyn
    Bauman, Mary
    Tandon, Puneeta
    Yap, Jason
    Kawada, Patricia
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2023, 76 (06): : 704 - 709
  • [27] International normalized ratio testing with point-of-care coagulometer in healthy term neonates
    Iijima, Shigeo
    Baba, Toru
    Ueno, Daizo
    Ohishi, Akira
    BMC PEDIATRICS, 2014, 14
  • [28] Validation of the Use of a Point-of-Care Device in Monitoring the International Normalised Ratio in Postoperative Cardiac Patients
    Wee, Hide E.
    Sin, Kenny Y. K.
    Chiang, Patsy
    Guo, Kenneth W. Q.
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2016, 45 (09) : 424 - 426
  • [29] Point of care monitoring of oral anticoagulant therapy in children:: comparison of CoaguChek Plus and Thrombotest methods with venous international normalised ratio
    Ignjatovic, V
    Barnes, C
    Newall, F
    Hamilton, S
    Burgess, J
    Monagle, P
    THROMBOSIS AND HAEMOSTASIS, 2004, 92 (04) : 734 - 737
  • [30] A Comprehensive Clinical Assessment of the LumiraDx International Normalized Ratio (INR) Assay for Point-of-Care Monitoring in Anticoagulation Therapy
    Munir, Riffat
    Schapkaitz, Elise
    Noble, Lara
    Loonat, Sakina
    Mccree, Melanie
    Ali, Nazeer
    Jacobson, Barry
    Stevens, Wendy Susan
    Scott, Lesley Erica
    DIAGNOSTICS, 2024, 14 (23)