Reliability of Point-of-Care International Normalized Ratio Measurements in Various Patient Populations

被引:3
|
作者
Arline, Kim [1 ]
Rodriguez, Cesar [1 ]
Sanchez, Krista [1 ]
机构
[1] Parkview Med Ctr, Pueblo, CO USA
来源
POINT OF CARE | 2020年 / 19卷 / 01期
关键词
anticoagulation; international normalized ratio reliability; point-of-care; Coagsense; Coagucheck XS; Stago; warfarin; antiphospholipid syndrome; Hypercoagulable disorders; LUPUS ANTICOAGULANT; INR; DEVICES; SYSTEM;
D O I
10.1097/POC.0000000000000197
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Purpose: The aim of this study was to determine if the Coagsense point-of-care (POC) instrument provides more reliable international normalized ratio (INR) measurements than Coagucheck XS POC in comparison to the Stago laboratory instrument in different disease states. Methods: This was a prospective study of outpatient warfarin patients comparing venous Stago INR to fingerstick INR on the Coagsense and Coagucheck XS POC meters. Patients were invited to study if they had an of INR 2.0 to 5.0 and had a medical history of antiphospholipid syndrome, hypercoagulable disorder, autoimmune condition, peripheral vascular disease, mechanical heart valve, atrial fibrillation, or deep vein thrombosis/pulmonary embolism/cerebrovascular accident history. Results: Seventy-seven patients were enrolled. Coagsense correlated well (92% of INRs within 20% of Stago, 64% of INRs within 0.2 of Stago, overall INR bias of 0.1 or 4%). Six patients had greater than 20% POC INR bias, which could have resulted in 4 warfarin dosing errors. Coagucheck XS INRs correlated poorly (49% within 20% of Stago, 10% of INRs were within 0.2 of Stago, overall INR bias of 0.66 or 25.7%). Forty-one patients had greater than 20% POC INR bias in all diseases, which could have resulted in 28 warfarin dosing errors. The average Coagucheck XS INR bias (0.46-1.3 INR) increased with each 0.5 increase in laboratory INR, whereas Coagsense bias remained stable (0.1-0.25) as INR increased up to 4.3. Two patients correlated well on Coagucheck XS but not Coagsense. Conclusion: Coagsense correlated better than Coagucheck XS and did not show increasing bias as INR increased. Both POC instruments had higher INR variability in 4 disease states (antiphospholipid syndrome, autoimmune, peripheral vascular disease, and hypercoagulable). Patient-specific laboratory correlations may be needed on each POC device.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 50 条
  • [1] Reliability of Point-of-Care International Normalized Ratio Testing in an Academic Family Medicine Clinic
    Christenberry, Emily J.
    Padilla, Margie E.
    Aguirre, Michelle
    Loya, Amanda M.
    Aragon, Lorenzo
    [J]. POINT OF CARE, 2018, 17 (02): : 55 - 58
  • [2] Point-of-care versus laboratory measurement of the International Normalized Ratio
    Pierce, MT
    Crain, L
    Smith, J
    Mehta, V
    [J]. AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2000, 57 (24) : 2271 - 2274
  • [3] Correlation of Point-of-Care International Normalized Ratio to Laboratory International Normalized Ratio in Hemodialysis Patients Taking Warfarin
    Hoel, Robert W.
    Albright, Robert C.
    Beyer, Lisa K.
    Santrach, Paula J.
    Magtibay, Donna L.
    Everson, Stephanie L.
    McBane, Robert D.
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 (01): : 99 - 104
  • [4] Point-of-care testing of the international normalized ratio in patients with antiphospholipid antibodies
    Perry, SL
    Samsa, GR
    Ortel, TL
    [J]. THROMBOSIS AND HAEMOSTASIS, 2005, 94 (06) : 1196 - 1202
  • [5] Evaluation of point-of-care International Normalized Ratio in sickle cell disease
    Rahman, Syeda
    Srisuwananukorn, Andrew
    Molokie, Robert E.
    Gowhari, Michel
    Njoku, Franklin
    Hussain, Faiz Ahmed
    Lee, James
    Nutescu, Edith A.
    Gordeuk, Victor R.
    Saraf, Santosh L.
    Han, Jin
    [J]. RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2021, 5 (04)
  • [6] Correlation of prehospital point-of-care international normalized ratio to laboratory-based international normalized ratio in acute traumatic coagulopathy
    Bodnar, Daniel
    Parker, Lachlan
    Meister, Matthew
    Ryan, Glenn
    Rashford, Stephen
    Wullschleger, Martin
    Lam, Alfred K.
    Bosley, Emma
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2022, 92 (06): : E127 - E131
  • [7] International normalized ratio testing with point-of-care coagulometer in healthy term neonates
    Shigeo Iijima
    Toru Baba
    Daizo Ueno
    Akira Ohishi
    [J]. BMC Pediatrics, 14
  • [8] Accuracy and Precision of Point-of-Care International Normalized Ratio in Patients With Liver Disease
    Shadlyn, Tevyn
    Bauman, Mary
    Tandon, Puneeta
    Yap, Jason
    Kawada, Patricia
    [J]. JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2023, 76 (06): : 704 - 709
  • [9] Comparison of two point-of-care international normalized ratio devices and laboratory method
    Vazquez, Sara R.
    Fleming, Ryan P.
    Johnson, Stacy A.
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 2017, 28 (07) : 534 - 539
  • [10] Inaccuracy of Point-of-Care International Normalized Ratio in Rivaroxaban-Treated Patients
    Baruch, Lawrence
    Sherman, Olga
    [J]. ANNALS OF PHARMACOTHERAPY, 2013, 47 (09) : 1210 - 1212