High-intensity focused ultrasound (HIFU) ablation by frequency chirp excitation: reduction of the grating lobe in axial focus shifting

被引:9
|
作者
Wang, Mingjun [1 ]
Zhou, Yufeng [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
关键词
high-intensity focused ultrasound; phased array transducer; grating lobe; frequency chirp excitation; axial focus shifting; temperature elevation; thermal dose; PHASED-ARRAY TRANSDUCER; MEDICAL ULTRASOUND; TISSUE ABLATION; FIELD; SURGERY; SIGNALS; PATTERN; DESIGN;
D O I
10.1088/1361-6463/aacaed
中图分类号
O59 [应用物理学];
学科分类号
摘要
High-intensity focused ultrasound (HIFU) ablation has gained popularity in tumor treatment. However, the pre-focal heating due to the presence of the grating lobe may generate unintended heating in clinical applications and limit the steering abilities of the phased array design. In order to solve this problem, frequency chirp excitation was proposed and evaluated both numerically and experimentally. First, propagation of an HIFU burst through multi-layer media was simulated in a nonlinear acoustic model using the angular spectrum approach. Influences of axial focus shifting on the acoustic intensity at the both grating and main lobes at different excitation frequencies were investigated. It was found that different excitation frequencies result in variations in the position and magnitude of the grating lobe in the pre-focal region, but have little influence on the main lobe. Thus, the frequency chirp excitation can spread the acoustic energy in the pre-focal region, and subsequently reduce the temperature elevation. The performances of downward and upward frequency chirps in different sweeping times were compared to those of conventional excitation at the constant frequency. Then, HIFU plane ablation was evaluated. Even without the cooling time between treatment spots when using the frequency chirps, the pre-focal heating was still less than that at the constant frequency. Finally, the thermocouple measurement in the gel phantom showed an similar to 40% reduction in pre-focal temperature elevations produced by a single-element concave HIFU transducer using the frequency chirps. Altogether, the frequency chirp excitation could effectively reduce the pre-focal grating lobe at a large axial focus shifting distance, which may enhance both the efficacy and safety of clinical HIFU ablation.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] High-intensity focused ultrasound ablation of breast cancer
    Wu, Feng
    ter Haar, Gail
    Chen, Wei R.
    EXPERT REVIEW OF ANTICANCER THERAPY, 2007, 7 (06) : 823 - 831
  • [42] Ultrasound-Guided High-Intensity Focused Ultrasound (HIFU) Treatment of Breast Fibroadenoma
    Kovatcheva, Roussanka
    Stoinov, Julian Ivanov
    Abehsera, Marc
    Seror, Bernard
    Guglielmina, Jean-Noel
    ANNALS OF SURGICAL ONCOLOGY, 2013, 20 : 52 - 52
  • [43] Ultrasound-guided High Intensity Focused Ultrasound (HIFU) ablation of placental vasculature
    Shaw, C. J.
    Civale, J.
    Giussani, D. A.
    Rivens, I
    ter Haar, G.
    Lees, C. C.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2015, 122 : 54 - 54
  • [44] Clinical Use of High-Intensity Focused Ultrasound (HIFU) for Tumor and Pain Reduction in Advanced Pancreatic Cancer
    Strunk, H. M.
    Henseler, J.
    Rauch, M.
    Muecke, M.
    Kukuk, G.
    Cuhls, H.
    Radbruch, L.
    Zhang, L.
    Schild, H. H.
    Marinova, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (07): : 662 - 670
  • [45] Single-session high-intensity focused ultrasound (HIFU) ablation for benign thyroid nodules: a systematic review
    Spartalis, Eleftherios
    Karagiannis, Sotirios P.
    Plakopitis, Nikolaos
    Theodori, Maria Anna
    Chrysikos, Dimosthenis
    Paschou, Stavroula A.
    Boutzios, Georgios
    Schizas, Dimitrios
    Spartalis, Michael
    Troupis, Theodore
    Nikiteas, Nikolaos
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (08) : 759 - 771
  • [46] High-intensity focused ultrasound (HIFU) in the treatment of localized prostate cancer. From total to focal ablation
    Aboyan, I. A.
    Pakus, S. M.
    Badyan, K., I
    Hasigov, A., V
    Galstyan, A. M.
    ONKOUROLOGIYA, 2020, 16 (03): : 153 - 164
  • [47] Significance of hyperechoic marks observed during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules
    Lang, Brian H. H.
    Woo, Yu-Cho
    Chiu, Keith Wan-Hang
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2675 - 2681
  • [48] Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours
    Wijlemans, J. W.
    Bartels, L. W.
    Deckers, R.
    Ries, M.
    Mali, W. P. Th. M.
    Moonen, C. T. W.
    van den Bosch, M. A. A. J.
    CANCER IMAGING, 2012, 12 (02): : 387 - 394
  • [49] Enhancement of ultrasound contrast agent in High-Intensity focused ultrasound ablation
    Wen Luo
    Xiaodong Zhou
    Xue Tian
    Xialong Ren
    Minjuan Zheng
    Kejun Gu
    Guangbin He
    Advances in Therapy, 2006, 23 : 861 - 868
  • [50] Enhancement of ultrasound contrast agent in high-intensity focused ultrasound ablation
    Luo, Wen
    Zhou, Xiaodong
    Tian, Xue
    Ren, Xialong
    Zheng, Minjuan
    Gu, Kejun
    He, Guangbin
    ADVANCES IN THERAPY, 2006, 23 (06) : 861 - 868