Enhancement of ultrasound contrast agent in High-Intensity focused ultrasound ablation

被引:0
|
作者
Wen Luo
Xiaodong Zhou
Xue Tian
Xialong Ren
Minjuan Zheng
Kejun Gu
Guangbin He
机构
[1] Fourth Military Medical University,Department of Ultrasound Xijing Hospital
[2] A & S Science Technology Development Co,undefined
[3] Ltd,undefined
来源
Advances in Therapy | 2006年 / 23卷
关键词
high-intensity focused ultrasound; ultrasound; contrast agent; therapeutic efficiency; coagulation;
D O I
暂无
中图分类号
学科分类号
摘要
High-intensity focused ultrasound (HIFU) is becoming an increasingly attractive modality for ablation. Enhancement of HIFU is an important issue that has been discussed and investigated worldwide. Ultrasound contrast agents are considered to constitute an efficient medium for changing acoustic characteristics and improving energy deposition in the focal region. The role of microbubbles in inducing enhanced heating, cavitation, and other related events in HIFU ablation has been investigated, with the goal of improving coagulation necrosis volume or decreasing acoustic power and exposure duration. Consequently, with the use of ultrasound contrast agents, applications of HIFU are expected to become more efficient, safe, and accurate and to produce fewer adverse effects. This paper reviews studies that have been conducted to investigate the enhancement of ultrasound contrast agents in HIFU ablation through experiments that were carried out in vitro and in vivo; an analysis of results of this enhancement mechanism is provided.
引用
收藏
页码:861 / 868
页数:7
相关论文
共 50 条
  • [1] Enhancement of ultrasound contrast agent in high-intensity focused ultrasound ablation
    Luo, Wen
    Zhou, Xiaodong
    Tian, Xue
    Ren, Xialong
    Zheng, Minjuan
    Gu, Kejun
    He, Guangbin
    [J]. ADVANCES IN THERAPY, 2006, 23 (06) : 861 - 868
  • [2] Controlled Hyperthermia With High-Intensity Focused Ultrasound and Ultrasound Contrast Agent Microbubbles in Porcine Liver
    Juang, Eric K.
    Koninck, Lance H. De
    Vuong, Kaleb S.
    Gnanaskandan, Aswin
    Hsiao, Chao-Tsung
    Averkiou, Michalakis A.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (08): : 1852 - 1860
  • [3] Enhancing ablation effects of a microbubble contrast agent on high-intensity focused ultrasound: an experimental and clinical study
    Cheng, C.
    Xiao, Z.
    Huang, G.
    Zhang, L.
    Bai, J.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 78 - 86
  • [4] Noninvasive Thermometry in High-Intensity Focused Ultrasound Ablation
    Zhou, Yufeng
    [J]. ULTRASOUND QUARTERLY, 2017, 33 (04) : 253 - 260
  • [5] Focal High-Intensity Focused Ultrasound Ablation of the Prostate
    Abrams, Lauren R.
    Koch, Michael O.
    Bahler, Clinton D.
    [J]. JOURNAL OF ENDOUROLOGY, 2021, 35 : S24 - S32
  • [6] High-intensity focused ultrasound ablation around the tubing
    Siu, Jun Yang
    Liu, Chenhui
    Zhou, Yufeng
    [J]. PLOS ONE, 2017, 12 (11):
  • [7] High-intensity focused ultrasound ablation of breast cancer
    Wu, Feng
    ter Haar, Gail
    Chen, Wei R.
    [J]. EXPERT REVIEW OF ANTICANCER THERAPY, 2007, 7 (06) : 823 - 831
  • [8] Microbubble contrast agent SonoVue combined with oxytocin improves the efficiency of high-intensity focused ultrasound ablation for adenomyosis
    Yao, Ruihong
    Zhao, Wei
    Gao, Bulang
    Hu, Jihong
    Wang, Tao
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 1601 - 1608
  • [9] Using microbubble contrast agent of different dosage to enhancing liver ablation induced by high-intensity focused ultrasound
    Li, Faqi
    Fu, Liyuan
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 39 - +
  • [10] Effect of high-intensity focused ultrasound on whole blood with and without microbubble contrast agent
    Poliachik, SL
    Chandler, WL
    Mourad, PD
    Bailey, MR
    Bloch, S
    Cleveland, RO
    Kaczkowski, P
    Keilman, G
    Porter, T
    Crum, LA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (06): : 991 - 998