关键词
high-intensity focused ultrasound; phased array transducer; grating lobe; frequency chirp excitation; axial focus shifting; temperature elevation; thermal dose; PHASED-ARRAY TRANSDUCER; MEDICAL ULTRASOUND; TISSUE ABLATION; FIELD; SURGERY; SIGNALS; PATTERN; DESIGN;
D O I
10.1088/1361-6463/aacaed
中图分类号
O59 [应用物理学];
学科分类号
摘要
High-intensity focused ultrasound (HIFU) ablation has gained popularity in tumor treatment. However, the pre-focal heating due to the presence of the grating lobe may generate unintended heating in clinical applications and limit the steering abilities of the phased array design. In order to solve this problem, frequency chirp excitation was proposed and evaluated both numerically and experimentally. First, propagation of an HIFU burst through multi-layer media was simulated in a nonlinear acoustic model using the angular spectrum approach. Influences of axial focus shifting on the acoustic intensity at the both grating and main lobes at different excitation frequencies were investigated. It was found that different excitation frequencies result in variations in the position and magnitude of the grating lobe in the pre-focal region, but have little influence on the main lobe. Thus, the frequency chirp excitation can spread the acoustic energy in the pre-focal region, and subsequently reduce the temperature elevation. The performances of downward and upward frequency chirps in different sweeping times were compared to those of conventional excitation at the constant frequency. Then, HIFU plane ablation was evaluated. Even without the cooling time between treatment spots when using the frequency chirps, the pre-focal heating was still less than that at the constant frequency. Finally, the thermocouple measurement in the gel phantom showed an similar to 40% reduction in pre-focal temperature elevations produced by a single-element concave HIFU transducer using the frequency chirps. Altogether, the frequency chirp excitation could effectively reduce the pre-focal grating lobe at a large axial focus shifting distance, which may enhance both the efficacy and safety of clinical HIFU ablation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Treatment of cornual pregnancy in a patient with adenomyosis by high-intensity focused ultrasound (HIFU) ablation A case report
    Yu, Lixia
    Xu, Linying
    Xu, Xiaoyan
    MEDICINE, 2017, 96 (48)
  • [22] Focus prediction of high-intensity focused ultrasound (HIFU) in biological tissues based on magnetic resonance images
    Dong, Zhaocheng
    Zheng, Huifeng
    Zhu, Qinfeng
    Wang, Yuebing
    APPLIED ACOUSTICS, 2022, 197
  • [23] Two sequential applications of high-intensity focused ultrasound (HIFU) ablation for large benign thyroid nodules
    Brian H. H. Lang
    Yu-Cho Woo
    Keith Wan-Hang Chiu
    European Radiology, 2019, 29 : 3626 - 3634
  • [24] Control parameters for high-intensity focused ultrasound (HIFU) for tissue ablation in the ex-vivo kidney
    Köhrmann, KU
    Michel, MS
    Steidler, A
    Marlinghaus, EH
    Kraut, O
    Alken, P
    AKTUELLE UROLOGIE, 2002, 33 (01) : 58 - 63
  • [25] Combination of Bubble Liposomes and High-Intensity Focused Ultrasound (HIFU) Enhanced Antitumor Effect by Tumor Ablation
    Hamano, Nobuhito
    Negishi, Yoichi
    Takatori, Kyohei
    Endo-Takahashi, Yoko
    Suzuki, Ryo
    Maruyama, Kazuo
    Niidome, Takuro
    Aramaki, Yukihiko
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2014, 37 (01) : 174 - 177
  • [26] Two sequential applications of high-intensity focused ultrasound (HIFU) ablation for large benign thyroid nodules
    Lang, Brian H. H.
    Woo, Yu-Cho
    Chiu, Keith Wan-Hang
    EUROPEAN RADIOLOGY, 2019, 29 (07) : 3626 - 3634
  • [27] The Efficacy of High-Intensity Focused Ultrasound (HIFU) in Advanced Pancreatic Cancer
    Bo Xie1 Jiajun Ling2 Weiming Zhang1 Xueqin Huang1 Jihua Zhen1 Yanzhe Huang1 1 Department of Oncology
    Chinese Journal of Clinical Oncology, 2008, (03) : 183 - 186
  • [28] Protocol for high-intensity focused ultrasound (HIFU) treatment of cutaneous neurofibromas
    Tang, Mimmi
    Karmisholt, Katrine Elisabeth
    Gillstedt, Martin
    Blakeley, Jaishri O.
    Roberts, Joshua
    Serup, Jorgen
    Bove, Torsten
    Peltonen, Sirkku
    JEADV CLINICAL PRACTICE, 2024, 3 (05): : 1723 - 1729
  • [29] High-intensity focused ultrasound (HIFU) for pancreatic carcinoma: evaluation of feasibility, reduction of tumour volume and pain intensity
    Marinova, Milka
    Rauch, Maximilian
    Muecke, Martin
    Rolke, Roman
    Gonzalez-Carmona, Maria A.
    Henseler, Jana
    Cuhls, Henning
    Radbruch, Lukas
    Strassburg, Christian P.
    Zhang, Lian
    Schild, Hans H.
    Strunk, Holger M.
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 4047 - 4056
  • [30] HIGH-INTENSITY FOCUSED ULTRASOUND (HIFU) THERAPY FOR UNRESECTABLE PANCREATIC CANCER
    Sofuni, Atsushi
    Asai, Yasutsugu
    Sano, Takatomo
    Mitsuru, Fujita
    Tsuchiya, Takayoshi
    Tsuji, Shujiro
    Tanaka, Reina
    Kamada, Kentaro
    Tonozuka, Ryosuke
    Honjo, Mitsuyoshi
    Mukai, Shuntaro
    Yamamoto, Kenjiro
    Matsunami, Yukitoshi
    Itoi, Takao
    GASTROENTEROLOGY, 2017, 152 (05) : S498 - S498