Focus prediction of high-intensity focused ultrasound (HIFU) in biological tissues based on magnetic resonance images

被引:6
|
作者
Dong, Zhaocheng [1 ]
Zheng, Huifeng [1 ]
Zhu, Qinfeng [1 ]
Wang, Yuebing [1 ]
机构
[1] China Jiliang Univ, Coll Metrol & Measurement Engn, Hangzhou 310018, Peoples R China
关键词
High -intensity focused ultrasound; Magnetic resonance imaging; 3D structural reconstruction; Focus predictions; SOUND FIELD; MR; PROPAGATION;
D O I
10.1016/j.apacoust.2022.108927
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High-intensity focused ultrasound (HIFU) is a non-invasive tumor treatment method that works by converting acoustic energy into heat and killing diseased cells at high temperatures in diseased areas of human tissue. The ability to accurately predict the HIFU focus has a direct impact on the safety and efficacy of the treatment procedure. At present the medical community mainly uses MR for guidance during HIFU procedures through temperature feedback and tissue displacement feedback. These systems perform poorly if one wishes to determine whether the HIFU focus is accurately focused on the target lesion prior to the start of treatment. A method is therefore proposed in this paper to accurately predict the HIFU focus in biological tissues. The method mines the mapping relationship between grey-scale information and acoustic parameters of magnetic resonance images of biological tissues from a novel perspective; after which the HIFU focus shift is predicted and experimentally validated. First, we performed MRI imaging on pork tissues (muscle, fat, and skin), and fitted a mathematical relationship between the grayscale of the magnetic resonance image and the acoustic parameters. Second, we reconstructed a 3D structural model of pork tissue based on magnetic resonance images. Third, we predicted the HIFU focus by combining k-Wave and 3D structural model. Finally, we performed actual experiments to measure the focal position of the HIFU sound field and compared it with simulation results. The comparison shows that the deviation between the focal point simulated by k-Wave and the actual measured focus is less than 0.30 mm on all acoustic axes in the X-, Y- and Z-direction, which falls within the acceptable range. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Shift of Focus Region (SFR) in Heated Tissues by High Intensity Focused Ultrasound (HIFU)
    Qian, Zu Wen
    Ye, Shigong
    Fei, Xingbo
    Zhu, Zhemin
    Jiang, Wenhua
    Yang, Yaqin
    Xiao, Ling
    CURRENT MEDICAL IMAGING REVIEWS, 2009, 5 (03) : 156 - 158
  • [2] Magnetic resonance imaging of the prostate following high intensity focused ultrasound (HIFU)
    Walkden, R.
    Illing, R.
    Amed, H.
    Allen, C.
    Emberton, M.
    Kirkham, A.
    BJU INTERNATIONAL, 2008, 101 : 19 - 19
  • [3] Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours
    Wijlemans, J. W.
    Bartels, L. W.
    Deckers, R.
    Ries, M.
    Mali, W. P. Th. M.
    Moonen, C. T. W.
    van den Bosch, M. A. A. J.
    CANCER IMAGING, 2012, 12 (02): : 387 - 394
  • [4] Prediction of high-intensity focused ultrasound (HIFU)-induced lesion size using the echo amplitude from the focus in tissue
    Zhou, Yufeng
    Gong, Xiaobo
    You, Yaqin
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, : 1349 - 1359
  • [5] High-intensity focused ultrasound (HIFU) therapy for pancreatic cancer
    Asai, Yasutsugu
    Sofuni, Atsushi
    Itoi, Takao
    Tsuchiya, Takayoshi
    Tsuji, Shujiro
    Kamada, Kentaro
    Tanaka, Reina
    Honjyou, Mitsuyoshi
    Mukai, Shuntaro
    Yamamoto, Kenjiro
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2016, 31 : 261 - 261
  • [6] High-intensity focused ultrasound (HIFU) for localized prostate cancer
    Uchida, T
    Minei, S
    Satoh, T
    Shimura, S
    Irie, A
    Hyodo, T
    Omata, T
    Baba, S
    Narendra, ST
    Thomas, GA
    Michael, KO
    JOURNAL OF UROLOGY, 2002, 167 (04): : 358 - 358
  • [7] Using the acoustic interference pattern to locate the focus of a high-intensity focused ultrasound (HIFU) transducer
    Wu, Chih-Ching
    Chen, Chiung-Nien
    Ho, Ming-Chih
    Chen, Wen-Shiang
    Lee, Po-Huang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (01): : 137 - 146
  • [8] Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU) in Treatment of Symptomatic Uterine Myomas
    Filipowska, Justyna
    Lozinski, Tomasz
    POLISH JOURNAL OF RADIOLOGY, 2014, 79 : 439 - 443
  • [9] Neurosurgical Applications of High-Intensity Focused Ultrasound with Magnetic Resonance Thermometry
    Colen, Rivka R.
    Sahnoune, Iman
    Weinberg, Jeffrey S.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2017, 28 (04) : 559 - +
  • [10] High-intensity focused ultrasound (HIFU) ablation by the frequency chirps: Enhanced thermal field and cavitation at the focus
    Wang, Mingjun
    Lei, Yisheng
    Zhou, Yufeng
    ULTRASONICS, 2019, 91 : 134 - 149